Specification
- Full-spectrum wavelength range: 300-1100nm or 350-1000nm (PTC)
- Wavelength range can be extented to 1700nm or more.
- Single wavelength source: 470nm, 530nm, 630nm, 940nm (+/-5nm) or customized
- Dynamic Range: 80dB ,100dB, or 140dB
- Test fixtures: DUT
Supplier: Auto circuit tester professional, auto wire stripper, combination tool, digital voltage tester, general tester, voltage sensor, screw driver & bit sets, utility knife, voltage sensor, cable tie
Supplier: Industrial process & control products like multi-function meter, lt current transformers, power quality analyzers, temperature controllers, electrical transducers, power supplies, energy meters, analog & digital panel meters, dc converters, temperature sensors, recorders, temperature and humidity monitor, ultrasonic level transducer, testing & measuring instruments, digital multimeters, ac/dc clamp meters, insulation testers, earth testers, power clamp meters
Services: Export
Specification - High stable Xe white light source: Color temperature: 5,500k - 6,000K Optical instability =250 lux Green light: peak@550nm+/-5nm; >=300 lux Blue light: peak@475nm+/-5nm; >=100 lux - White light intensity: >= 8,000 lux - Light intensity adjustment: 0~100% with 0.1% resolution Max 4-order light intensity dynamic range Application - Optical Fingerprint Sensor testing - Development of Fingerprint Recognition Algorithm in ISP Chip - Sensor Properties test and analyze - Analyze the image qualities of the Optical Sensor Module
Supplier: We are at gr analytical solution ,providing gc, hplc,uplc,gcms,gchs,uv, ftir aas and icp, our office is located at bill road, vadodara. the company was established in the year 2016 and we have been dedicated in offering top quality analytical consumables used in laboratories for different instruments like gc, hplc and uv spectrophotometer and maintenance services for the same.
we are offering the refurbished analytical instruments like gc,hplc,uv,ftir,aas and icp.
Buyer: We are buy the refurbished analytical instrument like gas chromatograph, hplc,uv spectrophotometer, aas and icp.
Film Shrinkage Test Equipment Film Shrinkage Tester GBK-D1 Film Shrinkage test, known as linear thermal shrink test or free shrink test, is used for analyzing the effect of temperature on heat shrinkable films made from polyethylene, ethylene copolymers and their mixtures. Basically, shrinking force, contracting force and shrinking ratio can be measured in such determination. GBPI Film Shrinkage tester conforms to the multiple national and international standards: ASTM D2732 - Standard Test Method for Unrestrained Linear Thermal Shrinkage of Plastic Film and Sheeting ISO 14616 - Plastics Heatshrinkable films of polyethylene, ethylene copolymers and their mixtures Determination of shrinkage stress and contraction stress DIN 53369 - Testing of plastic films determination of the shrinking stress Film Shrinkage Test Equipment GBK-D1 is used to determination of the degree of unrestrained linear thermal shrinkage and dimensional stability at different temperatures. Widely used in industries of plastic material, plastic products, petroleum, chemicals, research institute, inspection agency and so on. Principle This tester uses the principle of air heating to connect the tested sample to the tension sensor and displacement sensor. After reaching the maximum shrinkage force, it is placed in an external test environment with an ambient temperature of 23 to cool down. The reference temperature, shrinkage force and displacement are recorded, and the recorded data can be used to determine the optimal shrinkage conditions of the film. Standards ISO 14616, ASTM D2732, DIN 53369
Product Introduction SF6 intelligent micro water quality tester is developed and designed according to the national power industry standard DL t506 2007 insulation gas humidity measurement method for sulfur hexafluoride electrical equipment and adopts the imported high precision dew point sensor and new digital circuit control technology. It is a high-precision intelligent instrument to measure the trace moisture content in SF6 gas. This instrument adopts intelligent self calibration technology wide measurement range fast response high accuracy good linearity dynamic display of measurement curve. At the same time the instrument also has an automatic dryer which can greatly reduce the measurement time. Technical Parameters Measuring range Dew point value 80 20 Moisture content 0 19999uLL Accuracy of measurement 0.5 60 20 1.0 80 60 The resolution of the Dew point value 0.1 Moisture content 1uLL Response time 20 0.1mpa 63 needs 5s 90 needs 45s 60 20 63 needs 10s 90 needs 240s 20 60 Sampling flow 0.6L min 20 Pressure range 01.0Mpa The use of temperature 20 60 Environmental humidity 0 100 RH Storage temperature 20 80 Charging time 4 hours The whole machine size 250 150 300mm3 The weight of The machine 3.5kg
Supplier: Engineering Items
Supplier: PCB high-precision instruments and equipment like UV laser cutting machine PP(prepreg) cutting machine TDR impedance tester ionic contamination tester X- ray inspesction machine, hole checker 2D image measuring instrument
Specification - Spactral Range: 400nm to 1700nm - Color Contrast Temperature: 3000K to 5200K - Area of Uniform Illumination: 42mm x 25mm at >200mm working distance - Uniformity of Illumination: better than 98% - Short Term Light Instability: