Model Number: UIYBPF6565A
Pass Band:1000~1300MHz
Bandwidth:10MHz
Insertion loss:2.0 dB
VSWR:1.5
Rejection: 20 dB@F0�±25MHz
Power:50W
Connector Type: N SMA
Temperature: -40~+85â??
Dimension:65*65*37 mm
UHF Band Pass Filter
Frequency range 130-3000MHz, from 1MHz to full bandwidth.
Military, space and commercial applications.
Low insertion loss, high isolation, high power handling.
Custom design available upon request.
Supplier: Engineering components for automotive, electrical, construction, transmission tower projects , rail road components hardware like different types of washers, circlips & retaining rings, clips , clamps ,hose clamp , spring band clamps ,metal pressed parts, wire form parts.
Services: Manufacturing & sourcing agents
Supplier: Solvent distillation plant , ethanol distillation plant , etp, water treatment plant , effluent treatment plant, evaporator , dryer, zld plant, lab equipment supplier, lab chemical supplier, industrial equipment , storage tank , bulk tank, petrochemical plant, ethyl acetate distillation plant, supplier of chemicals, reactor , pressure vessel , instruments, plc panel ,dcs panel, mcc panel , steam boiler, agitator tank, mixing tank, blending tank, bottling plant , vodka plant , ena distillation plant , fermentation plant , cooking plant, cpu plant, dg set, dpr report. etc, industrial dryer, industrial storage tanks, lab equipment, bio cng plant, biogas plant, bioreactor, sludge settling tank, wash settling tanks, pre fermenters, culture vessel, blender, blending tank, agitator, mixing tank, shell and tube heat exchanger, reboiler, reactor, mcc electrical panel, pressure vessel, evaporator, industrial dryer, beer plant, brewery plant, ethanol distillery , grain alcohol distiller plant
SANDI SERIES charging module is for electric vehicle charging station. With single-phase non neutral conductor AC input, it has the advantages of high efficiency, high power density and low harmonic. Functional details 1. Hot plug Plug technology is applied to the charging module to provide convenience for installation and maintenance. The access of the charging module to the system shall not disturb the output voltage of the system. 2. Advanced current sharing technology Under constant voltage working mode, the charging modules can share current automatically within 10S, with degree of unbalance less than �±0.5A. 3. Control of input limited power Refer to Fig. 1-10 for the relation between the output power and input voltage of the charging module. When the input voltage is within 360 Vac ~ 450 Vac (return difference is less than 5V), the module can output the maximum power of 20 KW; when the input voltage is within 260 Vac ~ 320 Vac, the module can still work normally under limited power mode. 4. Control of output constant power When there is a rated input voltage, the output power of the module is 20 KW. Refer to Fig. 11 for the relation between the output voltage and the output current of the module. The SD75050 module uses two operating modes with output voltage ranges of 50 to 750V. The module only selects the operating mode based on the value of the received demand voltage, and does not select the operating mode based on the actual output voltage. 5. Temperature limited power 6. Regulation of output current limiting point 8. Regulation of output voltage The output voltage of the module can be regulated constantly through the external monitoring module, with regulation range of 50Vdc ~ 750Vdc and minimum regulation step of 0.1 Vdc. 9. Fan control The built-in processor of the module can regulate the speed of the fan according to the internal temperature and output current of the module. 10. Protection of input overvoltage/ voltage shortage 11. Output overvoltage protection The overvoltage protection point is 260Vdc ~770Vdc (�±10 Vdc). Default is 778Vdc.The module can be started after manual intervention upon overvoltage protection. 12. Over-temperature protection The environmental over-temperature protection point is 80�°C. When the DC panel has a temperature over 100�°C, the module will stop working; when the DC panel has a temperature below 90�°C, the module will automatically work again. 13. Protection of internal bus fault When the internal bus voltage of the module is beyond the overvoltage/ voltage shortage protection point, the module will be powered off automatically. At this time, there is no output from the module and the fault indicator light is on. 14. Short circuit protection In case of short circuit of the module, it will be subjected to protective shutdown and the red indicator light of the panel is on, and this condition will be transmitted to the monitor of the "module fault".
Model Number: UIYBPF12073A980T1260SF Pass Band: 980~1260MHz Insertion Loss: 0.8dB Ripple: 0.5dB VSWR: 1.3 Rejection: 20dB DC~950MHz 20dB 1290~3000MHz Power:20W Connector Type: SMA-Female Temperature: 40 85 C Dimension: 120 73 36mm
Application :- The XLPE (Cross Link Poly Ethylene) Power Cables are used under ground as well as over head transmission of power in power plants, industries, projects and all other electrical installations. Features :- Manufactured from bright annealed 99.97% pure bare copper & aluminum conductors. These cables are insulated with XLPE compound. Taped/Extruded inner sheath. Round steel wire / flat galvanised steel grip armoured. The outer sheaths can be PVC, HR PVC, FRLS or FR depending upon the application and requirement. Technical Advantage of XLPE Insulation :- Higher current rating, higher short circuit rating (approx 1.2 times that of PVC), thermosetting in nature, higher insulation resistance (1000 times more than PVC cables), higher moisture resistance, better resistance to surge currents, low dielectric losses, better resistance to chemicals and corrosion, longer service life. Comparatively higher cable operating temperature 90�°C and short circuit temperature 250�°C. Technical Data :- Working Voltage : Up to 1100 V Temperature Range : -15�°C to +90�°C Power Cable Sizes : 1.50 Sq. mm to 400.00 Sq. mm in 2, 3, 3 Copper Control Cable Sizes : 1.50 Sq. mm, 2.50 Sq. mm up to 24 cores. Color Codes : 2 Core Cables - Red, Black 3 Core Cables - Red, Yellow & Blue 3 Core Cables - Red, Yellow, Blue & Black (for Neutral) 4 Core Cables - Red, Yellow, Blue & Black 5 Core Cables - Red, Yellow, Blue, Black & Grey 6 Core Cables & above - Adjacent cores are blue for reference and yellow for direction in each lay Black outer sheath Specification : IS:7098 (Part-1) Packing : 500 / 1000 meters on drums
Application :- The Power Cables are used under ground as well as over head transmission of power in power plants, industries, projects and all other electrical installations. Features :- Manufactured from bright annealed 99.97% pure bare copper & aluminum conductors. These cables are insulated with PVC compound. Taped/Extruded inner sheath. Round steel wire / flat galvanised steel grip armoured. The inner & outer sheaths can be PVC, HR PVC, FRLS, HR-FRLS or FR depending upon the application and requirement. Technical Data :- Working Voltage : Up to 1100 V Temperature Range : -15�°C to +70�°C or +85�°C in HR PVC Power Cable Sizes : 1.50 Sq. mm to 400.00 Sq. mm in 2, 3, 3 & 4 core. Copper Control Cable Sizes : 1.50 Sq. mm, 2.50 Sq. mm up to 24 cores. Color Codes : 2 Core Cables - Red, Black 3 Core Cables - Red, Yellow & Blue 3 Core Cables - Red, Yellow, Blue & Black (for Neutral) 4 Core Cables - Red, Yellow, Blue & Black 5 Core Cables - Red, Yellow, Blue, Black & Grey 6 Core Cables & above - Adjacent cores are blue for reference and yellow for direction in each lay Black outer sheath Specification : IS:1554 (Part-1) Packing : 500 / 1000 meters on drums
Model Number: UIYBPF13587A391T396NF Pass Band: 391~396MHz Insertion Loss:2.0dB Ripple in-band:0.8dB VSWR:1.3 Rejection:40dBDC-386MHz 40dB401~2500MHz Power:50W Connector Type: N Female Temperature: 20 60 C Dimension:135 87 68mm
Model Number: UIYBPF300170A470T477NF Pass Band:470 477MHz Insertion Loss:2.5dB Ripple in-band:2.0dB VSWR:1.3
The special explosion-proof cable is composed of conductor, insulation, high-strength braided explosion-proof reinforcement layer, explosion-proof armor layer and antistatic outer sheath. According to the different needs of customers, the insulation layer is divided into inorganic mineral insulation, rubber insulation and plastic insulation. Under the protection of the explosion-proof reinforced layer and explosion-proof armor, the special explosion-proof cable can withstand the destructive force of 55 kg of TNT explosives within a certain distance. At the same time, the anti-static outer sheath can effectively guide the static electricity generated by the friction between the cable and the non-insulator, prevent the fire, explosion and other safety accidents caused by static electricity in military facilities, and perfectly solve the technical problem that the "cable static bundle" is easy to detonate. The special explosion-proof cable also solves the current national defense combat readiness facilities, such as ammunition depots, hangars, military ports, caverns, military and civilian airports, tunnels, military exercise bases, large-scale power, chemical, coal, subway hazardous chemical wharf and other electrical equipment facilities Safety issues of explosion-proof system or unit power transmission. Inorganic mineral insulated explosion-proof cables also have: low-smoke, halogen-free, flame-retardant, low-toxicity, fire-proof and other combustion characteristics, and have passed the most demanding C, W, Z and BS8491 fire tests in the British BS6387. At the same time, the cable has good flexibility, Features such as strong compression resistance and long manufacturing length. Special explosion-proof cable is suitable for ammunition depots, hangars, military ports, caverns, military and civil airports, tunnels, military exercise bases, large electric power, chemical, coal mine, subway dangerous wharves