The innovative optical layout and state of art mono-chromator with high grade blazed holographic grating ensure accuracy. Its integrated
Design assures long term stability and durability.
The precisely aligned detector and quality deuterium and halogen lamps enhance the precision across the uv/vis spectrum starting from
190nm and into the near-infrared 1100nm.
Online software upgrade capability via internet(for stand-alone models).
Full a4 print-out of graphs and tables of results with popular inexpensive printers such as hp or epson deskjet.
Real-time clock for date and time stamping of results.
Large lcd display (320*240 dots matrix).
Specifications:
Model
Uv-1600 (new)
Optical system
Double beam (1200 lines/mm grating)
Wavelength range
190-1100nm
Band width
0.5/ 1.0/ 2.0/ 4.0 nm optional
Wavelength accuracy
±0.3nm
Wavelength repeatability
0.2nm
Photometric accuracy
±0.3%t
Photometric repeatability
0.2%t
Photometric display range
-0.3-3a, 0-200%t, 0-9999c
Stability
± 0.001a/h @ 500nm
Baseline flatness
±0.001a
Noise
±0.001a
Stray light
≤0.05%t @220nm, 360nm
Data output port
Usb
Printer port
Parallel port
Display
Lcd (320*240 dots )
Lamps
Deuterium lamp & tungsten halogen lamp
Detector
Silicon photodiode
Software
Uv pc software
Packing size & weight
625*430*206mm & 30kg
625*430*206mm & 30kg
Laminated glass is one kind of safety glass, and when glass breakage, glass fragments adhering to the interlayer, it can be against forced entry, and avoid fragment damage. Sentryglas plus (SGP ) laminated glass ,0.89mm/1.52mm/2.28mm The main character: Stronger Performance : SGP glass is five times harder than PVB laminated glass, SGP film can let glass keep the shape ,without fall down.� SGP is suitable to use in stairs, flooring and overhead glazing, laminated glass , with outstanding post-breakage resistance to creep and collapse. Higher Transparence:� SGP film yellow index is only 10-25% of clear PVB ,it is best choice for low iron laminated glass process. Flexible UV option : SGP is good at both UV transmitting option and as traditional UV blocking interlayer. ,it can be made in a specialty, high-UV transmittance sheet, extremely useful when designing controlled environments for many life species .
JHG offer 3-5mm from 90-98% LT glass with rectangular sizes, shape sizes for greenhouse,hobby glass house. JHG may offer different greenhouse glass items: Tempered low iron glass 91+ Tempered clear glass 89+ Tempered AR glass� 95+ Tempered diffuse glass with 30-75 Haze Greenhouse Glass Advantage: Durability, Glass is the strongest of all greenhouse materials Becautiful Appearance. High light transmission, high UV available Shatter-Resistant
Hard low E is produced by spraying a chemical material with Tin componds on the melting glass surface to form single layer of compound film with certain low emissivity function. Applicationï¼? Architecture:� curtain wall, facade, windows and doors Home appliance: micro oven, refrigerator Advantage: Improved energy efficiency Less UV Reduced condensation Specification: Glass Thickness: 3.2mm, 4mm, 5mm, 6mm, 8mm, 10mm, 12mm Max size:� 3300*8000mm Normal size:� 2134x3300mm, 2440x3300mm, Quality Standard: In accordance with CE, GB, AS/NIS 2208-1996
UV-VIS Spectrophotometer
This UV-Vis spectrophotometer is designed to meet high requirement for precision measurement in the research and production of organic chemistry, biochemistry, medical testing, food testing, environmental protection, water testing industry, etc.
Single Beam UV-VIS Spectrophotometer
ysis. The pc software is supplied as standard and offers additional functionality with preloaded methods for dna and protein analysis, as well as extensive post-measurement tools, unlimited results saving and easy export of data. The precisely aligned detector and quality deuterium and halogen lamps enhance the precision across the uv/vis 65mm & 35kg 860x660x465mm & 35kg
Metering mode: Double-beam C-t optical structure, blazed holographic grating, photomultiplier tube detection Wavelength range:190nm-1100nm Resolution:better than 0.15nm Spectro bandwidth:1.8nm Wavelength accuracy:0.3nm(with automatic wavelength calibration device.) Wavelength accuracy:
Specifications Wavelength range 190 to 1100nm Spectral bandwidth 1nm (190 to 1100nm) Wavelength display 0.1-nm increments Wavelength setting 0.1-nm increments (1-nm increments when setting scanning range ) Wavelength accuracy ¦0.1nm @ 656.1nm D2 ¦0.3nm (190 to 1100nm) Wavelength repeatability ¦0.1nm Stray light less than 0.02% NaI @ 220nm, NaNO2 @ 340nm less than 1.0% KCl @ 198nm Photometric system Double Beam Photometric range Absorbance: -4to4 Abs Transmittance: 0% to 400% Photometric accuarcy ¦0.002 Abs (0.5Abs) ¦0.004 Abs (1.0Abs) ¦0.006 Abs (2.0Abs) Photometric repeatability less than ¦0.001 Abs (0.5Abs) less than ¦0.001 Abs (1Abs) less than ¦0.003 Abs (2.0Abs) Baseline stability less than 0.0003 Abs/H @700nm (one hour after light source turned ON) Baseline flatness within ¦0.0006 Abs (190 to 1100nm,one hour after light source turned ON) Noise level within 0.00005 Abs RMS value (@700nm) Dimensions (W+D+H) 450(W) x 490(D) x 270(H) Weight 15kg Printers DPU, ESC/P, PCL printers, USB I/F Windows-compliant printers are available with USB memory and PC software Memory USB memory (option) Saved as text and UVPC file Performance for PC USB memory + UVProbe (standard) Win XP 15 Kg Fully thermocol packing