Features:
1. Steady power, high efficiency and negligible heat generation.
2. Digitally controlled, automatic frequency tracking
3. High strength alloy scaling tip
4. Ergonomic design
5. High quality and durable cable.
6. Titanium alloy axis
7. Full spectrum power range
8. Exquisite craft work, small and light
9. Detachable Handpiece
10. Can be autoclaved at 135 centigrade and 0.22MPa.
Technical information:
1. Adapter input: 110V~230V ~ 50/60Hz
2. Main unit input: 24V ~ 50/60Hz
3. Input power: lower than 40VA
4. Main unit fuse: 250V/T 1AL
5. Output power: 3W to 20W
6. Primary tip vibration excursion: lower than100um
7. Tip vibration frequency: 28kHz
8. Half-excursion force: lower than 2N
11. Water pressure: 0.01MPa~0.5MPa(0.1bar to 5bar)
12. Gross Weight: 2.2Kgs
13. Net weight: 1.85Kgs
Adopt ceramic transducer. Automatic frequency trace. 5 tips. 220v 50hz, 2.1kg.
Ultrasonic Scaler Tooth Cleaning 8W Calculus Remover Stains Tartar Scraper High Frequency Vibration Specifications: Product Name Digital Ultrasonic Scaler Product Model PUS-T01 Product Size L200*W49*H32mm Product Weight 125G Packing Size L238*W106*H43mm Material ABS Battery Spec: 2000 mAh Lithium Rated Power 8W Adapter Voltage 5V Ultrasonic Frequency 40khz ±2khz Country of Origin China Package Included: 1 x UltraSonic Dental Scaler 1 x USB Charger 1 x User Manual Features 1.High quality alloy steel, easy to remove dental calculus, smoke stains and tea stains. 2.Ultrasonic high frequency vibration enables to erase leftovers or food debris on the teeth effectively. 3.Two adjustable vibrating speed levels meet your different cleaning needs. 4.Rechargeable battery design, USB for easy charging, convenient to carry anywhere. 5.IPX6 waterproof grade, more convenient for teeth cleaning use.
New TLC E-Generator Fiber Optic Hand piece Traditional fiber optic hand piece cannot work without wire. Now our revolutionary new product TLC E-Generator Fiber Optic Hand piece brings light without wire. This Hand piece has an internal Air-Driven Generator, which supplies fiber optic to light the tip of the hand piece. New TLC E-Generator Fiber Optic Hand piece high performance 25,000 LUX. It also offers triple water spray. Improving visibility and cooling where you need it. 1. Super torque, standard head, mini head 2. 2 Hole/ 4 holes 3. Triple water spray 4. Fibre optic handpice with Air-driven generator inside; 5. Push button 6. Ceramic bearing 7. Noise Level: less than 70dB 8. Net weight: 88g 9. Torque head height 12.55 mm 10. Torque head diameter 14.4 mm 11. Air pressure: 250-300kpa 12. Rotation speed: 310, 000-350, 000 RPM
Older generation low speed straight hand piece rolls over on a table top easily, and the new design prevents that and makes the hand piece stays put where you put it. TLC Brand New Style Dental Low Speed Hand piece complete Kit has all traditional features, with other higher capabilities and less weight. A great choice at lowest possible retail pricing. TLC straight hand pieces have the ergonomic triangular cross section which provides a comfortable and relaxing hold for prolonged clinical procedures. The following is other features of TLC Dental New Low Speed Dental Hand piece Complete Kit Features: TLC-L4N-AM -1: 1 Direct Drive -Midwest 4 hole -Max speed 22, 000 min-1 TLC-L4N-SH -For HP burs(2.35) -Non-Optic -Spray Nozzle TLC-L4N-CA -ISO E-Type External Water Spray -1: 1 Direct Drive -For CA burs(2.35) -Latch type -18,000 to 22,000 R.P.M adjustable -Spray nozzle
- comprehensive treatment of periodontal disease ; - painless supra-gingival scaling ; - sub-gingival scaling without harmful to enamel and cementum; - root canal preparation and flushing and etc Size:58¡á37¡á18cm Weight:7.0kg/unit
Supplier: Ultrasonic scaler
X-ray machine Technical parameter 1. The numbers of x-ray tubes used in the product are also used as product number and x-ray generator (bulb tube head) number. 2. The current and voltage of x-ray tubes are fixed in three groups, they are: X exposure voltageú¿kvpú¬ 60 65 70 X-ray currentú¿maú¬ 0.50 0.85 1.10 3. When adding up voltage, total current is less than 2a and total power is 500w 4. Drain current and earth resistance are in accordant with the stipulates in gb9706.1 5. The three groups of voltage (60kvíó65kvíó70kv) are adjustable. 6ú«wireless remote control in any angles within 10 meters part form the control box 7. The parameter of x-ray generator (bulb tube head) 7.1. The parameter of x-ray tubes A. Focus index: 0.3í-0.3mm2 Bú«the voltage of the-highest-voltage generator: 90kv C. The highest inverse peak voltage: 90kv D. Filament characteristic: vf=5ví+0.5vú¼if=3a E. Target surface obliquity: 12íp F. The cooling manner of bulb tube head: oil immersion 8.7.2 the parameter of x-ray generator (bulb tube head): A. Focus-skin distance: 200mm B. The thickness of filter-ray film: more than 1.5mmal C. The leakage rate of x-ray: no more than 0.002mgy/h (no. 29.204.3 in gb9706.12 prescript that the leakage rate of x-ray is no more than 0.25mgy/h) D. The manner of limiting beam: using planigraphic device
Technical parameter 1. The numbers of x-ray tubes used in the product are also used as product numbers and x-ray generator (bulb tube head) numbers. 2. The current and voltage of x-ray tubes are fixed in three groups, they are: X exposure voltage (kvp) 60 65 70 X-ray current (ma) 0.50 0.85 1.10 3. When adding up voltage, total current is less than 2a and total power is 500w 4. Drain current and earth resistance are in accordant with the stipulates in gb9706.1 5. The three groups of voltage (60kv, 65kv, 70kv) are adjustable. 6. Wireless remote control in any angles within 10 meters part form the control box 7. The parameter of x-ray generator (bulb tube head) 7.1. The parameter of x-ray tubes A. Focus index: 0.3í-0.3mm2 B. The voltage of the-highest-voltage generator: 90kv C. The highest inverse peak voltage: 90kv D. Filament characteristic: vf=5ví+0.5v, if=3a E. Target surface obliquity: 12íp F. The cooling manner of bulb tube head: oil immersion 7.2 the parameter of x-ray generator (bulb tube head): A. Focus-skin distance: 200mm B. The thickness of filter-ray film: more than 1.5mmal C. The leakage rate of x-ray: no more than 0.002mgy/h (no. 29.204.3 in gb9706.12 prescript that the leakage rate of x-ray is no more than 0.25mgy/h) D. The manner of limiting beam: using planigraphic device
1. Fight gingivitis, periodontal diseases and bacteria with the revolutionary pulsating water jet. 2. Cleans your bridgework, crowns, braces and implants effortlessly. 3. Removal of plaque & reduction of gingival bleeding. 4. Safe & effective on patients with diabetes and orthodontic appliances. 5. Ergonomically-designed spooned shape jet removes tongue bacteria with pulsating sprays, putting and end to bad breath. 6. Nasal irrigator clears your sinuses with added benefits that include reducing. Allergies, sinusitis, post nasal drip, snoring caused by nasal congestions, smog, smoke or chemical exposure, and dry inflamed membranes. 7. Can be used with water, mouth wash or even anti-bacterial rinses. Color box pack, 12pcs/master carton -gb size:14.0 x 8.2 x 27.5cm -carton size:30.0 x 51.2 x 31.6cm -n.W/ctn:3.9kg -g.W/ctn:6.7kg