Alarm cable:4*0.22 bc/tc(shield or unshield) 6*0.22 bc/tc(shield or unshield) 8*0.22 bc/tc(shield or unshield)
This cables are just a example of our
Products, we can make any cables based
On your requirements and specifications
Packing:100m*6 for one carton or 500m/1000m in wooden or plastic drums
For small container:5.85*2.35*2.38
Weight:below 14 ton
Alarm cable Single shielded: al/polyester foil, coveragf+100% Double fully shielded: al/polyester foil and tinned copper braid Structure of unshielded: 0.22mm¼ÿ soft alarm cable Section: 2 x 0.22mm¼ÿ Specification: 2 x 7/0.2 Overall diameter (mm): 3
Supplier: Coaxial cable,alarm cable,security cables ,flexible cable,speaker cable,communication cable,control cable,,.etc.
Supplier: Network cable , coaxial cable , alarm cable , telephone cable , HDMI cables , vga cables , av/rca cable , USB cables , adapter cables
Services: Manufacturer
Supplier: Power cords, lan cable, alarm cable, telephone cable, speaker cable, coaxial cable, network accessory, cabinet, hdmi cable, computer cable, and av cable, adapter etc
Buyer: Copper wire
Specification for telephone drop wire I. Function 1.0 to be used as a connecting line between the subscriber protector and the cable networks. Ii. Specifications A. #13#2 awg copper clad steel conductor Conductor diameter :1.02 mm Tolerance diameter :+0.03 mm :-0.06 mm Copper cladding thickness :0.0305 mm Percent conductively :30% Max. Resistance @ 20 c :74.91 ohm/km Min. Tensile strength :106.12 kg/sq. Mm (151, 000 psi) Min. Elongation :1.40% Dielectric withstand voltage :7, 500 v de B. Polyethylene insulation Overall dimension Major diameter :5.50 mm (min.)-8.0 mm(max.) Minor diameter :3.00 mm (min.)-5.0 mm(max.) Insulation thickness :min. 1.0 mm at any point Min. Tensile strength :16.20 mpa (1.651 kg/sq.Mm.) Min. Elongation :750% Min. Insulation resistance :92 m ohms-km Color :black Surface smoothness :smooth Crack resistance : > 500 hrs. According to the customers
Supplier: Cctv, fire detection and alarm systems, biometrics, access control, paging systems. intercom, burglar alarm, structured and data cabling, cable pulling, roughing ins and etc.
Services:
Buyer:
Telecommunication cable Four types of unshielded wires, five types of data telecommunication cables Cables, electric wires, power wires Application: horizontal sub-system part in the premises distribution system Telecommunication cable
Conductive material: wire made of soft annealed electrolytic copper Conductor insulation: hdpe The cable jacket: pvc An aluminum tape shield is helically applied over the cable core with a minimum overlap of 25% or 5 mm (0.19"), thickness 0.025 mm (0.001"), width 20 mm (0.78"), and braid of 16 tinned copper wires
ò Conductor: bare copper wire +0.54 ¦ 0.01 mm (0.021 ¦ 0,0004"), 24 AWG ò Insulation: high-density polyethylene, minimum thickness at any point 0.18 mm (0.007") ò Diameter: 0.99 ¦ 0.02 mm (0.039 ¦ 0,0008") ò Color of twisted pairs: blue white/ blue, orange white/ orange, green white/ green, brown white/ brown ò 4 twisted pairs with polyethylene spacer, material of jacket: PVC ( minimum thickness of jacket at any point 0.4 mm (0.016") ) ò Outer diameter: 6.2 ¦ 0.2 mm (0.24 ¦ 0.008")