Fresenius fx8 dialyzer is a part of FX Series dialyzer. Its a single use dialyzer. Fx8 Dialyzer are based on optimized and redefine handling. There are several high end technologies have been combined to provide the distinctive functional feature of FX dialyzer. The structure of fibre bundle, membrane ,flow port and housing design provide the performance of the dialyzer along with safety and handling. The optimal membrane permeability design gives minimal loss of blood components. It gives homogeneous blood flow inside the dialyzer.
Brand Name : HiMEDIA, TM MEDIA Pack Size : 100g, 500g
I can provide some general information based on the terms used: Asahi: Asahi Intecc Co., Ltd. is a company known for producing medical devices, particularly guidewires and microcatheters for interventional procedures in cardiology and radiology. Sion Blue: The term "Sion Blue" could refer to a specific type or model of guidewire produced by Asahi Intecc. Guidewires are thin, flexible wires used to navigate through blood vessels during various medical procedures.
Guide wires are commonly used in medical procedures, particularly in cardiology and radiology, to guide catheters and other devices through blood vessels or other anatomical structures. The Terumo Radifocus Guide Wire M is likely designed for use in vascular interventions. Here are some general characteristics you might find in Terumo guide wires: Material: Guide wires are typically made of materials such as stainless steel or nitinol. Coating: Some guide wires may have hydrophilic or hydrophobic coatings to enhance their performance during navigation through blood vessels. Tip Design: The tip design may vary based on the intended application, with options like floppy or stiff tips. Diameter and Length: Guide wires come in various diameters and lengths to suit different procedures and anatomies. Radiopaque Markers: Radiopaque markers help visualize the position of the guide wire under fluoroscopy.
the Boston Scientific Promus Elite is a coronary drug-eluting stent system. It is designed for use in patients undergoing percutaneous coronary intervention (PCI) procedures to treat coronary artery disease. Here are some key features and points related to the Boston Scientific Promus Elite coronary stent: Drug-Eluting Stent: The Promus Elite is a drug-eluting stent (DES), meaning it is coated with medication to help prevent the re-narrowing (restenosis) of the treated coronary artery. Drug Coating: The stent typically features a polymer coating containing an anti-proliferative drug. This drug is slowly released over time to inhibit the growth of tissue inside the stent, reducing the risk of restenosis. Cobalt Chromium Alloy: The stent is often made of a cobalt chromium alloy, known for its strength and flexibility. This material allows for a thin stent strut design, which can be beneficial in terms of deliverability and conformability. Delivery System: The stent is delivered to the target area using a catheter-based delivery system. The catheter is guided through the blood vessels to the site of the coronary artery lesion. Radiopaque Markers: Radiopaque markers on the stent aid in proper placement and visualization under X-ray guidance during the procedure.
SUMMARY Bilirubin: This test is based on the coupling of bilirubin with a diazotized dichloroaniline in a strongly acid medium. The colors range from light tan to reddish-brown. Ketone: This test is based on the reaction of acetoacetic acid with sodium nitroprusside in a strongly basic medium. The colors range from beige or buff-pink color for a Negative reading to pink and pink-purple for a Positive reading. Specific Gravity: This test is based on the apparent pKa change of certain pretreated polyelectrolytes in relation to the ionic concentration. In the presence of an indicator, the colors range from dark blue or blue-green in urine of low ionic concentration to green and yellow-green in urine of higher ionic concentration. Blood: This test is based on the pseudoperoxidase action of hemoglobin and erythrocytes which catalyzes the reaction of 3,3, 5, 5-tetramethyl-benzidine and buffered organic peroxide. The resulting colors range from orange to yellow-green and dark green. Very high blood concentration may cause the color development to continue to dark blue. pH: This test is based on the well known double pH indicator method, where bromothymol blue and methyl red give distinguishable colors over the pH range of 5-9. The colors range from red-orange to yellow and yellow-green to blue-green. Protein: This test is based on the protein error-of-indicator principle. At a constant pH, the development of any green color is due to the presence of protein. Colors range from yellow for a �??Negative�?? reaction to yellow-green and green to blue-green for a �??Positive�?? reaction. Urobilinogen: This test is based on a modified Ehrlich reaction in which p-diethylaminobenzaldehyde reacts with urobilinogen in a strongly acid medium. Colors range from light pink to bright magenta. Nitrite: This test depends on the conversion of nitrate to nitrite by the action of Gram-negative bacteria in the urine. The nitrite reacts with p-arsanilic acid to from a diazonium compound in an acid medium. The diazonium compound in turn couples with 1,2,3,4-tetrahydrobenzo(h) quinolin to produce a pink color. Leukocytes: This test is based on the action of esterase present in leukocytes, which catalyzes the hydrolysis of an indoxyl ester derivative. The indoxyl ester liberated reacts with a diazonium salt to produce a beige-pink to purple color. Ascorbic Acid: The composition comprises of a complex chelating agent with a polyvalent metal ion in its higher state and an indicator dye that can reacts with the metal ion in its lower state to produce a color change from blue-green to yellow.
Uncut Sheet Toxoplasma Gondii IgG/IgM Tri-Lines Rapid Test Specimen :Whold Blood/Serum/Plasma INTENDED USE The One Step TOXO IgG/IgM Test is a rapid chromatographic immunoassay for the qualitative detection of antibodies (IgG and IgM) to Toxoplasma gondii in Whole Blood /Serum / Plasma to aid in the diagnosis of TOXO infection. Toxoplasma gondii is an obligate intracellular protozoan parasite with a worldwide distribution. Serological data indicates that approximately 30% of the population of most industrialized nations is chronically infected with the organism. A variety of serologic tests for antibodies to Toxoplasma gondii have been used as an aid in diagnosis of acute infection and to assess previous exposure to the organism. These tests are the Sabin-Feldman dye test, direct agglutination, indirect hemagglutination, latex agglutination, indirect immunofluorescence, and ELISA. Recently, lateral flow chromatographic immunoassay, such as The Toxo IgM/IgG Rapid Test (Whole Blood/Serum/Plasma) was introduced into the clinic for the serodiagnosis of Toxoplasma gondii infection. One step TOXO IgG/IgM Test is a simple, visual qualitative test that detects TOXO antibodies in human Whole Blood/serum/plasma. The test is based on immunochromatography and can give a result within 15 minutes. Storage and Stability Store as packaged in the sealed pouch at room temperature or refrigerated (4-30â?? or 40-86â??). The test device is stable through the expiration date printed on the sealed pouch. The test must remain in the sealed pouch until use.
Uncut Sheet HCG Urine/Serum Rapid Test SPECIMEN: Whole Blood/ Serum/ Plasma INTENDED USE The One Step TOXO IgG/IgM Test is a rapid chromatographic immunoassay for the qualitative detection of antibodies (IgG and IgM) to Toxoplasma gondii in Whole Blood /Serum / Plasma to aid in the diagnosis of TOXO infection. Toxoplasma gondii is an obligate intracellular protozoan parasite with a worldwide distribution. Serological data indicates that approximately 30% of the population of most industrialized nations is chronically infected with the organism. A variety of serologic tests for antibodies to Toxoplasma gondii have been used as an aid in diagnosis of acute infection and to assess previous exposure to the organism. These tests are the Sabin-Feldman dye test, direct agglutination, indirect hemagglutination, latex agglutination, indirect immunofluorescence, and ELISA. Recently, lateral flow chromatographic immunoassay, such as The Toxo IgM/IgG Rapid Test (Whole Blood/Serum/Plasma) was introduced into the clinic for the serodiagnosis of Toxoplasma gondii infection. One step TOXO IgG/IgM Test is a simple, visual qualitative test that detects TOXO antibodies in human Whole Blood/serum/plasma. The test is based on immunochromatography and can give a result within 15 minutes. Storage and Stability Store as packaged in the sealed pouch at room temperature or refrigerated (4-30â?? or 40-86â??). The test device is stable through the expiration date printed on the sealed pouch. The test must remain in the sealed pouch until use.
1. INTENDED USE FIV Ab + FeLV Ag Combined Rapid Test is a combined cassette to differentially diagnose the presence of Feline Immunodeficiency antibody and Feline Leukemia Virus antigen in cat's blood. Assay Time: 10-15 min Sample: serum, plasma or whole blood 2. PRINCIPLE OF THE ASSAY FIV Ab + FeLV Ag Combined Rapid Test is based on sandwich lateral flow immunochromatographic assay. The test device has two testing windows. Each testing window has an invisible T (test) zone and C (control) zone. When sample is applied into the sample hole on the device, the liquid will laterally flow on the surface of the test strip. If there is enough FIV antibody or FeLV antigen in the sample, a visible T band will appear in the corresponding testing window. The C band should always appear after a sample is applied, indicating a valid result. By this means, the device can accurately indicate the presence of FIV antibody or FeLV antigen in the sample. 3. KIT COMPONENT - 10 foil pouches, each containing a cassette,pipette and desiccant - 10 assay buffer tubes (0.5 mL each) - 10 centrifugal tubes - Product Manual