Infusion pump Specifications Controls: Drop counting and adjusting the delivery rate automatically Pump type: peristaltic finger Applicable iv sets: Various iv sets(including lucifugal iv sets) Accuracy: 25drop/min:2%, >25drop/min:3% (used in the drop counting control way) 5% (used in the volumetric control way with the correct calibration) Delivery rate range: 1½400drop/min(1drop/min step) 1.0ml/h½1200ml/h (1.0ml/h½99.9ml/h, 0.1ml/h step; >99.9ml/h, 1ml/h step) Delivery time range: 1min½1999min (1 min step) Volume limit range: 0½9999ml (1 ml step) Total volume range: 1½9999ml (1 ml step) Purge rate: 600ml/h Kvo rate: When the delivery rate 10ml/h, kvo is 1ml/h. Otherwise kvo is 3ml/h. Alarms: Air-in-line, infusion complete(a volume limit has been set), empty container, occlusion, door open, over time, no drop sensor, operation error, low battery and other device failures. Power source: Ac power supply: ac 100 to 240v10%ú¼50/60hzú+ Internal li battery: 11.5v, 2000mah. Battery life with continuous operation is approx. 8 hours (when using a new, full charged battery and running at 20drop/min with any standard of iv set). Power consumption: 25va Shock protection: classó, type bf Dimensions: 130mm 200mm 230mm
3.5 inch LCD screen for clear vision within 5 meters Different types of indicator One-button night mode design for patientâ??s more comfortable rest at night User friendly numeric setting key Pull & Push hook design for easier door open and close Anti-slip pump base support Finger-tip peristaltic pump with down-stream free-flow protect
Automatic calibration Audible and visible alarms Three working mode: rate/time/volume With ultrasonic sensor for drop-counting Lcd, night operable English or other language display Specifications Drop detector: outside caliper rotary detector. (patented technology) Control way: Drop counting and adjusting the delivery rate automatically Pump type: peristaltic finger Applicable iv sets: Compatible with iv sets of any standard (including lucifugal iv sets) Accuracy: ín25drop/min: ía2%, >25drop/min: ía3% (with the drop counting control mode) ía5% (with the rate control mode after the correct calibration) Delivery rate range: 1í½400drop/min(1drop/min step) 1.0ml/hí½1200ml/h (1.0ml/hí½99.9ml/h, 0.1ml/h step; >99.9ml/h, 1ml/h step) Delivery time range: 1miní½1999min (1 min step) Volume limit range: 0í½9999ml (1 ml step) Total volume range: 1í½9999ml (1 ml step) Rapid injection: 600ml/h Bolus: bolus rate 10-1200ml/hr, bolus volume: max of 100ml Kvo rate: When the delivery rate ín10ml/h, kvo is 1ml/h. Otherwise kvo is 3ml/h. Alarms: Air-in-line, infusion complete when limited volume has been set, empty container, occlusion, door is open, waiting time over, no drop been detected, operational errors, low battery, other device failures. Power supply: Ac power supply: ac 100 to 240vía10%ú¼50/60hzú+ Internal li battery: 11.1v, 2000mah. 6 hours of continuous operation on a new fully charged battery with the rate of 20 drops/min. Power consumption: ín25va Safety level: classó±, type cf Operating conditions: ambient temperature: 5 to 40íµíírelative humidity: 20 to 90% Storage conditions: ambient temperature: -10 to 55íµíírelative humidity: 10 to 90% Accessories: ac power line, operational manual Dimensions: 130mm(l)íß 200mm(w) íß 230mm(h) Net weight: approximately. 2.0kg
1.3.5 inch LCD screen for clear vision within 5 meters 2.Special designed extension line grip 3.Different types of indicator 4.One-button night mode design for patientâ??s more comfortable rest at night 5.Compatible with different brands of 5,10,20/30,50/60 ml syringes 6.User friendly numeric setting key 7.More stronger syringe fixing slice & clamp 8.Free stacking of single syringe pumps for easy space stations in ICU, NICU, OT etc
4.3ã?? color touch LCD display with text and image ±5% high accuracy to make sure safe infusion 8 infusion modes to satisfy different infusion requirements Double pressure sensor and double air bubble sensor reassure infusion safety Programmable and support change rate during infusion Big history records and drug library storage Open system and close system optional Automatic and manual bolus DERS (Drug error reduction system) DPS (Dynamic pressure system) Waterproof level IP34 Up to 9 hours battery life Inter-lockable and free combination between syringe pump and infusion pump
Technical specifications ParameterSpecification Drop detector:Outside caliper rotary detector (patent) Control way:Drop counting and adjusting the delivery rate automatically Fit iv tubes:Iv set of any standard, (including lucifugal iv sets) Pump type:Peristaltic finger Accuracy:±2% when delivery rate 25drop/min (drop & time mode) ±3% when delivery rate >25drop/min (drop & time mode) ±5% volumetric mode after correct calibration Delivery rate range:1-1999min (1min increments) Volume limit range:0-9999ml (1ml increments) Total volume range:0-9999ml ( ml increments) Purge rate:600.0ml/h Bolus function:Bolus rate: 10-1200ml/h, bolus volume: maximum of 100ml Kvo rate:Kvo is 1ml/h when the delivery rate10ml/h, Otherwise kvo is 3ml/h. Occlusion pressure:Three level setting low, medium or high Alarms:Air bubble, infusion over ( when volume limit set), empty, occlusion, door open, waiting over time, operational errors, low battery, device failures. Power source:Ac power supply: ac 100-240v( +/-10%), 50/60hz; Dc 12v for ambulance use Built-in lithium battery: rechargeable, 11.1v, 2000mah. 6 hours of continuous operation at 20drop/min Power consumption: 25va Protection class:Class i, type cf, ipx4 Dimension/net weight:130mm*200mm*230mm , 2.0kg Product list: Products nameModel 1. Medical enteral feeding pumpJyb-500 2. Medical enteral feeding pump with barcode scannerJyb-500s 3. Medical fluid warmerJfw-500 4. Medical infusion pumpJsb-1200 5. Medical infusion pump with drug libraryJsb-1200y 6. Medical single syringe pumpJzb-1800 7. Medical double channel syringe pumpJzb-1800d 8. Medical stackable syringe pumpJzb-1800c 9. Medical syringe pump with drug libraryJzb-1800y 10. Medical tci syringe pumpJzb-2000tci 11. Medical syringe pump with spo2 & heart rate monitoringJzb-2000h In carton
Injection speed 50(60)ml syringe 0.1ml/h—999.9ml/h (0.1ml/h step) 1000ml/h—1500ml/h (1ml/h step) 30ml syringe 0.1ml/h—900ml/h (0.1ml/h step) 20ml syringe 0.1ml/h—600ml/h (0.1ml/h step) 10mlsyringe 0.1ml/h—300ml/h (0.1ml/h step) Mechanical accuracy Within±2% Bolus rate 50(60)ml syringe: 1200ml/h 30ml syringe: 720ml/h 20ml syringe: 480ml/h 10ml syringe: 240ml/h Total injection 0.1ml—9999.9ml (0.1ml step) Alarms Injection soon finish end of injection occlusion improperly Installation of syringe wrong setting low battery etc Kvo speed 1ml/h Operation environment A) temperature +5—+40degree B)humidity 20—90% C)atmospheric pressure 86.0kpa—106.0kpa Dimension 280mm(l)x 210mm(w)x 130mm(h) Syringe Compatible with any brand Weight 2.2kg Package 1pc for each carton, 3.2kg; 35cm (l) × 28cm (w) × 17cm (h) 2pc carton, 6.6kg; 40cm (l) × 39cm (w) × 32cm (h) 3pc carton, 10kg; 59cm (l) × 39cm (w) × 32cm (h)
1. support all sizes of syringes from 2ml to 60ml 2. flow accuracy 2% 3. keyboard input, easy configure.
Syringe pump Characteristics Can be used with any standard syringe. Can identify the dimensions of syringe automatically. Has a broad range of delivery rate setting. Has a unique color lcd and an internal battery with a high capability . Has a three modes of the infusion: rate mode, time mode and body weight mode. Can be set at any of three levels of alarm volume: high, medium and low. Can be set at any of three levels of maximum pressure: high, medium and low. Kvo functionafter infusion is complete, the pump automatically switches to the smallest flow to prevent creating the thrombus. Dimensions: 280mm160mm130mm Net weight: approx. 3.5kg