Catalog No. : 9SS.333.0R04 To 9SS.333.0L14
Material : Stainless Steel 316L,316LVM,Titanium
Size
Hole Item Code
(RIGHT)
4mm 9SS.333.0R04
6mm 9SS.333.0R06
8mm 9SS.333.0R08
10mm 9SS.333.0R10
12mm 9SS.333.0R12
14mm 9SS.333.0R14
(LEFT)
4mm 9SS.333.0L04
6mm 9SS.333.0L06
8mm 9SS.333.0L08
10mm 9SS.333.0L10
12mm 9SS.333.0L12
14mm 9SS.333.0L14
Technical data: Oxygen flow:0.5-5L/min Oxygen concentration:95.5%-87% Output pressure: 40-70kPa Pressure relief mechanism operational at: 250kPa + 25kPa Operation nose Level
Oxygen Concentrator - 0.5-10L/Min Purityï¼? 96% Compressor Life - 25000hours Sound Level 60dB Screen - LED Segment real-time display Power comsumption - 500VA Net Weight - 23k Gross weight:27kg
Fuel LPG. Fuel Tank Capacity 2.0 L Fuel Consumption : App. 225 g P/H Length : 350 mm Height : 330 mm Width : 150 mm Weight(kg) Empty : 1.5 Kg (Empty)
Catalog No. : 9SS.335.0R04 To 9SS.335.0L14 Material : Stainless Steel 316L,316 LVM,Titanium Size Hole Item Code (RIGHT) 4mm 9SS.335.0R04 6mm 9SS.335.0R06 8mm 9SS.335.0R08 10mm 9SS.335.0R10 12mm 9SS.335.0R12 14mm 9SS.335.0R14 (LEFT) 4mm 9SS.335.0L04 6mm 9SS.335.0L06 8mm 9SS.335.0L08 10mm 9SS.335.0L10 12mm 9SS.335.0L12 14mm 9SS.335.0L14
Supplier: Food product, medical tools , metal scrap , oil
Catalog No. : 9SS.330.0R05 To 9SS.330.0L17 Material : Stainless Steel 316L,316 LVM,Titanium Size Hole Item Code (RIGHT) 5mm 9SS.330.0R05 7mm 9SS.330.0R07 9mm 9SS.330.0R09 11mm 9SS.330.0R11 13mm 9SS.330.0R13 15mm 9SS.330.0R15 17mm 9SS.330.0R17 (LEFT) 5mm 9SS.330.0L05 7mm 9SS.330.0L07 9mm 9SS.330.0L09 11mm 9SS.330.0L11 13mm 9SS.330.0L13 15mm 9SS.330.0L15 17mm 9SS.330.0L17
The Zimmer M/L Taper Hip Prosthesis is a product line from Zimmer Biomet, a company that specializes in orthopedic implants and devices. The M/L Taper Hip Prosthesis is used in hip replacement surgeries and consists of a femoral stem that is implanted into the patient's femur. The "M/L 12/14 Taper" designation likely refers to the taper of the femoral stem, with 12/14 indicating the taper size. The "Standard Offset" specification suggests a standard offset design for the femoral stem. The offset refers to the distance between the center of the femoral head and the center of the femoral stem. Standard offset is a common configuration, but there are also variations such as high offset or low offset stems to accommodate different patient anatomies. Key features and considerations for the Zimmer M/L Taper Hip Prosthesis may include: Material: The femoral stem is typically made of biocompatible materials such as titanium or cobalt-chromium alloy. Taper Design: The taper design facilitates the connection between the femoral stem and the femoral head component. Modularity: Some hip prostheses, including those with taper connections, offer modularity, allowing surgeons to choose different head sizes and neck lengths to optimize patient fit. Surgical Technique: Implantation involves removing the damaged part of the hip joint and replacing it with the prosthetic components. Range of Motion: The design aims to provide stability, durability, and a suitable range of motion for the patient.