Nitrogen accumulator NXQ-A-10/31.5-L-EH for Kakatiya power
YOYIK relies on a senior technical team, including senior engineers who have participated in major hydropower projects such as Gezhouba and Three Gorges, to provide accurate equipment upgrades and technical transformation solutions. The company strictly follows national standards and is equipped with precision machining equipment to ensure high-quality output in every link, meet the special needs of various power stations and steel companies, and set an industry benchmark.
To meet the needs of the power plant, we have many components available, as follows:
#DF-Nitrogen accumulator NXQ-A-10/31.5-L-EH-DF
valves hydraulic SM4-40(40)151-80/40-10-H919H
piston pump hydraulic system PVH098R01AJ30A250000001001AB010A
seal ring NZK300-16.7/537/537
axial piston type hydraulic pump PVH074R01AB10A250000002001AE010A
10mm stop valve KHWJ40F-1.6P
Gate valve Z41H-40 DN300
Machine seal oil station air bag BNXQA-20/10-L-Y
Ball Valve PD280/A
mechanical seal HSNH280-54NZ
straight stop shut off valve DV12-1-10B/2
SOLENOID VALVE FOR EMERGENCY TRIP SYSTEM CCP230M
solenoid valve SV25-211D AC220V
vacuum pump rear bearing M-206
Stop check valve JC100-16P
Coupling nut DG600-240-03-03
Valve spring seat ring P-1989
rotary servo valve GU/3832-01
Moog valve D633-303B
solenoid valve HQ16.11Z
Electro-hydraulic servo valve G403-517A
O-RING KIT FOR TURBINE HB4-56J8-56
EH regeneration pump 2PE6.5DG28P1-V-VS40
EH oil Re-Circulating pump BB-B80
accumulator bladder kit NXQ A B80/10
RUBBER BLADDER NXQ-A-1.6L/31.5-L-Y
Fire pressure stabilizing pump XBD11/3.47-50GDL
Pump casing wearring PCS1002002380010-01/502.02
hydraulic pump seal replacement TCM589332
AC sealing seal oil pump mechanical seal DLZB820R67
Pneumatically operated angle seat globe valve GEMU 514 PN25 DN25 Material 1.4408
Oil unloading pump 2CY60/1.0
CONTROL OIL RELIEF VALVE RV5-10-0-35
pressure hose SMS-20-1219mm-B
AST crisis interruption module 0508.2624T0301.AW
Guide pin 0069/0070
Solenoid valve 4WE10Y-L3Y/CG24NZ5L
Nitrogen accumulator NXQ-A-10/31.5-L-EH
Nitrogen accumulator NXQ-A-10/31.5-L-EH
MY-DFYL-2024-7-2
Model : uv light Power : 2w Power supply : usb 5v Size: 357*40*35mm Wave length : 275+395nm Lamp beads : uv3535 6v 2w Life span: 8000h Color: black /white Li-battery : 1800ma Sterilization time : cm height 10-20 seconds
AC to DC converter battery charger 150-1000VDC rectifier 120KW power supply Product Introductionï¼? SANDI AC/DC Charger is specially developed for DC chargers. It has high efficiency, high power factor, high power density, high reliability advantage. AC input 3 phase, DC output voltage range from 150 to 1000VDC can be set, compliant with CE safety requirements, EMC standard EN61000-6-3 and EN61000-6-1 Class A, it is an advanced international level charger. Unique function High efficiency over the full load range, full load efficiency greater than 95% Wide output voltage range, 150-1000VDC, suitable for a wide range of Lithium or lead acid battery 5-inch LCD touch screen, easy to operate Flexible application, charging voltage, charging current, charging time, timing charging can be set by LCD screen, easy to operate Main featuresï¼? Powerful protection, overheating, short circuit, overload, overvoltage, undervoltage, etc. Wide input voltage range: 260~ 530Vac, adaptable to various power grid environments Three-phase AC input without neutral wire: Simplifies system design, eliminates the risk of excessive neutral current, and reduces system costs. Dual DSP design, achieve the full digital control, less components means high reliability Wide input voltage range, allows operation in most poor grid conditions Battery anti backflow: effectively protects the battery while ensuring reliable and safe operation of the system Input, output have protective circuit breaker switch Module adopts hot pluggable design, which is convenient for maintenance. RS485 interface (Optional)
SANDI SERIES charging module is for electric vehicle charging station. With single-phase non neutral conductor AC input, it has the advantages of high efficiency, high power density and low harmonic. Functional details 1. Hot plug Plug technology is applied to the charging module to provide convenience for installation and maintenance. The access of the charging module to the system shall not disturb the output voltage of the system. 2. Advanced current sharing technology Under constant voltage working mode, the charging modules can share current automatically within 10S, with degree of unbalance less than �±0.5A. 3. Control of input limited power Refer to Fig. 1-10 for the relation between the output power and input voltage of the charging module. When the input voltage is within 360 Vac ~ 450 Vac (return difference is less than 5V), the module can output the maximum power of 20 KW; when the input voltage is within 260 Vac ~ 320 Vac, the module can still work normally under limited power mode. 4. Control of output constant power When there is a rated input voltage, the output power of the module is 20 KW. Refer to Fig. 11 for the relation between the output voltage and the output current of the module. The SD75050 module uses two operating modes with output voltage ranges of 50 to 750V. The module only selects the operating mode based on the value of the received demand voltage, and does not select the operating mode based on the actual output voltage. 5. Temperature limited power 6. Regulation of output current limiting point 8. Regulation of output voltage The output voltage of the module can be regulated constantly through the external monitoring module, with regulation range of 50Vdc ~ 750Vdc and minimum regulation step of 0.1 Vdc. 9. Fan control The built-in processor of the module can regulate the speed of the fan according to the internal temperature and output current of the module. 10. Protection of input overvoltage/ voltage shortage 11. Output overvoltage protection The overvoltage protection point is 260Vdc ~770Vdc (�±10 Vdc). Default is 778Vdc.The module can be started after manual intervention upon overvoltage protection. 12. Over-temperature protection The environmental over-temperature protection point is 80�°C. When the DC panel has a temperature over 100�°C, the module will stop working; when the DC panel has a temperature below 90�°C, the module will automatically work again. 13. Protection of internal bus fault When the internal bus voltage of the module is beyond the overvoltage/ voltage shortage protection point, the module will be powered off automatically. At this time, there is no output from the module and the fault indicator light is on. 14. Short circuit protection In case of short circuit of the module, it will be subjected to protective shutdown and the red indicator light of the panel is on, and this condition will be transmitted to the monitor of the "module fault".
Bangladesh power system BLADDER FOR ACCUMULATOR NXQ-A-10/20-L-EH is a research and development, production, sales, import agents in one of the manufacturing and processing enterprises. Our company was established in 2004. For more than 20 years, our company's products are widely used in electric power, petroleum, chemical, environmental protection, refractory materials, metallurgy, fire fighting equipment, natural gas, electronics, nuclear industry and other fields. Our company is willing to work with colleagues from all walks of life at home and abroad wholeheartedly cooperation to create a better future Deyang power plant, steel spare parts are as follows: provides multiple types of spare parts and equipments for power plant : #DF-BLADDER FOR ACCUMULATOR NXQ-A-10/20-L-EH-DF IPC power supply ACE-716C DC24V radial piston pump hydraulic 5MCY14-1B k type thermocouple 1200 degree TE-109 pump mechanical seal 109-20SIC/SIC Thermocouple Cylindrical sensor WRKK2-221 thermocouple sensor W08Q0019A pipe joint assembly WZK.W.31.D.0622 thermocouple replacement WRNK2 centrifugal pump vertical DFB-80-80-240 mechanical seals 15F4-IC-20 hydraulic electric pump 50AYZ-50 Resistance Thermometers WPNKZ-630 Platinum Thermocouple Wire W08R0024A thermocouple probe W08B0691A Thermocouple Temperature Measurement WRN2-630 LX1=225*76 replace thermocouple WRK2-001 hydraulic pump piston PVH098R01AAD30A250000002001AB010A M6 thread WREX2-001 B? ngun G11, G12 MPS10/5-230/24/48 vacuum pump vane F3-V10-1S6S-1G-20 vacuum oil pump P-2335 magnetic coupling centrifugal pump YCZ65-250B sealing ring HB4-56J8-180 vane pump parts F3-V20-1S8S-1C11 Filter element JX1013 filter element AD3E301-02D03V/-W globe throttle check valve KJC40-4.0P piston pump hydraulic PVH074R01ABZDV Shaft seal ACG 070K7 NVBP vaccum pump P-1759 Drive shaft gland SR-100V thermocouple range WREX-001 CARD MODULE DMSVC001 Screw pump NSNF210-40 k-type thermocouple TE-208 M6 thread TC03A2-KY-2B/S15 Thermocouple Assemblies TE-304 vaccum pump P-1931A thermocouple types WREK2-294 type k thermocouple TE-401 stainless steel globe valve K65FJ-1.6P rotary vane pump F3V10-1S6S-1C20 LVDT DET100A 0-100mm BLADDER FOR ACCUMULATOR NXQ-A-10/20-L-EH DFYL-2022-2-14-ZYR
Application Use for control and connecting cable on data transmission within building management system, speaker audio system and control measurement. Suitable for use in dry and damp environment. Cable Structure & Features Conductor Material : Tinned copper stranded Insulation : Semi-Rigid PVC Drain Wire : Tinned copper stranded Shielding : Aluminium foil laminated screen Outer Sheath ; PVC Sheath Colour : black or gray Technical Data Standard : UL Style 2464 Approvals : UL apporoved Rated Voltage : 300V Testing Voltage : 1500V Flame Retardant : VW-1 Insulation Resistance : Min 20Mx km Min. Bending Radius : 10 x cable diameter Operating Temp. : -30C / +80C