Please click here to check who's online and chat with them.

Ntai06 Abb-Collet Automation

Supplier From China
Sep-26-23

Type Designation:NTAI06
Brand:ABB

Product ID:NTAI06

Catalog Description:AI Termination Unit 16 CH

Long Description:Use with ASI, NKAS



NEW AND ORIGIN ITEM IN STOCK

WITH ONE YEAR WARRANTY

1. lower your support costs
2, Provide on-going availability of automation replacement parts
Quantity available: 1
Warranty: 12 months.
Lead time: 1-2 working days.
Terms of payment:T/T and Western Union.
Courier partners: DHL, UPS, TNT, FedEx and EMS.
Technical specification, manuals and data sheets

Price and Minimum Quantity

Price: $2000
MOQ: Not Specified

Recent User Reviews

This user has not received any reviews yet!

Verification Status


 
 
Contact Supplier
Renew

More Items Similiar to: Ntai06 Abb-Collet Automation

Sep-26-23
Type Designation:DCP10

Brand:ABB

Product ID:DCP10

Catalog Description:AI Termination Unit 16 CH

Long Description:Use with ASI, NKAS



NEW AND ORIGIN ITEM IN STOCK

WITH ONE YEAR WARRANTY

1. lower your support costs
2, Provide on-going availability of automation replacement parts
Quantity available: 1
Warranty: 12 months.
Lead time: 1-2 working days.
Terms of payment:T/T and Western Union.
Courier partners: DHL, UPS, TNT, FedEx and EMS.
Technical specification, manuals and data sheets
May-20-22
Supplier From Huizhou, Guangdong, China
Ig module is damaged due to poor heat dissipation


The frequency converter makes a sudden sound during operation, and the external connection is burned. It is found that the IGBT module of the frequency converter is damaged after disassembly. Through the test of relevant boards, it is found that the IGBT trigger circuit is damaged, and other plates are normal. When removing the frequency converter board, it was found that there were a lot of oil and dust on the power board and current detection board. Turn on the fan of the heat sink of the frequency converter and see that the heat sink is also covered with oil and sundries, which completely blocks the heat dissipation channel of the frequency converter. It is inferred that the Ig module of the frequency converter is damaged due to poor heat dissipation.


Maintenance process: first, completely disassemble the frequency converter, remove the heat sink of the heat dissipation channel, clean the heat sink with air pressure gas, and clean all the internal structural parts and boards of the frequency converter. Install the IGBT module. When installing the IGBT module, install it in sequence according to the requirements of the module, with appropriate torque. Repair the trigger circuit, and then install other devices in turn. After installation, conduct static test. After the static test results are good, conduct power on test and load test. The on load test is qualified and the maintenance is completed successfully.


Experience summary: Based on the maintenance of several frequency converters in different models and different use environments, it is concluded that the main reason for the damage of frequency converter IGBT module is the poor use environment, which leads to the damage of electronic components on gate drive card and the blockage of heat dissipation channel of frequency converter* The easily damaged devices are voltage stabilizing tube and optocoupler. Check whether there is a problem in the driving circuit. Compare whether the resistance of each trigger terminal is consistent when power is off. The voltage waveform at the trigger end can be measured after power on. However, some frequency converters cannot be started without being installed into the module. At this time, a false load is connected in series at the p-end of the module to prevent the module from being burnt out due to touching the originator or other lines by mistake during inspection.
Mar-10-22
ABB PP874

The most common temperature sensors are: motor sizes IEC180 225: thermal switch (e.g. Klixon) motor sizes IEC200 250 and larger: PTC or Pt100.See the firmware manual for more information on the motor thermal protection, andthe connection and use of the temperature sensors.Protection against short-circuit in the motor cableThe drive protects the motor cable and motor in a short-circuit situation when themotor cable is dimensioned according to the
Mar-10-22
ABB PCO 011

To meet the European Union Directives, according to standard EN 60204-1, Safetyof Machinery, the disconnecting device must be one of the following types:â?¢ switch-disconnector of utilization category AC-23B (EN 60947-3)â?¢ disconnector that has an auxiliary contact that in all cases causes switchingdevices to break the load circuit before the opening of the main contacts of thedisconnector (EN 60947-3) circuit breaker suitable for isolation in accordance with EN 60947-2.
Mar-10-22
AO895 3BSC690087R1


Only one permanent magnet motor can be connected to the inverter output.It is recommended to install a safety switch between the permanent magnet motorand the drive output. The switch is needed to isolate the motor during anymaintenance work on the drive.Planning the electrical installationSupply connectionDisconnecting deviceInstall a hand-operated input disconnecting device between the AC power sourceand the drive. The dis-connecting device must be of a type that can be locked to theopen position for installation and maintenance work.
Oct-25-21
item no.: 57160001-ADF
lead time: 2-3 days
product orgin: Switzerland
brand: ABB
shipping port: Xiamen
payment: T/T and Western Union.
price: $1/9999
market price: $999
price range: 1-50/888$
color: metal colour
ABB DSDP170 57160001-ADF
Please check if anything interested to you and if quote need.


New option PROFINET Fieldbus Adapter is added to section
Replacement of fieldbus adapter in the computer unit DSQC
639.
New option PROFINET master/slave is added to section
Replacements of PCI boards in computer unit DSQC 639.
New option Euromap II upgrade option 671-4 added in section
Installation of add-ons.
Filter time for safety stop AS/GS/SS is added in section The
MOTORS ON/MOTORS OFF circuit on page 68.
Instructions how to replace the brake resistor bleeder in the Dual
Cabinet Controller, Drive Module is added to section
Repacement of brake resistor bleeder.




Pls notice as below when inquiry:
A:ALL quote are basic on EX-WORK
B:Lead time:2-3 days
C:Delivery time: 5-7 days
D:Payment Term:T/T
E:ship to you via DHL/TNT/UPS/EMS/Fedex.
Oct-22-21
item no.:12P2536X062
lead time:2-3 working days
product orgin:USA
brand:Emerson
shipping port:xiamen
payment:T/T and Western Union
price:$121/1200
market price:$900
price range:1-78/908$
color:metal color
Jun-30-21
(For genuine pic,plds kindly email me )General Electric DS200LDCCH1AGA GE PC board DS200LDCCH1A

The RPI shows how quickly modules can be scanned, not how quickly an application can use the data. The RPI is asynchronous to the program scan. Other factors, such as program execution duration, affect I/O throughput


Honeywell: TDC 2000, TDC3000, TPS...

TRICONEX: 3008,3625,3508E.3721,3700A 4351B...

Woodward: 9907-162, 9907-164, 9907-165, 9907-167...

FOXBORO: FBM203,FBM204,FBM217,FMB231...

BACHMAN: CM202,DI232,MPC240,NT255,AIO288...

ICS: T8403,T8431...

HIMA: F3330,F3236 ,F6217,F7126,F8621A....
Dec-24-20
Other products:

Bently Nevada:

3500/3300 Surveillance protection syste, Proximitor eddy current sensor probe

EPRO:

PR6422/PR6423/PR6424/PR6426 eddy-current transducer, PR9268series Electrodynamic absolute vibration sensor MMS6000 system

ENTEK:

Eddy-current transducer probe, Vibration monitoring table double channel axis vibration monitoring table C6652

Rockwell Allen-Bradley:

SLC500: 1747/1746 series

MicroLogix: 1761/1763/1762/1766/1764 series

CompactLogix: 1769/1768 series

Logix5000: 1756/1789/1794/1760/1788 series

PLC-5: 1771/1785 series

Schneider Modicon:

Quantum 140series: CPU processor module, Communication module, Analog input output module, Digital input output module

GE: IC693/IC695/IC697/IC698/IC200/IC660/IC670 CPU module, Communication module, Analog digital module


EX2100, EX2000 Excitation system card, IS200 series DS200 series

Invensys Foxboro:

I/A Series system, FBM(input / output modules) sequential control, Ladder logic control, Accident recall processing, Digital-to-analog conversion, Input / output signal processing, Data communication and processing

Invensys Triconex:

Redundant fault-tolerant control system, the most modern fault-tolerant controller based on triple-module redundancy (TMR) architecture

Westinghouse:

OVATION system, WDPF system, WEStation system

Honeywell:

Alcont, Experion LS, Experion PKS, Experion HS, Plant Scape, TDC 2000, TDC3000, TPS, security system

ABB:

AC800M series module,Industrial robots spare parts DSQCseries, Bailey INFI 90, 800xA, Advant OCS with Master Software, with MOD 300software Advant OCS, Freelance - Distributed Control System for Process Industry,Symphony Melody, Satt OCS, Symphony DCI System Six, Harmony/INFI 90, Security system

Emerson:

DeltaV system Dual - channel redundant security system Redundant controller

Power supply module I/O unit Analog AImodules Analog AO module

Siemens:

Siemens MOORE, 6ES5 series, 6GKseries, 6DDseries, 6AR series

Yokogawa:

CS3000 system CPU control module, Analog module

Woodward:

SPC valve position controller 505/505E(9907-162, 9907-164, 9907-165, 9907-167)digital controller, 2301A controller, 9905 series, 2301D-ST series

Verification Status