Dolph has developed a comprehensive line of waveguide ortho-mode transducer covering C, X, Ku and Ka bands. The devices offer very high performance at a very competitive price. Orthomode Transducers separate a signal applied to the circular waveguide input port into its two linear orthogonal components at the rectangular waveguide output ports between the polarizations. In reverse, two orthogonal linearly polarized signals combine, producing an output in the circular waveguide port. The resulting polarization may be linear, circular, or elliptical depending on the relative phase and amplitude of the two orthogonal input signals. Please call us with your specification and discuss your needs with one of our sales engineers.
Note: Take Ka-Band Waveguide Ortho-Mode Transducer (OMT) as an example.
FAQs of OMT (Orthogonal Mode Transducer)
Definition of OMT (Orthogonal Mode Transducer)
An Orthogonal Mode Transducer (OMT) is a waveguide component commonly referred to as a polarization duplexer. Orthogonal mode transducers are used to combine or split two orthogonally polarized microwave signal paths. One of the paths forms the uplink and travels through the same waveguide as the receive signal path or downlink path.
Application of OMT (Orthogonal Mode Transducer)
Orthogonal mode transducers are used to combine or separate two orthogonally polarized microwave signal paths. One of the paths forms the uplink and travels through the same waveguide as the receive signal path or downlink path. Such equipment may be part of a Very Small Aperture Terminal (VSAT) antenna feed or a terrestrial microwave radio feed; for example, OMTs are often used with feed horns to isolate orthogonal polarizations of signals and transmit transmit and receive signals to different ports.
There are many microwave waveguide manufacturers, but we are one of the best choices for you.
Applications An Electromyography (EMG) use EMG electrodes to pick up the electromyographic signal directly from the skin surface or within the subjects muscle using disposable fine-wire electrodes. Both are typically expressed in SI units micro Volt (mv). The Bioforcen-TB0810 model Biomechanics EMG can be used for biomechanics, engineering, medical research, orthopedics, rehabilitation evaluation, prosthetics, and general industrial uses. Specific uses include gait analysis, testing or stability analysis, neurological analysis, prosthetics fitting, athletic performance, shoe design, and force, power, and work studies. Description The EMG signal from each muscle is individually pre-amplified, band-pass filtered prior to digitization, and then converted to a binary sample for each of the channels. These operations are all performed directly in the subject back-pack to maximize signal quality. The binary information is then sent from the subject back-pack unit, via a single lightweight cable or wireless, to the desktop unit where it checked for transmission accuracy and then converted to an analog signal suitable for almost any analog data recording system. The desktop unit provides full electrical safety isolation for the subject. AMPLIFICATION The Bioforcen-TB0810 model Biomechanics EMG provides excitation and amplification for multiple channels in one convenient package. These amplifiers process the transducer signals and provide outputs suitable for an A/D converter so that the data can be stored and processed by a computer. CALIBRATION Each platform is inspected and tested in JUNE calibration facility. The calibration procedure provides a detailed sensitivity matrix and a complete test of all system components, including the amplifier and the connecting cable if ordered together. SOFTWARE Automated data collection and reduction requires a computer and software. Bioforcen-Analysis, Bioforcen-software package, is specifically designed for biomechanics . EMG channels: 8 High pass filter (1st order): 10 Hz Low pass filter (2nd order): 1000Hz (Butterworth) EMG signal input mode: Raw Signal (¡À3 mV) EMG signal output mode: Signal (0~2 V) EMG channel sample rate 500~4,000 samples per second per channel. Number of event switches: 8 switches, Independent of EMG channels Indicator Lights: USB ok, Status ok Safe Temperature Range: 0í½50OC Compensated humidity Range: 20í½70%RH Safe Excitation Voltage: 9 V DC 180*80*20mm Net Weight: 260g Packaged in aluminum alloy chest
Pwm charging Direct, boost and float auto-charging modes. Optimized control for intelligent adjustment of control parameters based on actual charging / discharging rates. Led indication of system working status. Temperature compensation, high precision digital temperature transducer. Over-load and short circuit protections. Rated charging current: 20a, 30a, 40a System voltage: 12v, 12/24v, 48a As the same above
The controller is equipped with 2 independent counters with inputs that can be configured for 5 V or 24 V voltage level. The required voltage level is determined by the user program with the Counter[0x].5/24V Mode system parameter. Input A is the counter input, B is the count direction input and input Z (zero track) is used to reset. Alternatively, all inputs are 3-bit Gray code inputs (in decoder operation) The following modes of operation can be implemented: Counter function 1 (depending on the count direction input signal) Counter function 2 (not depending on the count direction input signal) Decoder operation with attached absolute rotary transducer
Specification: Technical code for testing of building foundation piles JGJ 106-2003 Technical specification of Dynamic pile tests for Highway Engineering JTG/TF81-01-2004 Technical specification for inspection of concrete defects by ultrasonic method CECS21:2000 Technical specification for detecting strength of concrete by ultrasonic-rebound combine method CECS 02:2005 Code for investigation of geotechnical GB50021-2001 Purpose Testing of building foundation piles by cross-hole sonic logging; Inspection of concrete defects by ultrasonic method, such as uncompacted, cellular, hole area. Detecting strength of concrete by ultrasonic-rebound combine method Detecting strength of concrete crevice by ultrasonic-rebound combine method Detecting defects of one hole by one trigger two receives Testing dynamic performance of geotechnical investigation, rock, concrete etc Performance High efficiency testing. Lifting speed is more than 60m/s(point distance:20cm) Display the test data graphically. User can watch analyzed result directly Fast and precise automatic judge the sound parameters. Real-time wave display assures test efficiency Humanized software design. Software design applies to user and construction plant. Its help information ensure user handle easily Link the rebound apparatus directly. Detect strength of concrete by ultrasonic-rebound combine method with linking rebound apparatus directly, and get strength of concrete in time. The function has applied for national patent Being sensitive to receive signal. Can receive signal more than 10m in concrete without defects Can supply smooth power to radial energy transducer without external power Standard USB storage with big capacity Interior lithium battery supplies power for apparatus working more than 6 hours Portable, small, light apparatus (1.75kg) Extending function: testing thickness of concrete by impacting echo method. Professional and powerful Windows system analysis software. It can export the data to Excel or Word for advanced analysis Technical data Item Specification Main control unit High-performance embedded computer Input method keyboard Interface USB Receive channel Two Transmission mode Continuous and external Receive sensitivity =30uv Amplifier bandwidth 10kHz to 300kHz Sound time accuracy 0.05us Display 640*480 high brightness TFT panel Storage 1G(Interior) 2G(U-Disk) Max sample data length 64k Trigger voltage 65,125,250,500,10
Sck-11 dual axis inclinometer module description The dual axis inclinometer module sck-11 was designed to stationary measurements of inclinations of two orthogonal axes in relation to earth. Recommended range of measured angles maintains from -70 to +70 deg. Due storing of new scaling values to internal registers it is possible to change measurement unit and resolution to any other linear. Build in offset registers allows user to measure relative angles and self zeroing after mounting. In addition to two registers containing information about sck-11 installation plane angle relative to the earth (two angles with the offset function), threre are available additional two records containing information on the accelerations in the same axes, what makes measurement of transducer movement more precision. Sck-11 dual axis inclinometer module features - power supply, : 10 - 36v dc, - measurement range, : +/-70 deg. In relation to earth, - protection level, : ip 67, - weigh, t: 350 g, - two measurement channels - build-in temperature sensor - resistance for mechanical damages - aluminium housing Sck-11 dual axis inclinometer module applications Possible application fields: - industry and farming - position control equipement - measurement systems of lifts etc.
Humidity & Temperature sensor - HTU21D 1.Product Description: HTU21D, the new digital humidity sensor with temperature output of MEAS is about to set new standards in terms of size and intelligence: Embedded in a reflow solderable Dual Flat No leads (DFN) package of 3 x 3 mm foot print and 0.9 mm height it provides calibrated, linearized signals in digital, I²C format. HTU21D digital humidity sensors are dedicated humidity and temperature plug and play transducers for OEM applications where reliable and accurate measurements are needed. Direct interface with a micro-controller is made possible with the module humidity and temperature digital outputs. HTU21D digital humidity sensors are low power consumption designed for high volume and cost sensitive applications with tight space constraints. Every sensor is individually calibrated and tested. Lot identification is printed on the sensor and an electronic identification code is stored on the chip – which can be read out by command. Furthermore, the resolution of HTU21D digital humidity sensor can be changed by command (8/12bit up to 12/14bit for RH/T), low battery can be detected and a checksum improves communication reliability. With made improvements and the miniaturization of the sensor the performance-to-price ratio has been improved – and eventually, any device should benefit from the cutting edge energy saving operation mode. 2.Main Application: • Automotive • Home Appliance • Medical • Printers • Humidifier • Multimedia: Smartphone, Tablet 3.Main Features: • Full interchangeability with no calibration required in standard conditions • Instantaneous desaturation after long periods in saturation phase • Compatible with automatized assembly processes, including Pb free and reflow processes • Individual marking for compliance to stringent traceability requirements. 4. PERFORMANCE SPECS : 5. ELECTRICAL AND GENERAL ITEMS : 6. SENSOR PERFORMANCE : 7. RELATIVE HUMIDITY ERROR BUDGET CONDITIONS AT 25° C :