ER-MNS-05 Cost-Efficient Triaxial MEMS North Seeker
Technical Features
Triaxial MEMS gyro and accelerometer
Full temperature compensation
High performance and mini size
Light weight, low power consumption
Resistant to harsh mechanical environment
Applications
North seeking in logging tools/gyro tools
Pointing, steering and guiding in advanced mining/drilling equipment
Initial alignment in weapon/UAV launch systems
Direction pointing and tracking in satellite antenna, target tracking system
Guidance and navigation in navigation grade MEMS weapon system
Orientating and positioning in railway train system
Precision platform attitude measuring and controls
Precision attitude, position measuring in navigation grade MEMS IMU/INS
North finding and positioning in land surveying/land mobile mapping system
Petroleum exploration
Bridge, tall building, tower, dam monitoring
Rock and soil monitoring
Mining
SANDI SERIES charging module is for electric vehicle charging station. With single-phase non neutral conductor AC input, it has the advantages of high efficiency, high power density and low harmonic. Functional details 1. Hot plug Plug technology is applied to the charging module to provide convenience for installation and maintenance. The access of the charging module to the system shall not disturb the output voltage of the system. 2. Advanced current sharing technology Under constant voltage working mode, the charging modules can share current automatically within 10S, with degree of unbalance less than �±0.5A. 3. Control of input limited power Refer to Fig. 1-10 for the relation between the output power and input voltage of the charging module. When the input voltage is within 360 Vac ~ 450 Vac (return difference is less than 5V), the module can output the maximum power of 20 KW; when the input voltage is within 260 Vac ~ 320 Vac, the module can still work normally under limited power mode. 4. Control of output constant power When there is a rated input voltage, the output power of the module is 20 KW. Refer to Fig. 11 for the relation between the output voltage and the output current of the module. The SD75050 module uses two operating modes with output voltage ranges of 50 to 750V. The module only selects the operating mode based on the value of the received demand voltage, and does not select the operating mode based on the actual output voltage. 5. Temperature limited power 6. Regulation of output current limiting point 8. Regulation of output voltage The output voltage of the module can be regulated constantly through the external monitoring module, with regulation range of 50Vdc ~ 750Vdc and minimum regulation step of 0.1 Vdc. 9. Fan control The built-in processor of the module can regulate the speed of the fan according to the internal temperature and output current of the module. 10. Protection of input overvoltage/ voltage shortage 11. Output overvoltage protection The overvoltage protection point is 260Vdc ~770Vdc (�±10 Vdc). Default is 778Vdc.The module can be started after manual intervention upon overvoltage protection. 12. Over-temperature protection The environmental over-temperature protection point is 80�°C. When the DC panel has a temperature over 100�°C, the module will stop working; when the DC panel has a temperature below 90�°C, the module will automatically work again. 13. Protection of internal bus fault When the internal bus voltage of the module is beyond the overvoltage/ voltage shortage protection point, the module will be powered off automatically. At this time, there is no output from the module and the fault indicator light is on. 14. Short circuit protection In case of short circuit of the module, it will be subjected to protective shutdown and the red indicator light of the panel is on, and this condition will be transmitted to the monitor of the "module fault".
Supplier: Industrial electrical wires and cables, ups systems and ancillary, junction boxes, mccb, relays and various other electrical products and equipment.
Services: We believe in quality, cost effectiveness and timely service. we try to understand and do the best as per the client requirements.
Buyer: Industrial electrical parts
Supplier: Transformers and other electrical products, clothing, cosmetics, general merchandise
With high efficiency and high power factor, Fuji Electric's Medium-voltage Variable Speed Drives contribute significantly to cost reduction and energy conservation. Fuji's Medium-voltage Variable Speed Drives products are applicable in a wide range of fields from plants to general industry and feature superior ease of maintenance.
Maximum link rate to up to 20 Gbps/lane and features more efficient 128b/132b channel coding, delivering a maximum payload of 77.37 Gbps First standard to support 8K resolution (7680 x 4320) at 60 Hz refresh rate with full-color 4:4:4 resolution. Enhanced EMI and RFI Application: Consumer Application as PC, TV, Monitor, Tablet.
Flexible fireproof cables are composed of copper stranded wires, mineral compound insulation, and mineral compound sheaths. This kind of cable has non-combustible, smoke-free, non-toxic and fire-resistant characteristics. The structure of the flexible mineral insulated cable adopts a flexible structure and materials that are made of mineral compounds, which make up for the defects of hard structure, flammability, and toxicity. It also has some advantages that other cables cannot have, such as: fire resistance, large current carrying capacity, Impact voltage resistance, mechanical damage resistance, halogen-free, non-toxic, explosion-proof, waterproof, corrosion resistance, long life, safety, overload resistance, high temperature resistance, low cost, etc. Flexible fireproof cables have an important role in protecting lives, materials, and information security. They are used in trunk lines, fire lines, escape rescue systems, such as emergency lighting, fire monitoring, alarm systems, elevator systems, smoke exhaust systems, and control lines, etc. Flexible fireproof fireproof cables used in trunk lines, fire lines, escape and rescue systems, such as emergency lighting, fire monitoring, alarm system, elevator system, smoke exhaust system, and control lines, etc. Flexible fireproof fireproof cables used in Public buildings: high-rise buildings, underground buildings, hotels and restaurants, hospitals, schools, business centers, government affairs centers, department stores, large supermarkets, logistics warehouses, financial institutions such as banks, securities and insurance, post and telecommunications centers, power control rooms, substation rooms, museums, memorials and other historic buildings. Flexible fireproof fireproof cables used in Infrastructure: airport terminals, stations, hub centers, ports, subway systems, Bridges, tunnels. Flexible fireproof fireproof cables used in Industry: coal mining, coal chemical industry, oil field mining, petrochemical industry, oil refinery, metallurgical industry, iron and steel industry, shipbuilding industry, aerospace, electric power industry, pharmaceutical industry, glass industry, paper industry, military system. Flexible fireproof fireproof cables used in Fire prevention, explosion prevention, high temperature places: oil depot and gas station, natural gas transmission and compression station, garden landscape, historic sites, wood structure buildings
Technical Features Triaxial MEMS gyro and accelerometer Full temperature compensation High performance and mini size Light weight, low power consumption Resistant to harsh mechanical environment Have software online upgrade function Applications North seeking in logging tools/gyro tools Pointing, steering and guiding in advanced mining/drilling equipment Initial alignment in weapon/UAV launch systems Direction pointing and tracking in satellite antenna, target tracking system Guidance and navigation in navigation grade MEMS weapon system Orientating and positioning in railway train system Precision platform attitude measuring and controls Precision attitude, position measuring in navigation grade MEMS IMU/INS North finding and positioning in land surveying/land mobile mapping system Petroleum exploration Bridge, tall building, tower, dam monitoring Rock and soil monitoring Mining