Feature
1.Adopting straight-action diaphragm sructure without pressure starting enlarges its applicable scopes.
2.Adopting plate diaphragm structure with reliable start and close lengthens the service life of the product.
3.Selecting plastic sealed coil improves the safe application of this product under many environments.
Tai-shing is a professional manufacturer of solenoid, valve, water solenoid valve, sensor, soap dispenser, relay, ssr. We also provide solenoid odm/oem service to customers from worldwide.
TX Plunger solenoid valves are direct or servo operated solenoid valves for liquid, suction, and hot gas lines with fluorinated refrigerants.
TX Plunger solenoid valves are direct or servo operated solenoid valves for liquid, suction, and hot gas lines with fluorinated refrigerants.
òNumerous Variants A room for customization at a reasonable cost is the description that sums up the KOFLOC Standard Mass Flow Controller MODEL 3660 SERIES. The MODEL 3660 SERIES has gained wide acceptance and solid reputation for its flexibility. It is in use throughout laboratories, universities and foundries, in both its original and customized variants. ò Low-Cost If the cost effectiveness is the decisive factor in choosing the right mass flow controller for you application, few can compete with the KOFLOC Standard Mass Flow Controller MODEL 3660 SERIES. Its extensive menu of standardized optional features is yet another advantage in cost considerations. ò KOFLOC Dependability KOFLOC has 60 years of experience in manufacturing precision flow instruments. KOFLOC products, both standard and off-catalog custom items are well received throughout Japan as the name that manifests confidence. KOFLOC, the fluid expert, is the name professionals trust in precision control of minute flow. ò Low Pressure Option The KOFLOC Standard Mass Flow Controller MODEL 3660 SERIES has a standard low-pressure differential option especially suited for applications of burn control. ò Solenoid Valve The KOFLOC Standard Mass Flow Controller MODEL 3660 SERIES utilizes the unidirectional normally closed valve with solenoid actuator to achieve higher dependability and safety. ò Standardized Dimensions and Parts The KOFLOC Mass Flow Controller, MODEL 3660 SERIES retains the standard 3 in (76 mm) footprint, regular fittings and SEMI standard serial connector to easily replace and fit into existing gas lines without any modifications for use in widest possible applications. òQuick Response The KOFLOC Mass Flow Controller, MODEL 3660 SERIES is equipped with the new improved constant current thermal differential sensor for quick response of 0 ~ 100% in 2 s or less. ò Versatility The KOFLOC Mass Flow Controller, MODEL 3660 SERIES is in use as a component for Sputter deposition, bond wiring, welding and washing equipment for semiconductor and electronic industries. It is used in scientific and analytic purpose such as in thermal analysis and vacuum equipment. The MODEL 3660 is also capable of meeting unique needs as the mass flow controller in industrial applications, including gas mixing, air sampling, burn control and more.
PK diaphragm solenoid valve is an automatic control parts used in refrigeration system to control the refrigerant to pass or not pass, the valve is widely used in compressor group, central air-conditioning, cold storage equipment and bus air-conditioning system
Step-by-step direct-acting solenoid valve Principle: It is a combination of direct motion and pilot type. When there is no pressure difference between the inlet and the outlet, after energization, the electromagnetic force directly lifts the pilot small valve and the main valve closing member upward, and the valve opens. When the inlet and outlet reach the starting pressure difference, after the energization, the electromagnetic force leads the small valve, the pressure of the lower chamber of the main valve rises, and the pressure of the upper chamber drops, so that the main valve is pushed upward by the pressure difference; when the power is off, the pilot valve uses the spring The force or medium pressure pushes the closure and moves down to close the valve. Features: It can also be operated at zero pressure difference or vacuum or high pressure, but the power is large, and it must be installed horizontally. Pilot solenoid valve Principle: When energized, the electromagnetic force opens the pilot hole, the pressure in the upper chamber drops rapidly, and a pressure difference between the lower part and the lower part is formed around the closing member. The fluid pressure pushes the closing member upward to move the valve to open; when the power is off, the spring force leads the pilot. The hole is closed, and the inlet pressure passes through the bypass hole. The rapid chamber forms a lower high and high pressure difference around the valve closing member, and the fluid pressure pushes the closing member downward to close the valve. Features: The upper limit of the fluid pressure range is high, can be installed arbitrarily (customized), but must meet the fluid pressure difference conditions. 2, the difference between the solenoid valve from the valve structure and material and the principle, divided into six sub-categories: direct-moving diaphragm structure, step-by-step direct diaphragm structure, pilot diaphragm structure, direct-acting piston structure, Step-by-step linear motion piston structure and pilot piston structure. 3. Solenoid valves are classified according to their functions: water solenoid valve, steam solenoid valve, refrigeration solenoid valve, low temperature solenoid valve, gas solenoid valve, fire solenoid valve, ammonia solenoid valve, gas solenoid valve, liquid solenoid valve, miniature solenoid valve, Pulse solenoid valve, hydraulic solenoid valve normally open solenoid valve, oil solenoid valve, DC solenoid valve, high pressure solenoid valve, explosion-proof solenoid valve, etc.
Features and Benefits Wider EPDM seat design, replaceable, its suit for different type of flanges. ISO5211 standard top flange, suit for different operations. Eccentric pin on the stem, not destroy structure of the stem, make sure the safety and strongth. Lever operation BWLX: DN50~DN150. Applicable Standards Design standard: BS5155, EN593, API609 Flange standard: BS EN1092-2 Top flange standard: ISO5211 Face to face standard: BS EN558-1 Pressure test standard: BS EN12266-1, API598 Technical Data Nominal diameter:DN50~DN150(2"~6") Nominal pressure: PN16 Working temperature: -5C ~ +85C Sealing test:1.1PN Shell test:1.5PN Suitable for: Water, ethylene glycol, non correction medium, etc.
Supplier: 2W series solenoid valves, 2WB series solenoid valves
Supplier: Solenoid valves