1. Perfect shock absorption can effectively avoid further injury to the wound.
2. Fasten the bandage applied.
3. It helps reduce scar tissue and can be cut to the size required for toes or fingers.
4. OEM and tailor-made services are available.
5. SIZE¡GS-15cm / 1.5cm
M-15cm / 2.0cm
L-15cm / 2.5cm.
Gel and Clot Activator Tube aims to obtain high quality serum specimen for biochemistry , immunology and serology tests in clinical inspection. Inside the tube there is some gel present at the bottom, which is a pure substance and is very stable in physico-chemistry properties. Otherwise, the gel can avoid high- temperature decomposition and small molecules precipitation, hence it greatly reduces the risk of testing equipment clogging.
Gel / Lotion - A wide variety of tubular gels - Tube lotion of various sizes and shapes CKN International introduces customized products for each customer and enables them to lead the market. We aim to satisfy customers by segmenting and specializing research and development work on nail art products such as gel polish, color gel, top gel, base gel, clear gel, gel remover, gel cleaner, and acrylic powder. In addition, through partnerships with various partners on nail art products such as gel polish containers, caps, brushes, cosmetics containers, gel brushes, files, and gel lamps, we are enhancing our product competitiveness with price and technology.
LYBCON Vacutainer GEL-SST Advance tubes During the centrifugation of the LYBCON Vacutainer GEL-SST Advance tubes, an inert LYBCON Vacutainer gel separates the serum and the blood clot preventing the contamination of the serum from the separated cellular components. For example, the serum for certain analytes such as potassium, phosphorus and glucose must be separated from the cells within a few hours - otherwise the results will be significantly distorted. Using LYBCON GEL-SST Advance tubes routine analyses in clinical chemistry such as potassium and glucose are still stable after a week of storage at 2-8 C. Clinical evaluations of special chemistry demonstrate a high degree of analyte stability with the acrylic gel in the LYBCON GEL-SST Advance, with detection of >90% of the therapeutic drugs and other special analytes(proteins/peptides, steroids and vitamins) tested. As a result of the type of gel used in the GEL-SST Advance tubes, LYBCON Vacutainer short centrifugation times of 5 minutes at 3000g can be achieved. The stability of the gel barrier is a distinct advantage during transport and storage. The main advantages of gel tubes versus non-gel tubes are: Stable barrier between serum and clotted blood, therefore better analyse stability. Better sample quality. Optimisation of the work flow: Short centrifugation time, sample processing and archiving in the primary tube. No possibility of misidentification due to the use of secondary tubes. CLOTTING TIMES The minimum recommended coagulation time for GEL-SST Advance tubes for patients who have not LYBCON Vacutainer received anticoagulation treatment is 30 minutes. CENTRIFUGING CONDITIONS 1600-2000g for 10 minutes MIXING RECOMMENDATION Serum Separation Tubes should be gently inverted 180 and back 6-8 times. EFFECTS OF TEMPERATURE LYBCON Vacutainer GEL-SST Advance should be stored at 4-25C and protected from direct sunlight during storage. Cooling of the tube by or during centrifuging can affect the movement capability of the gel. The optimum separation of serum and coagulated blood is achieved at a temperature of 20-25C. Serum Separation Tubes should be gently inverted 180 and back 6-8 times. CLOT ACTIVATOR LYBCON Vacutainer GEL-SST Advance tubes contain silica particles. SPECIFICATION Specimen: Serum Additive: Gel & Clot Activator Cap color: Dark yellow Tube Size: 13x75mm Draw Volume: 3.5mL Max. draw volume Tolerance: ±10%
Alcohol & Gel tube
CE&ISO certified professional manufacturer of medical supplies lab consumables vacutainer since2009-Hebei Chaoran Medical Instruments Vacuum blood collection tubes are applicable to the clinical blood test and the blood cells analysis The internal walls of the tubes are coated with different additives designed to stabilize and preserve the specimen prior to analytical testing *Red: Non-additive - Serum *Red: Clot Activator-Serum *Yellow: Gel & Clot Activator -Serum *Purple: ETDA K2 / ETDA K3 - Whole blood *Black: 3.8% Sodium Citrate (1:4)- Whole blood *Blue: 3.2% Sodium Citrate (1:9)- Whole blood or Plasma *Green: Lithium Heparin / Sodium Heparin-Plasma *Grey: Glucose - Plasma Material:PET plastic or Glass Tube size :13*75mmï¼?13*100mm Volume:1ml,2ml,3ml,4ml,5ml,6ml,7ml Etc Shelf Life:2years Disinfecting Type:gamma ray Sterilized:yes Band:Chaoran Sample:Availible OEM:Available Certificate:CE/ISO
High-quality 50ml PVC tube ----- Recipe according to WHO guidelines; 80% alcohol ----- Recipe content (based on 10L container): 8333 ml Ethanol 96%; 417 ml Hydrogen peroxide 3 %; 145 ml Glycerol 98 %; 1105 ml Purified water.----- Our hand disinfectant is manufactured according to the WHO guidelines of 2010 for the local manufacture of ABHs (alcohol-based hand scrubs). ----- According to the WHO, it offers a broad antimicrobial spectrum, a fast antimicrobial effect and good skin tolerance. Keep away from children. ----- EN 14476
This balancing bath gel with Aloe vera extract provides a mild cleansing leaving the skin feeling soft and tender.
Also known as Serum separating tubes Gel separates the serum and the blood clot during centrifugation of the GEL-SST Advance tubes, preventing the serum from being affected by the separated cellular components. Material: PET & PP Type of Additive: Silicone Gel & clot activator Size: 13X75 mm, 13X100mm Capacity: 3.5mL, 4mL, 5mL, 6mL Available in: Vacuum and Non-Vacuum Colour Code: Yellow Available Packaging: Inner Packaging 100 pieces, Outer Carton Packaging 1200 pieces Used for: Endocrinology, Toxicology, Microbiology, Immunology & urea test C reactive protein test * Serum Separation Tubes should be gently inverted 180 and back 6-8 times
CE&ISO certified manufacturer of medical supplies medical lab consumables+8613930205358 Product name: blood collection tube Type:Vacuum or non vacuum,micro blood collection tube Spec: Gel+clot activator tube,plain tube/no additive tube, clot activator tube,sodium heparin/lithium heparin tube,PT tube/3.2% sodium citrate tube,edta k3k2 tube,ESR tube,glucose tube Cap Color:purple/Lavender/Red/Yellow/Blue/Green/Gray/Black Material:PET plastic or Glass Tube size :13*75mm,13*100mm Volume:1ml,2ml,3ml,4ml,5ml,6ml,7ml Etc Shelf Life:2years Disinfecting Type:gamma ray Sterilized:yes Brand:Chaoran Sample:Availible OEM:Available Certificate:CE/ISO