Type: k
Color code: ansi mc 96.1
Conductor: 30awg solid
Insulation:pfa -75 ~ +260 degree c
Jacket:pfa -75 ~ +260 degree c
200m/roll
Type: j class 1 Color code: ansi mc 96.1 Conductor: 30awg solid*1 pair Insulation:pfa -75 ~ +260 degree c Jacket: pfa -75 ~ +260 degree c 200m/roll
ESP Cable Solutions Co., Limited(ESPCS) exporting more than 20 million feet of Thermocouple wire and 30 million of PTFE insulated wire(Nickel Plated Copper and other types) to North America market every year. The main reason is because our products have excellent performance and very outstanding advantages, the advantages as below for your reference. 1.The production process we use PTFE tape wrapped and fused process, which not only ensures excellent performance but it is also can proof moisture. 2.We can make 20,000ft wire in a continuous length without any splices. 3.The PTFE wires are tested to withstand temperatures up to 330 Degree Celsius. Type: 24AWG Type-K Thermocouple Wires, 20000ft per Spool
ESP Cable Solutions Co., Limited(ESPCS) exporting more than 20 million feet of Thermocouple wire and 30 million of PTFE insulated wire(Nickel Plated Copper and other types) to North America market every year. The main reason is because our products have excellent performance and very outstanding advantages, the advantages as below for your reference. 1.The production process we use PTFE tape wrapped and fused process, which not only ensures excellent performance but it is also can proof moisture. 2.We can make 20,000ft wire in a continuous length without any splices. 3.The PTFE wires are tested to withstand temperatures up to 330 Degree Celsius. Type: 28AWG Thermocouple Wires & Cables, 20000ft per Spool
NiCr-NiSi(Type K) thermocouple finds the widest use in all basemetal thermocouple, at temperature above 500ã??The main chemical composition of positive leg NiCr (KP) are Ni~90% and Cr~10%; negative leg NiSi (KN) are NiÃ?97% and Cr~3%. The operating temperature range is -200~1300(for short term) and 0~1100( for long term)ã?? Type K thermocouple has strong resistance to oxidation than other base metal thermocouples. It has high EMF against Platinum 67, excellent temperature accuracy, sensitivity and stability, with a low cost. It is recommended for oxidizing or inert atmospheres, but cannot be used directly in the following cases: (1) Alternatively oxidizing and reducing atmosphere, (2) Atmosphere with sulphur gases (3) Long time in vacuum (4) Low oxidizing atmosphere such as hydrogen and carbon monoxide atmosphere
We are a leading Chinese manufacturer and supplier of Nickel Alloy wire and Iron Chrome Aluminium Alloy wire, our main products cover Thermocouple Wire Type K, J, E, T and N, Alloy 11 wire, Kanthal D, Kanthal A-1, NiCr80/20, NiCr60/16, Nickel 200, Nickel 201, Constantan, Manganin etc. Wound on plastic spools
K type thermocouple wire with FEP insulation The thermocouple compensation cables can also be termed as instrumentation cables, since they are used for process temperature measurement. The construction is similar to pair instrumentation cable but the conductor material is different. Thermocouples are used in processes to sense temperature and is connected to the pyrometers for indication and control. The thermocouple and pyrometer are electrically conducted by thermocouple extension cables / thermocouple compensating cables. The conductors used for these thermocouple cables are required to have similar thermo-electric (emf) properties as that of the thermocouple used for sensing the temperature. Our plant mainly manufacture type KX,NX,EX,JX,NC,TX,SC/RC,KCA,KCB compensating wire for thermocouple, and they are used in temperature measurement instruments and cables. Our thermocouple compensating products are all made abiding by GB/T 4990-2010 'Alloy wires of extension and compensating cables for thermocouples' (Chinese National Standard), and also IEC584-3 'Thermocouple part 3-compensating wire' (International standard). Insulation material and color can be custom made as per your request.
Type: k Ansi code Diam.: 24awg solid Insulation: glassfiber 482 degree c Jacket: glassfiber 482 degree c 200m/roll
The thermocouple compensation cables can also be termed as instrumentation cables, since they are used for process temperature measurement. The construction is similar to pair instrumentation cable but the conductor material is different. Thermocouples are used in processes to sense temperature and is connected to the pyrometers for indication and control. The thermocouple and pyrometer are electrically conducted by thermocouple extension cables / thermocouple compensating cables. The conductors used for these thermocouple cables are required to have similar thermo-electric (emf) properties as that of the thermocouple used for sensing the temperature. Our plant mainly manufacture type KX,NX,EX,JX,NC,TX,SC/RC,KCA,KCB compensating wire for thermocouple, and they are used in temperature measurement instruments and cables. Our thermocouple compensating products are all made abiding by GB/T 4990-2010 'Alloy wires of extension and compensating cables for thermocouples' (Chinese National Standard), and also IEC584-3 'Thermocouple part 3-compensating wire' (International standard).
Supplier: Thermocouple wire & cable, thermocouple connector, thermocouple
Buyer: Thermocouple wire & cable, thermocouple connector, thermocouple