Product Name
Glycosylated Hemoglobin(HbA1c)Test Kit (Immunofluorescence Chromatography)
Purpose
To detect the content of HbA1c in human whole blood in vitro quantitatively.For Professional Use only.
Principles of Detection
The HbA1c Test is a fluorescent lateral flow immunoassay. The test consists of: 1) a conjugate pad containing HbA1c antibody conjugated with fluorescent microspheres and a control antibody (goat anti-chicken IgY antibody) conjugated with fluorescence microspheres, 2) a nitrocellulose membrane strip containing a test line (T line) and a control line (C line). The T line is pre-coated with another HbA1c antibody, and the C line is pre-coated with a control line antibody (chicken IgY antibody).
HbA1c concentration in specimen is positively correlated with the fluorescent density of the microspheres, after the measure and calculation of the quantitative fluorescence immunoassay analyzer, then the analyzer would calculate the concentration of HbA1c according to the preset calibration curve in the machine and display the result, detection unit is %units. C line should appear in any cases, which indicates the reaction system is effective.
Storage conditions and shelf life
Store in a sealed aluminum foil bag at 2~30�°C. After unpacking the aluminum foil bag under temperature 20~30 �ºC , humidity 35~65%, please use it immediately.
Shelf life 18 months.
Applicable instrument
Avid fluorescent immunoanalyzer model: AI-IF 600
Manufacturer& After-Sales Company: Shenzhen Aivd Biotechnology Co., LTD.
Address:C501,Building B5,China Merchants Guangming Science Park, #3009 Guanguang Road, Guangming District, Shenzhen,Guangdong Province, China
Tel: 0755-26165742 Fax:0755-26401805
Specimen collection and preparation
1. Human whole blood samples can be used for this test.
2. Specimen collection:Collect blood specimen into a collection tube containing EDTA , evenly mixed before use. Do not use hemolyzed blood for testing.
Whole blood specimens should be stored at 2-8�°C for no more than 4 hours if not test immediately.
3. Do not test patients' samples with severe hemolysis, lipemia and jaundice, all specimens should be treated as infectant.
4. Restore the specimen to 20-30�°C before the detection, cryopreserved specimen should be completely thawed, rewarmed and evenly mixed before use.
Reference range
Positive: reading value â?¥6%, a positive result.
Negative: reading value 8%, poorly controlled blood glucose.
The reference value is verified with reference to similar products that have been marketed. Due to ethnic and geographical differences, each laboratory can establish its own reference interval according to the actual situation.
Product Name Triiodothyronine (T3) Test Kit (Immunofluorescence Chromatography) Purpose To detect the content of T3 in human plasma/serum/whole blood in vitro quantitatively.For Professional Use only. Principles of Detection The T3 Test is a fluorescent lateral flow immunoassay. The test consists of: 1) a conjugate pad containing T3 antibody conjugated with fluorescent microspheres and a control antibody (goat anti-chicken IgY antibody) conjugated with fluorescence microspheres, 2) a nitrocellulose membrane strip containing a test line (T line) and a control line (C line). The T line is pre-coated with another T3 antigen, and the C line is pre-coated with a control line antibody (chicken IgY antibody). T3 concentration in specimen is positively correlated with the fluorescent density of the microspheres, after the measure and calculation of the quantitative fluorescence immunoassay analyzer, then the analyzer would calculate the concentration of T3 according to the preset calibration curve in the machine and display the result, detection unit is nmol/mL. C line should appear in any cases, which indicates the reaction system is effective. Storage conditions and shelf life Store in a sealed aluminum foil bag at 2~30�°C. After unpacking the aluminum foil bag under temperature 20~30 �ºC , humidity 35~65%, please use it immediately. Shelf life 18 months. Reference range Reference value:The 95% concentrations of T3 in 239 non-stationary subjects without any obvious thyroid dysfunction ranged from 1.34 to 2.73nmol/L, with a median of 1.81nmol/L;The reference value has been verified with reference to similar products already on the market. Each laboratory can build own reference range according to actual situation.
- Can see the results in a short time 30 min. - More convenient than using blood. - Rapid production and supply are possible. - Convenient for personal use or at home. - Sensitivity 95% - Certified For EUROP And USA - Min order Discussed, Quote First - Fast delivery all Around the world By DHL FEDEX - In stock Korea by OTG. * Can supply Blood type Rapid test kit avail
Blood glucose testing strip designed to eliminate the risk of a false reading by checking each sample twice. one Touch Ultra 100 Test Strips is a brilliant diabetic care product for diabetic patient to examine the blood sugar level on a regular basis and keep a check on it. The pack consists of 50 blood glucose monitoring strips. The Onetouch Ultra 2 is one of the best in class glucometers which makes self-monitoring of blood glucose very easy. OEM Meter Diabetes Sensor Blood Glucose Test Strips Packing:24Sets / CTN CTN Dimension:37X32.5X20.5CM G.W:4.7 KGs N.W:4.2 KGs
Sleep Better Drug Free Opens Your Nose to Relieve Nasal Congestion. It's simple Flexible, "spring-like" bands gently lift nasal passages open90% of people felt they could breathe better instantly. The only strip with 3M adhesive to hold strip comfortably in place Breathe Right nasal strips open your nose to help you breathe better so you can sleep better. Use every night if you suffer from: Nasal Congestion due to Allergies, Colds, or Deviated Septum Snoring Get the right size for best results Large - for an adult with a larger nose Sm/Med - fits 75% of adult noses Breathe Right Nasal Strips, Large Works instantly Use for Relief from Nasal
With a Freestyle Libre Sensor you can continuously measure your blood sugar for 14 days. Attaching the sensor using the sensor applicator is well described in the instructions for use. When attaching the sensor, a small, 5mm long, flexible cannula is placed under the skin (usually painless). The sensor is worn on the back of the upper arm and continuously measures your glucose levels. It is waterproof and can be worn while bathing, showering or swimming. If you set up additional optional alarms, you will be warned in good time about hypoglycemia, for example, and can therefore feel even safer - day and night.