CUMMINS diesel gensets
Diesel engine:
Rated power:28-1200kw,
Four stroke,
Water cooling,
1500rpm;
Alternator:
3 phases and 4 wires,
Rated voltage:400/230v,
Frequency:50hz,
Cosf+:0.8,
Avr
1. Diesel Generator Set Data Set Type XG -100GF Rated Output 100KW/125KVA Rated Current 180A Rated Frequency 50Hz Start-up time 5~6(s) Power Factor 0.8(Lag) Genset Weight(kg) 1800 Dimensions(mm) (L, W, H) 2800, 1050, 1500 Rated Voltage 400/230V 2. Diesel Engine Data Diesel Engine Model 6BTA5.9-G2 Rated Speed 1500(r/min) Fuel Consumption 105g/kw.h Start battery voltage 24V DC starter Cooling Way Water-cooled Induction system Turbocharged and Intercooled Total lubrication system capacity 16.4L Total coolant capacity Dimensions 8 - 161L Cycle 4 stroke Number of cylinders 6 in line Speed mode Electronic governor 3. Alternator Data Brand Kepu/Siemens/Stamford/Marathon Dynamo Model TFW2-100-4/1FC2-224-4/UCI 274E/MP-100-4 Excitation Mode Brushless and self-encouragement Efficiency 95% Protection Level IP22-IP23 Number of phase and Access Act Three-phase four-wire Insulation Class H Overload (PRP)110% load can run 1h Automatic voltage regulator (AVR) D203, Buffering function with a sudden load increase Forms Brushless and self-encouragement, Self-cooling Measures to suppress the radio interference 4. Genset Electrical Performance Voltage regulation(%) 0.5(Stable ) +20~-15(Transient) Frequency regulation(%) 5(Stable) 5(Transient) Voltage fluctuation rate(%) 1 Frequency fluctuations rate (%) 0.5 Mutation load voltage stabilization time(S) 1 Load mutation frequency settling time(S) 1 Waveform Distortion(%) 5. Dimensions(mm) (L, W, H) 2800, 1050, 1500.
Model 6bta5.9-g2 Power of output/kva 125 Number of cylinder, bore stroke(mm) 6-102x120 Displacement (l) 5.88 Oil capacity (l) 16 Type of governor Electronic Dimension(lwh) (mm) 2300*800*1500 Net weight (kg) 1100
ModelMTAA11-G3 ConfigurationIn-line,4-stroke,4-valve,water-cooled AspirationTurbocharged and air to air inter-cooled Number of Cylinder,BoreStroke (mm)6-125147 Displacement (L)11 Compression Ratio15:1 Prime Power/Speed (kw/r/min)282/1500 Standby Power/Speed (kw/r/min)310/1500 Fuel consumption (g/kwh)â?¤210 Oil Capacity (L)39 Starting MethodElectric Dimension(LWH) (m)13608331068 Net weight (kg)940
Quick details Place of origin: chongqing, china (mainland) Brand name: yangke Model number: yk200gf-mta11 Output type: ac three phase Speed: 1500rpm Frequency: 50hz Rated power: 200kw Rated voltage: 400/230v Rated current: 362 Bore&stroke: 125x147mm Type of governor: electronic usage: construction, hotel, school, mine, etc Certification: ce, iso9001, sgs, gost, tuv, bv Advantages: small size, large power reserve, high reliability Options: silent, container, dust proof Color: as your request Warranty: 1 year or 1000 working hours Engine net weight: 2500kg Package dimension: 2900x980x1750mm Packaging & delivery Packaging details:bubble film or naked packing with plastic wrap. Delivery detail:within 7 days after deposit confirmed
Cummins diesel generator sets (25kva-2250kva) Specifications: 1) Output range:20kW (25kVA) - 1800kW (2250kVA) 2) Cummins Engine models:4B3.9-G2, 4BT3.9-G2, 4BTA3.9G, 6BT5.9-G1, 6BT5.9-G2, 6BTAA5.9-G, 6CTA8.3-G, 6CTAA8.3G, NTA855G1, NT855-GA, NTA855-G1A, NTA855-G2, NTA855-G4, NT855-G2A, NTAA855-G7, KTA19-G2, NTAA855-G7A, KTA19-G3, KTA19-G4, KTAA19-G5, KTAA19-G6, KTAA19-G7, KTA38-G2, KTA38-G2A, KTA38-G5, KTAA38-G9, KTA50G3, KTA50G8, QSK60G4 ,QSK60-G8 3) Alternator model: Megaton/ Stamford/(Excitation: Brush less) 4) Water-cooled 5) 8hours operation base fuel tank 6) 230 / 400V AC, 50Hz / 60Hz, 0.8pF three-phase and four wires 7) Voltage adjust range:6% 8) Steady State Voltage regulation:1% 9) Insulation class: H 10) Protection:IP23 11) Control panel consisting of: Emergency Stop button Voltmeter and selector switch Ammeter and selector switch Frequency meter Controller with selection for auto-start, manual-start and an automatic alarm system with following (and not restricted to) features: A)Start/Stop button B)Hour run meter C)Monitor engine temperature and provides shutdown protection D)Monitor engine speed and provides optional shutdown protection E)Monitor oil pressure or level and provides shutdown protection F)Alarm output for abnormal operation 12) Sound-proof / weather-proof canopy is available 13) Detailed specification will provide upon requested Nude packing
We have a stock of quality, low-life generators from the military ï?¬ CAT 3408 400kW ï?¬ CAT C-16 500kW ï?¬ CAT 3406 350kW (House type) ï?¬ Cummins VTA-28G5 500kW ï?¬ Cummins LTA-10 250kW (House Type) ï?¬ Cummins LTA-10 250kW ï?¬ Cummins NT85-G3 350kW ï?¬ Cummins NT85-G3 350kW (House type) ï?¬ Cummins NT85-G2 300kW Please study if it is suitable for your market.
Technical data Genset model 30gf Filter, fuel filter, oil filter The components of the genset (1) diesel engine; (2)generator; (3)generator; (4)control panel(with 320b controller); (5)silent box The accessories Wave pipe , curved pipe , muffler , accumulator and the connecting lines , shock-absorbing spacer , and data . Size: 1760*730*1250 Weight:850kg
1.Main technical data of genset 1.1ModelCcfj50j 2.2Model6bt5.9-gm83 2.3Prime power64kw 2.4Governor typeElectronic 2.5Configuration4 cycle , 6 cylinder in line 2.6Cooling methodBy heater exchanger 2.7Bore/stroke102¡¨¢120mm 2.8Displacement37.5 l 2.9Starting methodElectric 2.10Fuel consumption214g/kw.H 3. Main technical data of alternator Alternator is selected the new type brushless alternator designed by us marathon electric, which has a unique design, advanced structure, small size, light weight, excellent performance, reliable running and easy-to-use operation. 3.1BrandMarathon 3.2ModelMp-h-50-4 3.3Prime power50kw 3.4ConfigurationBrushless , self-exciting 3.5Prime voltage230v/400v 3.6Frequency50 hz 3.7Power factor0.8(lagging) 3.8Phase/wire3 phase 4 wires 3.9IsolationH Size: 1760*730*1250mm Weight: 900kg
Cummins is one of world top famous engines and widely acceptable all over the world. Kingte power cummins gensets are ranging from 25kva up to 1500kva. Cummins gensets are vastly used in transportation sector, buildings, telecom, schools, hospitals, ships, petrolube oil fields and industrial power supplying area etc. With cummins gensets reliability, durability, flexibility, energy-saving, environment protection and wonderful world wide after-service networks, cummins gensets act as a fundamental role in global gensets industry. (cummins generator, cummins diesel generator, cummins diesel genset, cummins generator set, cummins power generator, cummins generating set, cummins genset). 1) diesel engine: Kingte power cummins series diesel gensets are powered by cummins industrial diesel engines. These water cooled 4-stroke engines are completed with air, fuel and oil filters, electric starting and charging equipment. Low water level protection function is available. 2) alternator: Stamford, leroy somer, megaton, defeng kaijieli or equivalent alternators are adopted to couple cummins diesel engines. These self-excited, brushless and avr alternators have the following features: self regulating of voltage, water-proofed, h class insulation, rated in accordance with iec60034, protection capability conforming to standard of name1 and ip22/ip23. 3) power output ranging: 27kva to 1, 500kva 4) rated frequency: 50 or 60hz 5) rated speed: 1, 500rpm or 1, 800rpm 6) phase: 3 phase 4 wire & 1 phase 2 wire 7) ac voltage: 110v/120, 220v/240, 380v/415, 440/480 or other voltages required. 8) control system options: key start, automatic amf, ats, remote control, parallel system and synchronization system etc. Wood case