DESCRIPTIOn: Titanx100 RADIOGRAPHY RATING: 25-100mA, stations 45kVp to 100 kVp in 15 steps OUTPUT: 8KW RECTIFICATION: Full Wave Rectified TIMER: 0.06 to 5 sec DIGITAL DISPLAY : Digital Display of mAs, kV & mA X-RAY TUBE: XD-3/Imported POWER SUPPLY: 230 Voltage AC, 15 Amps LINE REGULATION: 10% 0.6max PROTECTION: Electronic overload Protection TUBE STAND counter Balance Mobile
DESCRIPTION: Titanx RADIOGRAPHY RATING: 25-100mA, stations 45kVp to 100 kVp in 15 steps OUTPUT : 8KW RECTIFICATION: Full Wave Rectified TIMER: 0.06 to 5 sec DIGITAL DISPLAY: Digital Display of mAs, kV & mA X-RAY TUBE: XD-3/Imported POWER SUPPLY: 230 Voltage AC, 15 Amps LINE REGULATION: 10% 0.6max PROTECTION: Electronic overload Protection TUBE STAND: Floor to Ceiling Column Stand
DESCRIPTION: Titanx100 RADIOGRAPHY RATING: 25-100mA, stations 45kVp to 100 kVp in 15 steps OUTPUT : 8KW RECTIFICATION: Full Wave Rectified TIMER: 0.06 to 5 sec DIGITAL DISPLAY: Digital Display of mAs, kV & mA X-RAY TUBE: XD-3/Imported POWER SUPPLY: 230 Voltage AC, 15 Amps LINE REGULATION: 10% 0.6max PROTECTION: Electronic overload Protection TUBE STAND: Counter Balance Mobile
DESCRIPTION- TITANX 100 RADIOGRAPHY RATING- 25-100mA, stations 45kVp to 100 kVp in 15 steps OUTPUT 8KW RECTIFICATION- Full Wave Rectified TIMER- 0.06 to 5 sec DIGITAL DISPLAY- Digital Display of mAs, kV & mA X-RAY TUBE- XD-3/Imported POWER SUPPLY- 230 Voltage AC, 15 Amps LINE REGULATION- 10% 0.6max PROTECTION- Electronic overload Protection TUBE STAND- Spring Balance
Supplier: X ray machines, Mammography machines, digital Xray, OPG machines, C Arm, dental Xray, Portable X ray
Services: Manufacturing and export
Buyer: X ray tubes
PLD7200A U-arm x ray with Toshiba FPD Usages of Surgery X-ray Unit PLD7200A This digital radiographic machine is available for medical teaching, research, medical units for X-ray spot film gastrointestinal photography, remote compartment, and other traumatic perspective X-ray photography and other routine check.The digital x ray machine/x ray machine for sales can be apply to the esophagus, chest, stomach, abdomen, limbs for fluoroscopy and spot film photography. Features of Stationray Digital X Ray System PLD7200A 1.One-step workstation from registration to documentation can easily follow the clinical workflow. 2.DICOM 3.0 interface permits to connect PACS network & dry film printer in hospital. 3.Compact,floor-mounted,U-arm design,fits into smaller rooms without the need of ceiling support structures,and can be installed fast.
1. When adding up voltage, total current is less than 2a and total power is 500w; 2. The current and voltage of x-ray tubes are fixed in three groups, they are: X exposure voltag (kvp) 60 65 70 X-ray current (ma) 0.5 0.85 1.10 3. When adding up voltage, total current is less than 2a and total power is 500w 4. Drain current and earth resistance are in accordant with the stipulates in gb9706.1 5. The three groups of voltage (60kv, 65kv, 70kv) are adjustable. 6. Wireless remote control in any angles within 10 meters part form the control box 7. The parameter of x-ray generator (bulb tube head) the parameter of x-ray tubes A focus index: 0.3*0.3mm2 B. The voltage of the-highest-voltage generator: 90kv C. The highest inverse peak voltage: 90kv D. Filament characteristic: vf=5v+0.5v, f=3a E. Target surface obliquity: 12 F. The cooling manner of bulb tube head: oil immersion The parameter of x-ray generator (bulb tube head): A. Focus-skin distance: 200mm B.The thickness of filter-ray film: more than 1.5mmal C.The leakage rate of x-ray: no more than 0.002mgy/h (no. 29.204.3 in gb9706.12 prescript that the leakage rate of x-ray is no more than 0.25mgy/h) D. The manner of limiting beam: using planigraphic device
Detecting such as stone ,sand,teflon,fe,sus ,non-fe,harder material and so on in the food stuff