1, maximum 30atm, 20cc syringe
2, selok® patent technology
3, self-lock mechanism for gradual and rapid pressure release
4, precise monometer allows pressure reading accurate
Price term:exw/ cif/ fob
Cordis is a well-known medical device company that produces a variety of products, including devices used in interventional cardiology and vascular procedures. The Cordis Saber PTA balloon is likely designed for use in percutaneous transluminal angioplasty procedures. Angioplasty is a medical procedure used to open narrowed or blocked blood vessels, typically arteries, to improve blood flow. During angioplasty, a balloon catheter is inflated at the site of the blockage to widen the vessel and restore blood flow. Here are some general features you might expect from a PTA balloon like Cordis Saber: Balloon Material: The balloon is typically made of materials like polyethylene or polyurethane. Inflation System: It would likely have an inflation system that allows controlled inflation and deflation of the balloon during the procedure. Catheter Design: The balloon is mounted on a catheter, which is a flexible tube that allows the device to be threaded through blood vessels to the site of the blockage. Guidewire Compatibility: PTA balloons are often designed to be used with guide wires for precise placement.
Supplier: Hantech medical specializes in cdmo, covering balloon, catheter, infusion set, extension set, infusion gravity set as well as insulin syringe, insulin pen needles, automatic insulin injection pen, needle free connector, rubber stopper, rubber gasket, iv set components and iv set flow regulator. we also produces dental syringe, dental irrigator, plastic and silicone dental equipment, dental aligner components. we also manufacture silicon medical components, silicon rubber accessories, surgical masks, goggles, protective clothing and so on.
The EverFlex stent is designed for use in the treatment of peripheral arterial disease (PAD), specifically in the iliac arteries. Key features of the EverFlex Protege stent may include: Self-Expanding Design: The stent is self-expanding, meaning it can open and conform to the shape of the artery without the need for balloon inflation. Nitinol Construction: The stent is typically made of nitinol, a nickel-titanium alloy known for its flexibility and ability to maintain shape memory. Longitudinal Flexibility: The stent is designed to provide longitudinal flexibility, allowing it to adapt to the natural movement of the vessel. Iliac Artery Treatment: The EverFlex Protege stent is specifically indicated for use in the iliac arteries, which are located in the pelvis.
Made up of latex bonded with silicone elastomer eliminate the risk of encrustation. Sizes Adult (2 Way) : 12, 14, 16, 18, 20, 22, 24FG, Balloon Capacity: 30 ml Sizes Pediatric : Two way: 8, 10FG Balloon Capacity: 3 – 5 ml
Made up of 100% Silicone elastomer Sizes Adult (2 Way) : 12, 14, 16, 18, 20, 22, 24FG, Balloon Capacity: 30 m Sizes Pediatric : Two way: 8, 10FG Balloon Capacity: 3 – 5 ml
Foley Balloon Catheters have been carefully designed to ensure that the balloon materials, tips and fluid channel provide the best possible performance and the highest degree of comfort to patients while in use. SPM Medicare uses high quality medical grade materials to ensure bio-compatibility. Special precautions are taken to ensure balloon blockage and easy, trauma-free de-catheterization. The balloon is made of soft rubber material for better patient comfort. The symmetrical shape, when inflated, helps to maintain excellent retention of the catheter in the bladder. Special Features Blockage-free balloon Elliptical side eye Maximum fluid flow Trauma-free catheterization Colour-coded valve sleeve
Dk-ptca balloon catheter is ce1023 certificated, Pushability & torque transfer. 4. Optional-size balloon is designed for various Lesions. 5. Excellent lubricious coating for smoothly Delivery to the lesion. 6. Unique balloon refolding and trackability for Multiple dilatation. Sterile package
Developed for the treatment of mitral valve stenosis, the v-broaden ptmc balloon catheter is indicated for percutaneous transvenous mitral commissurotomy in patients with hemodynamically significant mitral valvular stenosis, resulting primarily from commissuralfusion of the mitral valve cusps. The v-broaden ptmc balloon catheter is manufactured of polyvinyl chloride with a balloon attached to the distal end. The balloon is consisted of two latex layers, between which is polyester micromesh. Product specification/models Specifications: 30mm/28mm/26mm/24mm/22mm/20mm. Eto sterilized, for single use. Shelf life is 2 years.
Optimal Eyes Smooth, optimal eyes ensuring atraumatic introduction and effective drainage. Pressure resistant balloon Ultra thin highly elastic balloon Easily Inflated or deflated for maximum patient safety. Large drainage lumen For fast and effective drainage Round channel that minimizes encrustation and clogging. Strong drainage funnel Kink resistance and Provided best connection to drainage bag. Inflation Valve Choice of hard or Soft non-return Valve for trouble free inflation &deflation of balloon.