Please click here to check who's online and chat with them.

Ac Resonant Test System

Supplier From China
Aug-10-22

Overview

This device is designed and manufactured for 35kV cable AC withstand voltage test. The reactor is individually designed for multiple units, which can not only meet the test conditions of high-voltage and low-current equipment, but also meet the low-voltage AC withstand voltage test requirements of 10kV cables.

The special AC resonance test system for cables adopts the method of adjusting the frequency of the power supply, so that the reactor and the capacitor under test can achieve resonance, and the high voltage and large current can be obtained on the test product. It is a new method of current high voltage test and The trend has been widely used at home and abroad.

The AC resonance test system uses a dedicated SPWM digital waveform generator chip with a frequency resolution of 16 bits, and the frequency fineness can reach 0.1 Hz at 20 to 300 Hz; it adopts an orthogonal non-synchronous fixed carrier modulation method to ensure that the entire frequency The output waveform is good in the interval; the advanced IPM module is used in the power part to ensure the stability and safety of the instrument under the minimum weight.

The test system consists of a frequency and voltage regulation power supply, an excitation transformer, a reactor, and a capacitor divider.

Technical index

1. the resonant excitation power supply only needs 1/Q of test capacity, which is 1/10-1/30 of common test unit and reduces the system weight and volume greatly.

2. Rated voltage:

1.108kV meeting the alternating current withstand voltage test for 35kV cable;

2.Waveform distortion rate of output voltage should be less than 1.0

3.The permissible continuous working time is to work for 5 minutes at one time under rated condition.

4.Quality factor of unit itself: Q 50



Advantage

1.The power capacity needed is reduced greatly.

2.The weight and volume of equipment is reduced greatly.

3.The waveform of output voltage is improved.

4.The large short-circuit current is prevented from burning fault point.



Feature:

1. A large number of cables with voltage levels of 35kV and below are used, and the test workload is large, so this type of withstand voltage test device is small in size and light in weight, and a portable cable withstand voltage test system was born;

2. This system requires that the weight of the parts that a single person can move on-site does not exceed 30kg, and the weight of the parts that two people can move on-site does not exceed 60kg, which is suitable for on-site transportation;

3. The power supply adopts 220V single-phase power supply or 380V single-phase power supply, which is convenient for on-site power supply;

4. The reactor part is made of dry epoxy casting, which is beautiful and reliable, suitable for the requirements of various cables;

5. The withstand voltage test of 110kV and above cables adopts oil-immersed reactors.


Recent User Reviews

This user has not received any reviews yet!

Verification Status


 
 
Contact Supplier
Renew

More Items Similiar to: Ac Resonant Test System

Aug-04-21

Ac Resonant Test System For Cvt

$770.00 - $15.4k
MOQ: Not Specified
 
Product Introduction
Capacitive voltage transformer (CVT) in calibration the test must be conducted under the condition of 50Hz frequency complex geographical condition on site at the same time the traditional experiment device is difficult to meet the requirements of on-site handling testing series resonance booster device is first used in domestic field tunable resonance device has been widely used in domestic 500 kv and below the field calibration of capacitor voltage transformer.



Product Parameters
Technical parameters
Rated Capacity 80kVA
rated voltage 160kV
Adjustable inductance range 65~130H
Rated frequency 50Hz
Rated current 0.5A
Adjustable gap range 0~300mm
Product Characteristics
1 Due to full compensation of resonant reactive power the power of power supply and equipment is less than 1/10 of the required capacity of the subject (1/Q>10). Small size and light weight with the same capacity large output capacity of the device and small power capacity required cheap convenient and safe to use;

2 Series resonance is actually a current filtering circuit so that the current passing through the subject is basically the fundamental current and the waveform distortion rate (THD) of the output voltage is very small which is superior to all existing ac voltage withstand equipment.

3 The short circuit current of the sample after flashover or breakdown is only less than 1/10 (1/Q) of the test current before short circuit which can effectively prevent the expansion of damage to the fault point after breakdown;

4 After flashover the arc will be automatically extinguished immediately. The long (number of seconds) process of restoring resonant state voltage after arc quenching is a steady-state establishment process and there is no danger of voltage overshoot and no danger of restoring overvoltage in microsecond millisecond transient process.
Jul-31-21
 
Product Introduction
Capacitive voltage transformer (CVT) in calibration the test must be conducted under the condition of 50Hz frequency complex geographical condition on site at the same time the traditional experiment device is difficult to meet the requirements of on-site handling testing series resonance booster device is first used in domestic field tunable resonance device has been widely used in domestic 500 kv and below the field calibration of capacitor voltage transformer.


Product Parameters
Technical parameters
Rated Capacity 80kVA
rated voltage 160kV
Adjustable inductance range 65~130H
Rated frequency 50Hz
Rated current 0.5A
Adjustable gap range 0~300mm
Jul-23-21

Tkbpxz-H Ac Resonant Test System

$770.00 - $15.4k
MOQ: Not Specified
 
Capacitive voltage transformer (CVT) in calibration the test must be conducted under the condition of 50Hz frequency complex geographical condition on site at the same time the traditional experiment device is difficult to meet the requirements of on-site handling testing series resonance booster device is first used in domestic field tunable resonance device has been widely used in domestic 500 kv and below the field calibration of capacitor voltage transformer.
Product Characteristics
1 Due to full compensation of resonant reactive power the power of power supply and equipment is less than 1/10 of the required capacity of the subject (1/Q>10). Small size and light weight with the same capacity large output capacity of the device and small power capacity required cheap convenient and safe to use;

2 Series resonance is actually a current filtering circuit so that the current passing through the subject is basically the fundamental current and the waveform distortion rate (THD) of the output voltage is very small which is superior to all existing ac voltage withstand equipment.

3 The short circuit current of the sample after flashover or breakdown is only less than 1/10 (1/Q) of the test current before short circuit which can effectively prevent the expansion of damage to the fault point after breakdown;

4 After flashover the arc will be automatically extinguished immediately. The long (number of seconds) process of restoring resonant state voltage after arc quenching is a steady-state establishment process and there is no danger of voltage overshoot and no danger of restoring overvoltage in microsecond millisecond transient process.
GOLD Member
Jan-29-23

Grid Renewable Energy Storage 50Kw/75Kwh

$40.3k
MOQ: 1  Sets
Sample Available
 
GRES is an intelligent and modular power supply equipment integrating lithium battery and MPCS. According to different application scenarios, lithium battery, bidirectional DC / AC converter, bidirectional DC / DC converter, Static switch and Power management system can be arbitrarily combined to realize grid connected power supply, off grid power supply and off grid uninterrupted power supply power supply, static reactive power compensation, harmonic suppression and other functions. The system can have access to new energy, power grid, diesel generator and to rreasonable configuration, scientific utilization, to provide users with green, environmental protection, noise free, high reliability and
high security power services.

Safe and reliable
High quality li-ion cell for mobile use
Laser welding connection with high strength and low impedance
Cells is designed with PC holders and reinforce steel structure to guarantee the highest safety of the system in transportation, installation and operation
Damping pad design to improve the impact resistance of the system
IP54 safe and reliable operation in outdoor environment
Serially designed PCS and battery pack eliminates circulating current and improve system reliability.
Integrated BMS,DC, AC multi-layer protection, maximum safety performance design

Efficient and Convenient
Integrated system, standard modular power module and battery module, easy for installation, maintenance and capacity expantion
Easy access to PV and diesel generator, intelligent muli-energy management.
Fixed on the ground or mounted on vehicle, can be loaded and unloaded by forklift and hoisted by lifting ring
Multi systems could be connected in parallel

Cost optimization
One investment, multiple benefits:Peak shaving, backup power supply, microgrid building,power quality improving and energy storage,etc.
Small size, light weight, less space and installation cost
Long cycle life, low failure rate, reduce operation and maintenance investment
Maximize green energy utilization.


Rated output power: 50KW
Rated energy: 75KWH
Apr-29-22
 
Frequency conversion series resonance test device is designed and manufactured for alternating-current withstand voltage test of Possessing a wider application scope, it is the ideal withstand voltage equipment for prefecture-level, municipal-level and county-level high-voltage test departements as well as power installation and repair & testing engineering units.

Frequency Conversion Series Resonance Test Device

(I) Technical index

1. Rated voltage:

2. Quality factor under full load in test of fire power generator: Q10 (relating to load)

3. Quality factor under full load in cable test: Q 30 (relating to load)

4. Quality factor under full load in test of main transformer: Q 30 (relating to load)

5. GIS, the quality factor under full load in switch test and other tests: Q 50 (relating to load)

6. Input power supply: single phase of 380V

7. Frequency adjustment range: 20Hz 300Hz

8. Accuracy of system measurement: 1.5

9. The unit possesses protective functions, such as over voltage, over current and zero start.



(II) Description for main configuration and technical data of equipment:

1. One set of variable-frequency power supply:

Rated power: 10kVA;

Input voltage: single phrase of 220V or three phase of 380V 10% and 45 65Hz

Output voltage: 0 400V adjustable

Output voltage frequency: 30 300Hz

0.1Hz adjustable stepping

Instability degree of frequency 0.02%

Output current: 0 25A

2. High-voltage resonane reactor (4sets in all): 27kV/1A

Rated working voltage: 27kV

Rated working current: 1A

Rated inductance value: 120H

Continuous working time: 60min

Temperature rise should be less than 60

Working frequency: 30- 300Hz

3. One set of exciting transformer:

Rated capacity: 10kVA

Input voltage: 400V

Output voltage: 1.2kV/3kV/5kV
Dec-26-19
 
DC voltage test system
DC test systems are used to test components and complete systems found in electrical power supply systems and operating on DC voltage. POWERHV DC voltage test systems fulfill the requirements of IEC 60060-1.

The DC voltage test systems can be equipped with polarity reversal.
Applications
High-voltage DC testing for transformers, cables, bushings, switchgears, etc.
Wet and pollution testing
DC current measurements at high-voltage potential
For use indoors and outdoors or modular system for onsite testing
For test and research of DC transmission line corona, radio interference, pollution flashover.
Main components:
DC High Voltage Test System 
Series ZL
up to 2400 KV
up to 1 A
DC HV measuring system
Series DZF 
DC voltage divider
up to 2400 KV
Control system( manual operation or computer-aided automatic systems)
Additional features and accessories:
Fast polarity reversal
Bipolar test systems
Controlled power supply to reduce voltage drop
Moveable design
made solution upon customer's request
Jul-31-21

Variable Frequency Series Ac Resonant Test

$770.00 - $15.4k
MOQ: Not Specified
 
Product Description:

Transformer GIS SF6 switch CT/PT insulator bus bar cable bushing and others capacitive devices are the common primary electric equipments.

The complete set of frequency conversion series resonance test equipment is mainly used for ac withstand voltage test of cross-linked cable hydraulic generator main transformer bus GIS etc.
The complete set of frequency conversion series resonance test equipment is mainly composed of frequency conversion control power supply excitation transformer reactor capacitor voltage divider and compensation capacitor (optional).


Product Parameters:
technical parameter

Rated output voltage 0 1000kV and below
output frequency 30 300Hz
Resonance voltage waveform Pure sine wave waveform distortion rate 1.0%
Working time Full power continuous working time of 60min
Quality factor 30~90
Frequency regulation sensitivity 0.1Hz
Instability 0.05%
Working power supply Single-phase 220V or three-phase 380V ±10%
Power frequency 50Hz ±5%
Jun-19-21

Variable Frequency Series Ac Resonant Test

$770.00 - $15.4k
MOQ: Not Specified
 
Product Description:

Transformer GIS SF6 switch CT/PT insulator bus bar cable bushing and others capacitive devices are the common primary electric equipments.

The complete set of frequency conversion series resonance test equipment is mainly used for ac withstand voltage test of cross-linked cable hydraulic generator main transformer bus GIS etc.
The complete set of frequency conversion series resonance test equipment is mainly composed of frequency conversion control power supply excitation transformer reactor capacitor voltage divider and compensation capacitor (optional).
Jan-20-22

Dc Cable Test System

$770.00 - $15.4k
MOQ: Not Specified
 
Product description
120KV 10ma DC Cable Test System is an important equipment for DC voltage withstand test and leakage current test of HV electrical equipments, cables, surge arresters in electriv industry and power supply departments. 120KV 10ma DC Cable Test System is developed based on the calibration made by National HV Meterage Station, it accords with the standard "Generation Requirement of Portable HVDC Generator"(ZGF 24003-90)

Technique Index

1. power: AC220V+10%, 50Hz+1%

2. Output voltage indicator accuracy:

Verification Status