FIRE ALARM CABLE
Fire Resistant Type
Stranded Conductor BS6387 EN50200 PH30
KEY APPLICATIONS
Fire detection and fire alarm systems for buildings.
Voice alarm systems and emergency voice communication.
Emergency and escape lighting.
Control circuits for fire safety and fire fighting systems.
TECHNICAL DESCRIPTION
Operating Voltage 300/500V
Test Voltage(50Hz) 2.0kV
Conductor Stranded Bare Copper
Insulation Material Silicone Rubber
Jacket Material LSZH
STANDARDS
BS EN 50200 - PH30 Fire Resistant Test - Flame & Shock - 30 Minutes
BS EN 50200 - PH60 Fire Resistant Test - Flame & Shock - 60 Minutes
BS EN 50200 - PH120 Fire Resistant Test - Flame & Shock - 120 Minutes
BS 6387 Category CWZ Fire Resistant Test
TECHNICAL DATA
Number of cores Nominal cross
section
conductor mm Nominal jacket outer diameter Cable weight Conductor
resistance at
20 C
2 0.8 5.7 47.5 23.8
2 1.0 6.1 52 19.5
2 1.5 7.1 70 13.3
2 2.5 8.3 98.5 7.98
4 0.8 6.7 76.5 23.8
4 1.0 7.2 85.6 19.5
4 1.5 8.1 116 13.3
4 2.5 10.4 185 7.89
Application :- The XLPE (Cross Link Poly Ethylene) Power Cables are used under ground as well as over head transmission of power in power plants, industries, projects and all other electrical installations. Features :- Manufactured from bright annealed 99.97% pure bare copper & aluminum conductors. These cables are insulated with XLPE compound. Taped/Extruded inner sheath. Round steel wire / flat galvanised steel grip armoured. The outer sheaths can be PVC, HR PVC, FRLS or FR depending upon the application and requirement. Technical Advantage of XLPE Insulation :- Higher current rating, higher short circuit rating (approx 1.2 times that of PVC), thermosetting in nature, higher insulation resistance (1000 times more than PVC cables), higher moisture resistance, better resistance to surge currents, low dielectric losses, better resistance to chemicals and corrosion, longer service life. Comparatively higher cable operating temperature 90�°C and short circuit temperature 250�°C. Technical Data :- Working Voltage : Up to 1100 V Temperature Range : -15�°C to +90�°C Power Cable Sizes : 1.50 Sq. mm to 400.00 Sq. mm in 2, 3, 3 Copper Control Cable Sizes : 1.50 Sq. mm, 2.50 Sq. mm up to 24 cores. Color Codes : 2 Core Cables - Red, Black 3 Core Cables - Red, Yellow & Blue 3 Core Cables - Red, Yellow, Blue & Black (for Neutral) 4 Core Cables - Red, Yellow, Blue & Black 5 Core Cables - Red, Yellow, Blue, Black & Grey 6 Core Cables & above - Adjacent cores are blue for reference and yellow for direction in each lay Black outer sheath Specification : IS:7098 (Part-1) Packing : 500 / 1000 meters on drums