Sulfur Recovery Unit (SRU): SRU is widely used to recover sulfur-containing, poisonous acidic gas in oil refinery engineering process. The most commonly used process in claus sulfur recovery practice is Claus Process, which is to burn the incoming gas with oxygen, refrigerate the burnt gas and recover sulfur from the burnt gas. SRU converts sulfur gas such as H2S into elemental sulfur, so as to convert waste into treasure and protect the environment.
Application of SRU:
1. Separate sulfur from sulfur-containing oil
2. Recover the wasted material efficiently
3. This unit can reach rather high sulfur purity
Advantages of SRU:
1. SRU reduces the pollution of refineries greatly, and it's environmental friendly.
2. SRU turns H2S into useful material, reduce power consumption, can being huge economic benefits.
3. Harmless processing of H2S which was produced during the refining process.
Now the price of claus unit is reasonable, if you have needs, please contact us.
Function of Solvent Reclaiming Unit : Calstar Solvent Reclaiming Unit is the machine that works through the method of instillation to reclaim the used solvent into reusable condition. Choosing our Solvent Reclaiming Unit will save you lots finish products cost of using expensive solvent, protect the whole green environment and keep everybody healthy. Solvents that could be reclaimed: Isopropyl alcohol, acetone and butanone, days that water, get water to wash, washing Net water, wash mode water, diluents, Banana oil, alcohol, benzene, washing solvent, acetic acid esters, halogenated hydrocarbons, trichloro oxide, trichlorethylene, petroleum solvents. Treatment Flow Chart : Auto parts ,Electronic products, Colored drawing on pottery gold ornament, Precision casting, Hardware manufacture, Movement equipment, Artificial leather, Revertex product ,Coating chemical industry , LED product ,FRP product, Tree ester shoes material , LCD optics product. Operation principle :separation through evaporation. Features This set of A-model is very fast , safe and simple to operate . They work well with most organic sovants popular in today's industry . Recovered materials are like now and can be recycled back into while saving the environment. Type:A10 Volume(L):10 Operating Temperature(íµ):50~210 Recovery(¬ç):95 Socket Source(ACV):220 Power(kw):2.0 Dimensions(mm):520*490*1105 Time per cycle(Hr):1.0 Weight(kg):44.
LZZG Ultra Sand Recovery Units use hydrocyclone recover fine sand that overflowing from the sand washing plants, generally, 0.04-3mm fine materials can be well recycled >95%, without additional chemicals. LZZG Ultra Sand Recovery Units are designed 30-350tph and produced final product with residual water content 10â??15%. This recycling units are suitable for aggregates, coal ,concrete, frac sand, idustrial sands, frac sand, and more. Working principle The overflow of washing machines(wheel washers or washer screws)is fed to hydrocyclones by slurry pump with high pressure. Most fine materials (+300 mesh) concentrated by hydrocyclones goes to dewatering screen through underflow exit. After dewatering, the hydrocyclone underflow turn to be a dryer materials, moisture content
A60Ex, organic solvent recovery machine, is complied with Chinese explosion-proof standard (CNEX: Ex d IIB T2 Gb, certificate No. CNEx16.2110X) and European standard (ATEX). The design of Tilting-type and air-cooled system are for better operation of solvent recovery. After distilling and cooling for proximate 3 hours, waste solvent will be purified and ready to reuse. A60Ex is suitable for medium amount of organic solvent recycling. Recoverable solvents list 1. Aromatics categories: toluene, xylene, mesitylene, etc. 2. Aliphatic hydrocarbons: pentane, hexane, octane, etc. 3. Alicyclic hydrocarbons : cyclohexane, cyclohexanone, toluene and cyclohexanone, etc. 4. Halogenated hydrocarbons: chlorobenzene, dichlorobenzene, methylene chloride, trichlorethylene, etc. 5. Alcohols: methanol, ethanol, isopropyl alcohol, etc. 6. Ether: ether, propylene oxide, etc. 7. Esters: methyl acetate, ethyl acetate, butyl acetate, etc. 8. Ketone: acetone, methyl ethyl ketone, methyl isobutyl ketone, etc. 9. As well as other organic solvents that are not listed. Unrecoverable solvents list 1. Nitrocellulose (nitro), and oxidant solvents and other hazardous materials. 2. Strong acid or strong alkaline solvents. 3. Highly toxic solvents. 4. Pairs of stainless steel or brass with a strong corrosive solvent. Main Features Explosion-proof design: in compliance with Chinese Explosion-proof standards (CNEX) and European standards (ATEX), Standardized production, stable and durable quality guaranteed. Tilting-type: gradually tilting and pouring out waste residue which is easily removed. SUS304 stainless steel tank is used to prevent chemical corrosion. Two layers design, reinforcement barrelhead design, precise temperature control, explosion-proof, anti-leakage are made for safer operation. Heating Method: heat medium (heat transfer oils) indirect heating; Digital heating temperature controller: advanced numerical display, accurate and convenient heating temperature control; Multiple operational safety protection functions: power off or power on by timing or temperature pre-set, excessive temperature protection features; high-voltage protection function; power failure protection function. Short reclaiming process, simple operation. Less maintenance.
Application On-site maintenance for hvacr system Commercial a/c central a/c Small household a/c Refrigerator production factories Automative industry Unique advantages • long time running sustainingly up to 24 hours • oil free compressor – maintenance free • capable of handling all kinds of refrigerants • automatic high pressure cut-off switch for safety • the outer shell adopts one-off rotary technology with high intensity and concussion resistance. • overall protection device, safe credibility • meet ari700 standards • automatic low pressure shut-off • 2 years warranty • weighs only 17.5kg Features • portability and mobility-ergonomic well balanced design with wheels and handle for all-terrain; • "super cool" fan and efficient condenser design provides fast speed in recovery, recharge and can handle high ambient temperatures; • multi-function valve design and multi-refrigerant capable with self-clearing feature, which prevents cross-contamination; • large filter outlay design, which is convenient for replacing; • optional float cable provides automatic shut off when tanks are 80% full; • cm exceptional compressor, condensing & cooling systems allow fast recovery in high temperature environments; • r410a ready with 550 psi high pressure shut-off switch; • 0 to 55 bar (800-psig) discharge gauge to handle r-410a; • " self-clearing" valve.No need to turn off the unit when switching from the recovery to self-clearing; • pressure gauge measured in psi & bar; • on board suction and discharge gauges. 480mm(l)×220mm(w)×370mm(h) 17 kg
Application On-site maintenance for HVACR system Commercial A/C Central A/C Small household A/C Refrigerator Production Factories Automative industry Unique Advantages • Long time running sustainingly up to 24 hours • Oil free compressor – Maintenance free • Capable of handling all kinds of refrigerants • Automatic high pressure cut-off switch for Safety • The outer shell adopts one-off rotary technology with high intensity and concussion resistance. • Overall protection device, safe credibility • Meet ARI700 Standards • Automatic Low Pressure Shut-off • 2 years warranty • Weighs only 16.8KG Features • Portability and mobility-ergonomic well balanced design with wheels and handle for all-terrain; • "Super cool" fan and efficient condenser design provides fast speed in recovery,recharge and can handle high ambient temperatures; • Multi-function valve design and multi-refrigerant capable with self-clearing feature,which prevents cross-contamination; • Large filter outlay design,which is convenient for replacing; • Optional float cable provides automatic shut off when tanks are 80% full; • CM exceptional compressor,condensing & cooling systems allow fast recovery in high temperature environments; • R410A ready with 550 psi high pressure shut-off switch; • 0 to 55 bar (800-psig) discharge gauge to handle R-410A; • " Self-clearing" valve.No need to turn off the unit when switching from the recovery to self-clearing; • Pressure gauge measured in PSI & BAR; • On board SUCTION and DISCHARGE gauges. 480mm(L)×220mm(W)×370mm(H) 17 kg
Portable residential A/C oil less refrigerant recovery equipment recharge system CM2000 price Products in CM2000/2000A/3000A series refrigerant recovery machine are special for out maintenance. Stability of these small refrigerant recovery machine are with todays?s world advanced level. Applications are as follows: small household A/C,automotive A/C, refrigerator production factories, on-site maintenance of small and medium HVAC/R equipments(portable refrigerant recovery machine ) Unique Advantages of CM2000 series refrigerant recovery machine - Long time running sustainably up to 24 hours - Oil free compressor - Maintenance free - Capable of handling all kinds of refrigerants - Automatic high pressure cut-off switch for Safety - The outer shell adopts one-off rotary technology with high intensity and concussion resistance. - Overall protection device, safe credibility - Meet ARI700 Standards - Automatic Low Pressure Shut-off - 2 years warranty - Weighs only 16.8KG
WFL36 Refrigerant Recovery Unit Performance has become a forefront of the industry and meet ARI-700 standards; Universal for CFC/HCFC/HFC of medium & low pressure refrigerants; 24-hour continuous working; No need for special maintenance when recovery different refrigerants, just evacuation. No cross contamination; High performance/price ratio - rapid investment return Maintenance is simple. WFL36 Refrigerant Recovery Unit Transfer refrigerants; Service chillers & other large & medium cooling systems below 10000 cooling ton; Large & medium central A/C factories; On site maintenance of lage & medium HVAC/R products
Advantages Performance has become a forefront of HVACR industry Meet ARI-700 standards Universal for CFC/HCFC/HFC of high&low pressure refrigerants 24-hour continuous working No need for special maintenance when recovery different refrigerants, just use self-purging function. No cross contamination Application Transfer refrigerants on your job-site; Service chillers & other medium cooling systems; Small & medium central A/C factories; On site maintenance of small & medium HVAC/R products Features Oil-free lubricating compressor ¡§C compatible with CFC/HCFC/HFC refrigerants; Self-purging design ¡§C prevent cross contamination; Multi-function valve design- simple operation; Perfect protection system ¡§C safe credibility; Thorough recovery refrigerant and automatic stop when the suction pressure is up to -0.04Mpa Light weight ¡§C air cooled type only 160lbs, water cooled is much lighter 0-1
Features This set of A-model is very fast , safe and simple to operate . They work well with most organic solvents popular in today's industry . Recovered materials are like now and can be recycled back into while saving the environment. Function of Solvent Reclaiming Unit : Calstar Solvent Reclaiming Unit is the machine that works through the method of instillation to reclaim the used solvent into reusable condition. Choosing our Solvent Reclaiming Unit will save you lots finish products cost of using expensive solvent, protect the whole green environment and keep everybody healthy. Solvents that could be reclaimed: Isopropyl alcohol, acetone and butanone, days that water, get water to wash, washing Net water, wash mode water, diluent, Banana oil, alcohol, benzene, washing solvent, acetic acid esters, halogenated hydrocarbons, trichloro oxide, trichlorethylene, petroleum solvents. Treatment Flow Chart : Auto parts ,Electronic products, Colored drawing on pottery gold ornament, Precision casting, Hardware manufacture, Movement equipment, Artificial leather, Revertex product ,Coating chemical industry , LED product ,FRP product, Tree ester shoes material , LCD optics product. Equipment characteristics 1. Electric Control Box: Enclose anti-explosion component to prevent fire accident from solvent reaction . 2. General Control Box : A. Double Temperature Control: 3stages setting to prevent solvent and increase recycling output. B. Auto shut-off time to preset minimum volume of solvent and prevent gas explosion . C. Over heat protection system will be active when the machine temperature is too high. Tank : imported Ss304 heave duty stainless steel material. Condense pipe : anti-explosion electric system with blowing fan. Heating system: enclose heating connectors with anti-explosion design. Switch: anti-explosion design, auto return to original position. Heat conduction system: anti-explosion electric system controls heat transfer oil circulation .Extend oil life and keeping recycling process wording. Type:A30Ex Volume(L):32 Operating Temperature(íµ):50~210 Recovery(¬ç):95 Socket Source(ACV):220 Power(kw):2.0 Dimensions(mm):825*638*1280 Time per cycle(Hr):2.0 Weight(kg):116.