Five para monitor (spo2/ecg/nibp/resp/temp), 7 waveform display, 10.4" high resolution TFT screen, upgradable to IBP & ETCO2.
8 kg gross
Ecg, nibp, spo2, resp, temp, hr/pr
Multipara Monitor
Nibp Method oscillometry Modes manual / auto / continuous Method ra-ll impedance Range adult: 0-120rpm;pediatric/neonatal: 0-150rpm Apnea alarm yes Optional Etco2, ibp, printer & networking Ecg Lead mode 3-iead or 5-lead Lead selection i, ii, iii, avr, avl, avf, v Heart rate range ● adult: 15-300bpm ● ped/neo 15-300bpm Ecg waveform 2 channals Accuracy ±1 bpm or±1 %, whichever is greater S-t segment detection: measurement range 0.2mv~2.0mv
Ecg Lead mode: 5 leads or 3 leads Lead selection: i, ii, iii, avr, avl, avf, v, Gain: ´2.5mm/mv, ´5.0mm/mv, ´10mm/mv, ´20mm/mv, auto Resparation Method: impedance between r-f(ra-ll) Bandwidth: 0.3 ~ 2.5 hz Resolution: 1 rpm Accuracy : ±2 rpm Apean alarm: 10 ~ 40 s Spo2 Measuring range: 0 ~ 100 % Alarm range: 0 ~ 100 % Resolution: 1 % Accuracy ● 70% ~ 100% ±2 % ● 0% ~ 69% unspecified Actualization interval: about 1 sec. Alarm delay: 10 sec. Temperature Channel: 2 Measuring and alarm range: 0 ~ 50 °c Resolution: 0.1°c Accuracy : ±0.1°c Range ● adult: 15 ~ 300 bpm ● neo/ped: 15 ~ 350 bpm Accuracy : ± 1% or ± 1bpm, which great Resolution: 1 bpm Diagnostic: 0.05 ~ 100 hz Calibration signal: 1 (mv p-p), accuracy:±5% St segment monitoring range: measure and alarm -2.0 ~ +2.0 mv
Flexible Extension Interface, Free Selection. 12.1 High Brightness long-life LED Display. Light Weight and Slim Design. Iconify ley operation, Centralized Menu maker it easier and faster to use. One-key switch and identing key menu save more display Space. Exquisite and Convenience. Optional Functions: IBP, EtcO2, Nellcore & Masimo Spo2, Suntech NIBP, Touch, HDMI, WIFI, Central Station S/W, Scanning Gun, Card reader and information input module, etc.
Standard parameter: ecg, resp, nibp, spo2, temp, pr. 12.1" large-screen color tft display 7-lead ecg waveforms display , big font observational interface Reviewable ecg waveforms, maximum 72 hours reviewing graphic trends Digital spo2 technique, precise measurement for weak perfusion and finger shaking Arrhythmia and s-t segment analysis and pacemaker detection Protection against interference from defibrillation and electrosurgical unit Adjustable 3 level audio and visual alarm Applicable to icu, ccu, operation, adult, pediatrics and neonatal patient Built-in high-capacity battery, battery-low indicator Optional with thermal recorder, ibp
Standard parameter: ECG, RESP, NIBP, SpO2, TEMP, PR. 12.1" large-screen color TFT display 7-lead ECG waveforms display ,big font observational interface Reviewable ECG waveforms, Maximum 72 hours reviewing graphic trends Digital SpO2 technique, precise measurement for weak perfusion and finger shaking Arrhythmia and S-T segment analysis and pacemaker detection Protection against interference from defibrillation and electrosurgical Unit Adjustable 3 level audio and visual alarm Applicable to ICU, CCU, operation, adult, pediatrics and neonatal patient Built-in high-capacity battery, Battery-low indicator Optional with thermal recorder, IBP and ETCO2
Supplier: Radiant heat warmer, phototherapy unit , pulse oximeter, multipara monitor, ECG machine
Buyer: Radiant heat warmer, phototherapy unit , pulse oximeter, multipara monitor, ECG machine
Supplier: Multipara monitor, multi parameter patient monitor, patient monitor, syringe pump, infusion pump, ECG machine
Buyer: Multipara monitor, multi parameter patient monitor, patient monitor, syringe pump, infusion pump, ECG machine