Catalog No. : 9SS.303.12R4 To 9SS.303.18L7
Material : Stainless Steel 316L,316LVM,Titanium
Size
Hole Item Code
12MM (R & L)
(Right)
12 MM DEPTH, Holes-4 9SS.303.12R4
12 MM DEPTH, Holes-5 9SS.303.12R5
12 MM DEPTH, Holes-6 9SS.303.12R6
12 MM DEPTH, Holes-7 9SS.303.12R7
(Left)
12 MM DEPTH, Holes-4 9SS.303.12L4
12 MM DEPTH, Holes-5 9SS.303.12L5
12 MM DEPTH, Holes-6 9SS.303.12L6
12 MM DEPTH, Holes-7 9SS.303.12L7
15MM (R & L)
(Right)
15 MM DEPTH, Holes-4 9SS.303.15R4
15 MM DEPTH, Holes-5 9SS.303.15R5
15 MM DEPTH, Holes-6 9SS.303.15R6
15 MM DEPTH, Holes-7 9SS.303.15R7
(Left)
15 MM DEPTH, Holes-4 9SS.303.15L4
15 MM DEPTH, Holes-5 9SS.303.15L5
15 MM DEPTH, Holes-6 9SS.303.15L6
15 MM DEPTH, Holes-7 9SS.303.15L7
18MM (R & L)
(Right)
18 MM DEPTH, Holes-4 9SS.303.18R4
18 MM DEPTH, Holes-5 9SS.303.18R5
18 MM DEPTH, Holes-6 9SS.303.18R6
18 MM DEPTH, Holes-7 9SS.303.18R7
(Left)
18 MM DEPTH, Holes-4 9SS.303.18L4
18 MM DEPTH, Holes-5 9SS.303.18L5
18 MM DEPTH, Holes-6 9SS.303.18L6
18 MM DEPTH, Holes-7 9SS.303.18L7
Technical data: Oxygen flow:0.5-5L/min Oxygen concentration:95.5%-87% Output pressure: 40-70kPa Pressure relief mechanism operational at: 250kPa + 25kPa Operation nose Level
Oxygen Concentrator - 0.5-10L/Min Purityï¼? 96% Compressor Life - 25000hours Sound Level 60dB Screen - LED Segment real-time display Power comsumption - 500VA Net Weight - 23k Gross weight:27kg
Fuel LPG. Fuel Tank Capacity 2.0 L Fuel Consumption : App. 225 g P/H Length : 350 mm Height : 330 mm Width : 150 mm Weight(kg) Empty : 1.5 Kg (Empty)
Catalog No. : 9SS.301.0R03 To 9SS.301.0L08 Material : Stainless Steel 316L,316LVM, Titanium Size Hole Item Code (Right) 3mm 9SS.301.0R03 4mm 9SS.301.0R04 5mm 9SS.301.0R05 6mm 9SS.301.0R06 7mm 9SS.301.0R07 8mm 9SS.301.0R08 (Left) 3mm 9SS.301.0L03 4mm 9SS.301.0L04 5mm 9SS.301.0L05 6mm 9SS.301.0L06 7mm 9SS.301.0L07 8mm 9SS.301.0L08
Supplier: Food product, medical tools , metal scrap , oil
The Zimmer M/L Taper Hip Prosthesis is a product line from Zimmer Biomet, a company that specializes in orthopedic implants and devices. The M/L Taper Hip Prosthesis is used in hip replacement surgeries and consists of a femoral stem that is implanted into the patient's femur. The "M/L 12/14 Taper" designation likely refers to the taper of the femoral stem, with 12/14 indicating the taper size. The "Standard Offset" specification suggests a standard offset design for the femoral stem. The offset refers to the distance between the center of the femoral head and the center of the femoral stem. Standard offset is a common configuration, but there are also variations such as high offset or low offset stems to accommodate different patient anatomies. Key features and considerations for the Zimmer M/L Taper Hip Prosthesis may include: Material: The femoral stem is typically made of biocompatible materials such as titanium or cobalt-chromium alloy. Taper Design: The taper design facilitates the connection between the femoral stem and the femoral head component. Modularity: Some hip prostheses, including those with taper connections, offer modularity, allowing surgeons to choose different head sizes and neck lengths to optimize patient fit. Surgical Technique: Implantation involves removing the damaged part of the hip joint and replacing it with the prosthetic components. Range of Motion: The design aims to provide stability, durability, and a suitable range of motion for the patient.
Thumb plate (tubular type) AJY-S03 For the first metacarpophalangeal joint, thumb phalanx, metacarpal fracture and wrist dislocation fixation. 210*145*3.2mm LOW TEMPERATURE THERMOPLASTIC SHEET Product features: Low temperature thermoplastic sheet is a new type of material made of specially synthesized polymer polycaprolactone treated by a series of chemical methods. Molecules are in a stable state at room temperature (10-30C), and can be softened after being heated in 65-70C water for 1-3 minutes. Curing in 3-5 minutes at room temperature. It has the advantages of light weight, high strength, good air permeability, not afraid of water, non-toxic, odorless, non-irritating to the skin, etc., and has biodegradability. Scope of application: 1. Fixation after reduction of fractures and joint dislocations 2. Postoperative fixation of soft tissue injuries such as joint ligaments, nerve and tendon injuries 3. Bone, joint tuberculosis, acute and chronic osteomyelitis, septic arthritis, primary bone Fixation during conservative treatment such as tumor metastasis or after debridement 4. Joint deformity, nerve palsy, cerebral palsy, scoliosis correction and postoperative fixation in children and fixed 5. Fixation after burns and other plastic surgery operations 6. Production and application of rehabilitation braces and orthoses 7. Posture placement and fixation during radiotherapy