Fresenius fx8 dialyzer is a part of FX Series dialyzer. Its a single use dialyzer.
Fx8 Dialyzer are based on optimized and redefine handling. There are several high end technologies have been combined to provide the distinctive functional feature of FX dialyzer. The structure of fibre bundle, membrane ,flow port and housing design provide the performance of the dialyzer along with safety and handling. The optimal membrane permeability design gives minimal loss of blood components. It gives homogeneous blood flow inside the dialyzer.
Sterile Hypodermic Syringes with Needle for Single Use
US$ 0.5 / Carton Get Freight Cost Calculate Margin
10000 Cartons Minimum Order : 20 - 90 days
Product Details
Model Number : ZS-05- H-SY 5ML-#3409
Brand Name : Winhealth
Origin : China (mainland)
Small Orders : Accepted
Key Specifications/Special Features:
Model No. ZS-01-H-SY 1ML, 3 ML, 5ML
Brand Name: Winhealth
Origin: China
CE Approval
Fast Delivery for Any Quantity
Sterilization Independent Packaging
Using Independent packaging ,after ethylene oxide sterilization, open ready tp use.
All Sterile EO Processing with Single Blister Pack with Needle Pre-attached
Different Sizes: 1ML, 3ML, 5ML
Shipping Information:
FOB Port: Shanghai Lead Time : 20 - 90 days
HTS Code : 9018.31.00
Dimensions per Unit : 15 X 3 X 3 Centimeters
Weight per Unit : 7 Grams Units per Export
Carton : 1600 Export Carton
Dimensions L/W/H: 48.5 X 40.5 X 45 Centimeters Export Carton
Weight : 8.5 Kilograms
Main Export Markets:
Asia
asia
Central/South America
Eastern Europe
Mid East/Africa
North America
Western Europe
Any third-party trademarks or images shown here are for reference purposes only. We are not authorized to sell any items bearing such trademarks.
Payment Details:
Payment Method : Telegraphic Transfer in Advance (Advance TT, T/T)
The item is in its original condition and no alterations have been made to the item.
The item has been properly stored and handled, following the manufacturers recommendations.
The item comes with the accessories specifically mentioned in the description or shown in the pictures.
This item is not a food or medical product that has expired.
This item does not appear to be damaged or mishandled.
To the best of seller’s knowledge the item has not been recalled.
FDA REGULATION AND CERTIFICATION:
· The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, do not bid on this item unless you are an authorized purchaser. If the item is subject to FDA regulation, I will verify your status as an authorized purchaser of this item before shipping of the item.
· If you have questions about legal obligations regarding sales of medical devices, you should consult with the FDA's Center for Devices and Radiological Health:
Quick Details
Pressure : High
Place of Origin : Hubei, China
Model Number : 20Mpa-356(7.7)mm-150L CNG Compressed Natural Gas
Material : Steel, 34CrMo4 Steel
Brand Name : SINOGES or OEM Branded
Use : Vehicle Mother Station Transport
Application : Vehicle Mother Station Transport
Working pressure : 20 MPa | 200 Bar | 2901 psi
Test Pressure : 37.5 MPa | 375 Bar | 5439 psi
Outer Diameter : 356 mm | 14 inch
Wall Thickness : 7.7 mm | 0.3 inch
Water capacity : 150 L | 9154 in3
Cylinder Height : 1851 mm | 72.9 inch
Cylinder Weight : 141.1 kg | 311 lb
Certification : ISO 9809-1 TPED
Supply Ability
Supply Ability : 2646 Piece/Pieces per Week
Packaging & Delivery
Packaging Details : Wood Pallet Packing
Port : Shanghai
Picture Example : package-imgpackage-img
Lead Time:
Quantity(Pieces) 1 - 1 2 - 378 379 - 1134 >1134
Est. Time(days) 15 35 45 To be negotiated
Features and Benefits
Sterile pack, single use only.
Needle-stick prevention, safety assured.
Special needle tip design to prevent rubber fragment contamination.
Luer connector, equipped with needleless connector, heparin cap, Y three-way.
Chassis sponge design for a more comfortable application.
High pressure resistant central line with 325 P.S.I
Two holes connector optional.
MDR 2017/745
USA FDA 510K
Refer Standards
ISO 10555-6:2015 Intravascular catheters - Sterile and single-use catheters Part 6: Subcutaneous implanted ports.
ISO 8536-4: 2010 Infusion equipment medical use- Part 4: Infusion Sets for single use, gravity feed.
ISO 23908:2011 Sharps injury protection Requirements and test methods - Sharps protection features for single-use hypodermic needles, introducers for catheters and needles used for blood Samplings.
ISO 7864:2016 Sterile Hypodemic Needles for Single-use requirements and test methods.
ISO 9626:2016 Stainless Steel Needle Tubing for the Manufacture of Medical Devices requirements and Test methods.
ISO 80369-7: 2016 Small - bore connectors for liquids and gases in healthcare applications.
Part 7: Connectors for intravascular or hypodermic applications.
ISO 10993-7:2008 Biological Evaluation of Medical Device - Part 7: Ethylene Oxide Sterilization Residuals.
Refer Standards
ISO 9626: 1991 + AMENDMENT 1 2001 Stainless steel needle tubing for the manufacture of medical devices.
ISO 8537:2007 Sterile single-use syringes, with or without needle, for insulin.
ISO 10993-7:2008 Biological evaluation of medical devices - Part 7 : Ethylene oxide sterilization residuals.
ASTM F 1140/F 1140M-13 Standard test methods for internal pressurization failure resistance of unrestrained packages.
USP 37-NF 32 <85> Bacterial Endotoxins Limit.
ISO 11737-2:2009 Sterilization of medical devices - Microbiological methods - Part 2: Test of sterility performed in the definition, validation and maintenance of a sterilization process.
ISO 11135-1:2007 Sterilization of health care products - Ethylene oxide - Part 1: Requirements for development, validation and routine control of a sterilization process for medical devices.
Minimum Order Quantity 100 Piece
Brand Protectmed
Material Non Woven
Color White
Usage/Application Hospital
Gender Unisex
Size S,M,L,XL,XXL
Disposability Disposable
Wash Care Machine Wash
GSM 45 GSM
Pattern Plain
Country of Origin Made in India
We are offering Disposable Coverall Suit to our Clients We are leading manufacturers Disposable Product
Request
Callback
Additional Information:
Production Capacity: 2000 per day
Delivery Time: 2 Day
Packaging Details: single packing
The manual steering system is the device that a helm pump driven by the rotation of the steering wheel supplies oil to the cylinder and pushes the piston of the cylinder to have the rudder shaft move.
It is a simple system consisting of a helm pump and a cylinder.
Cylinder has 4 types of single, rotary, twin, and two rudder.
D-I offers the best options to combine kinds of help pumps and cylinders.
Our choice mostly satisfies customers, but in case of your special needs, you have many optional ways.
The number of rotation wheels is defined by the capacity of the cylinder and the helm pump (cc/rev).
You can select the specification you want.
Key features
Simple system
2 helm pumpsâ??below 50cc, above 50cc
Compatible with commercial handles in the range of 300 mm to 1,500 mm
Dual handle installation is possible.
The lock valve is supplied as default, which can fix the rudder where the handle stops.
Structure that the rudder does not rotate even when the tide powers the rudder
Rudder angle indicator attachable
Application
Suitable for vessels below 500 HP
A range of vessels from leisure ships, fishing boats, commercial boats, and passenger boats