Product Details:
Form Cassette
Brand Abbott
Country of Origin Made in India
To perform a test with i-STAT single-use cartridges, 2 to 3 drops of blood are applied to a cartridge, which is then inserted into an i-STAT 1 or i-STAT Alinity blood analyser. Results are available in approximately 2 minutes for most tests. The i-STAT System allows clinicians to stay with the patient to perform diagnostic testing to help accelerate clinical decisions and time to treatment.
Product Details: Instrument Name Blood Analyser Automation Fully Automatic Brand Abbott Sample Mode Whole Blood We are a top-notch supplier of Abbott i-STAT 300 Handheld Blood Analyzer. Provide lab-quality results in minutes for faster patient care: The easy-to-use Abbott i-STAT handheld operates with the advanced technology of single-use i-STAT test cartridges. Together, they create the i-STAT System a point of care (POC) system that provides lab-quality results in minutes and allows healthcare professionals to quickly respond to needs and conditions at the patient's side. Benefits and features of the i-STAT System: Simple to use: Only four steps required to get patient results in less time and at less cost Faster results than benchtops: Studies have shown that the i-STAT System is significantly quicker than bench-top systems and the central lab Patient-centered care: i-STAT enhances patient satisfaction by minimizing wait times and length of stay Broad test menu: Single-use i-STAT test cartridges cover a large menu of commonly used tests in one platform Streamlined information management: Data Management Software, Advanced Quality Features, and statutes help integrate test results into your facility's software Additional Information: Delivery Time: 1 Packaging Details: box
Troponin I (CTnI) One Step Rapid Test Kit (Whole blood/serum/plasma) Product description Product name: CTnI One Step Troponin I Rapid Test Kit Specification: Lateral-flow Immunofluorescence Chromatographic Assay 10 pcs, 25 pcs, 50 pcs, 100 pcs/box, or customized Type: Cassette MOQ: 10,000 PCS Analytical Range: 1.0~50ng/ml (Whole Blood); 0.1~50ng/ml (Serum/Plasma) Specimen: Human serum/plasma/whole blood Manufacturer: Hangzhou Laihe Biotech Co., Ltd. 2.Clinical significance (1)Diagnosis of various chest pain (2)Foundation of ACS diagnosis and risk stratification (3)Best markers for ACS prognosis (4)An aid in the diagnosis of myocardial infarction (injury) (5)Can improve clinical, economic and operational outcomes
One Step Troponin Test (Whole blood/Serum/Plasma FOR IN VITRO DIAGNOSTIC USE ONLY SPECIMEN COLLECTION 1. Testing should be performed immediately after the specimens have been collected. Do not leave the specimens at room temperature for prolonged periods. Specimens may be stored at 2-8C for up to 3 days. For long-term storage, specimens should be kept below -20C. 2. Bring specimens to room temperature prior to testing. Frozen specimens must be completely thawed and mixed well prior to testing. Specimens should not be frozen and thawed repeatedly. MATERIALS PROVIDED 1. Test cards individually foil pouched with a desiccant 2. Plastic dropper 3. Package insert MATERIALS REQUIRED BUT NOT PROVIDED 1. Timer/clock 2. Pipette 3. Controls ASSAY PROCEDURE 1. Read package insert carefully before testing. Allow the test devices, whole blood, serum or plasma to equilibrate to room temperature (15-30C) prior to testing. Do not open pouches until ready to perform the assay. 2. Remove the test device from the foil pouch and use it as soon as possible. 3. Place the test device on a clean and level surface. Hold the dropper provided vertically and transfer 3 drops of specimen (100�µl) to the specimen well (S) in the test device. 4. Wait for the red line(s) to appear. The result should be read between 10 to 15 minutes. INTERPRETATION OF RESULTS 1. Positive Two colored lines should be observed in the viewing window. The line in the test region (T) is the probe line; the line in the control region (C) is the control line, which is used to indicate proper performance of the device. The color intensity of the test line may be weaker or stronger than that of the control line. 2. Negative The control line appears in the test window, but the test line is not visible. 3. Invalid No line appears in the control region. Under no circumstances should a positive sample be identified until the control line forms in the viewing area. If the control line does not form, the test result is inconclusive and the assay should be repeated.
General Information One-Step Troponin I /CK-MB/ Myoglobin Rapid Test is intended for the qualitative determination of cardiac disease in human serum, plasma or whole blood.
HIV I&II Rapid Test
Product Details: Brand : Boditech Med Incorporated Size : 25 T Samples : Human whole blood/serum/ plasma Sample volume : 50 Microliter stored at 4 - 30 DegreeC Cat No : CFPC-65 Troponin I (Tn-I) Plus Early diagnosis of myocardial infarction with high sensitivity Troponin I (Tn-I) Plus can diagnose myocardial infarction and myocardial necrosis at an early stage with high sensitivity by accessing Tn-I level in the blood, thus can help prevent progression to more severe cases. INTENDED USE: ichroma Tn-I Plus is a Fluorescence Immunoassay (FIA) for the quantitative determination of cardiac troponin-I (Tn-I) in human whole blood/serum/plasma. It is useful as an aid in management and monitoring of acute myocardial infarction (AMI). For in vitro diagnostic use only. PRINCIPLE : The test uses a sandwich immunodetection method; the detector antibodies in buffer bind to antigens in the sample, forming antigen-antibody complexes, and migrate onto nitrocellulose matrix to be captured by the other immobilized-antibodies on test strip. More antigens in the sample will form more antigen-antibody complexes which lead to stronger fluorescence signal by detector antibodies, which is processed by instrument for ichromaâ?¢ tests to show Tn-I concentration in the sample. MATERIALS SUPPLIED : REF CFPC-65 Components of ichroma Tn-I Plus Cartridge Box: - Cartridge 25 - 50L Capillary tube 25 - ID chip 1 - Instruction for Use 1 Buffer Box For ichorma II - Detector (Capped with plastic lid) 25 - Diluent 1 For ichroma 50 - Detector (Sealed with aluminum foil) 25 - Diluent 1
Hello, I have FDA approved rapid COVID 19 testing kit. Price 6$, all the certificates and the documents are Available
Professional's Deluxe High Quality Acoustic Sensitivity Stethoscope for Medical Students & Doctors High Quality Hospital Medical Black Stainless Steel Stethoscope PRODUCT INFO High Quality Hot Sale Hospital Medical Black Stainless Steel Stethoscope Product Details Place of Origin: INDIA Brand Name:Sign For Safety Model Number:SFS-101A Power Source:manual Warranty:1 Year After-sale Service:Online technical support Material:Zinc alloy head Shelf Life:1years Quality Certification:ce Instrument classification:Class I Safety standard:EN 149 -2001+A1-2009 Product name:Stethoscope Certificate:CE/ ISO9001/ ISO13485 Safety standrard:EN 149 -2001+A1-2009 Color:Black Usage:Medical Test Tube:PVC (multicolor) Head:Zinc alloy Single gross weight:0.400 kg Single package size:30X14X6 cm Optional:PVC Tube Color or Put Logos Packaging Details Color Box Standard Export Carton
Extremity Drape, EO Sterile, Material: SMMS 45g, SM/PE 100gsm Size: 220*318CM, Elastic Fenestration, Absorbent Reinforcement, Tube Holders Blue: Color Product Specifications: Model Number: SFS-SM-907 Properties : Medical Protection Size:220*318CM Shelf Life:3 years Material : SMMS, SM/PE, SMMS, SM/PE Quality Certification : CE, ISO13485, EO0197 Instrument classification: Class I Safety standard:ISO13485 Style : Single use Application: Surgical infection Feature : Breathable, comfortable, anti-statics Test report : CE, ISO13485, EO0197 MOQ:100 Supply Ability 100000 Piece/Pieces per Month Packaging & Delivery Packaging Details 1pcs/paper pouch, 20pcs/ctn