JYA - X1 / Y1(CD 400VAC) and Y2(CE 300VAC) Safety Standard Recognized Capacitors Specifications
Operating Temperature -25C~ +85C JYA-Y1-and-Y2-AC-Safety-Standard-Recognized-Capacitors
Capacitance Range 10pF TO 10000pF
Capacitance Tolerance ±10%, ±20%, +80-20%
Rated Voltage AC 125V, 250V, 300V, 400V
Sub-class of
safety performance CD:X1Y1 CE:X1Y2
Temperature Coefficient 2B(Y5P)±10% 2E(Y5U)+22%~-56% 2F(Y5V)+22%~-82%
Dissipation Factor (tan) 2B: 2.5% max. at 25 and 1 KHz, 1 ±0.2 Vrms.
Insulation Resistance at 20 2E/2F: 2.5% max. at 25 and 1 KHz, 1±0.2 Vrms.
Dielectric Strength 10000M at 500VDC for 1 minute.
1500V AC for 60 seconds. (250V AC)
4000V AC for 60 seconds. (400V AC)
Power Modules are Point of Load (POL) DC-DC converters integrating controller chips, chokes and I/O capacitors into a single power management package for step-down(buck) applications. The low profile and compact size enables significant saving of board space, high efficiency enhances application performance, and design structure allows automated assembly by standard surface mount equipment
AC to DC converter battery charger 150-1000VDC rectifier 120KW power supply Product Introductionï¼? SANDI AC/DC Charger is specially developed for DC chargers. It has high efficiency, high power factor, high power density, high reliability advantage. AC input 3 phase, DC output voltage range from 150 to 1000VDC can be set, compliant with CE safety requirements, EMC standard EN61000-6-3 and EN61000-6-1 Class A, it is an advanced international level charger. Unique function High efficiency over the full load range, full load efficiency greater than 95% Wide output voltage range, 150-1000VDC, suitable for a wide range of Lithium or lead acid battery 5-inch LCD touch screen, easy to operate Flexible application, charging voltage, charging current, charging time, timing charging can be set by LCD screen, easy to operate Main featuresï¼? Powerful protection, overheating, short circuit, overload, overvoltage, undervoltage, etc. Wide input voltage range: 260~ 530Vac, adaptable to various power grid environments Three-phase AC input without neutral wire: Simplifies system design, eliminates the risk of excessive neutral current, and reduces system costs. Dual DSP design, achieve the full digital control, less components means high reliability Wide input voltage range, allows operation in most poor grid conditions Battery anti backflow: effectively protects the battery while ensuring reliable and safe operation of the system Input, output have protective circuit breaker switch Module adopts hot pluggable design, which is convenient for maintenance. RS485 interface (Optional)
Application Use for control and connecting cable on data transmission within building management system, speaker audio system and control measurement. Suitable for use in dry and damp environment. Cable Structure & Features Conductor Material : Tinned copper stranded Insulation : Semi-Rigid PVC Drain Wire : Tinned copper stranded Shielding : Aluminium foil laminated screen Outer Sheath ; PVC Sheath Colour : black or gray Technical Data Standard : UL Style 2464 Approvals : UL apporoved Rated Voltage : 300V Testing Voltage : 1500V Flame Retardant : VW-1 Insulation Resistance : Min 20Mx km Min. Bending Radius : 10 x cable diameter Operating Temp. : -30C / +80C
Application :- These multi core flexible cables are used for wiring in control panels, machines and various electrical installations in dry and damp interiors specially under typical industrial environmental conditions. Features :- Manufactured from bright annealed 99.97% pure bare copper conductors, these cables offer low conductor resistance. These wires are insulated with a special grade PVC compound formulated and manufactured in-house. The tough robust outer PVC jacket protects it from oils, greases and various chemicals and abrasions, thereby giving long life and electrical safety. Technical Data :- Working Voltage : Up to 1100 V Temperature Range : -15�°C to +70�°C Sizes : 0.50 to 4.00 Sq. mm in 2 core to 19 cores & 6.00 to 120.00 Sq. mm in 3 core and 4 core. Color Codes : Black and Grey Outer Sheath 2 Core Cables - Red, Black 3 Core Cables - Red, Black & Green (for Earth) 4 Core Cables - Red, Yellow, Blue & Green (for Earth) 5 Core Cables - Red, Yellow, Blue, Black & Grey Specification : IS:694 Packing : In 90 meter coils, higher sizes in drums.
Capillary cable is composed of a submersible power cable and a continuous stainless steel composite pipe. Diluent chemicals are injected into oil and gas Wells through composite pipes to make heavy oil Wells easier to recover. The injection of descaling chemical agent can effectively remove the oil pipe scaling. Sensors can be connected to collect downhole temperature, pressure, liquid level and other well parameters; The valve can be connected to the downhole safety valve and the wireline packer vent valve, and controlled on and off by surface pressure.
The special explosion-proof cable is composed of conductor, insulation, high-strength braided explosion-proof reinforcement layer, explosion-proof armor layer and antistatic outer sheath. According to the different needs of customers, the insulation layer is divided into inorganic mineral insulation, rubber insulation and plastic insulation. Under the protection of the explosion-proof reinforced layer and explosion-proof armor, the special explosion-proof cable can withstand the destructive force of 55 kg of TNT explosives within a certain distance. At the same time, the anti-static outer sheath can effectively guide the static electricity generated by the friction between the cable and the non-insulator, prevent the fire, explosion and other safety accidents caused by static electricity in military facilities, and perfectly solve the technical problem that the "cable static bundle" is easy to detonate. The special explosion-proof cable also solves the current national defense combat readiness facilities, such as ammunition depots, hangars, military ports, caverns, military and civilian airports, tunnels, military exercise bases, large-scale power, chemical, coal, subway hazardous chemical wharf and other electrical equipment facilities Safety issues of explosion-proof system or unit power transmission. Inorganic mineral insulated explosion-proof cables also have: low-smoke, halogen-free, flame-retardant, low-toxicity, fire-proof and other combustion characteristics, and have passed the most demanding C, W, Z and BS8491 fire tests in the British BS6387. At the same time, the cable has good flexibility, Features such as strong compression resistance and long manufacturing length. Special explosion-proof cable is suitable for ammunition depots, hangars, military ports, caverns, military and civil airports, tunnels, military exercise bases, large electric power, chemical, coal mine, subway dangerous wharves
The cable design conforms to the requirements of national standard GB/T12706-2008 and IEC60502 recommended by international Electrotechnical Commission. The normal operating temperature of the conductor of polyvinyl and XLPE insulated cable is 70â?? and 90â?? ,Xlpe cable not only has excellent electrical performance, high working temperature, large transmission capacity, but also has the advantages of simple structure, small outer diameter, light weight, easy installation and use, and unrestricted laying drop. It is widely used in industrial and mining enterprises and urban power grid.
Flexible fireproof cables are composed of copper stranded wires, mineral compound insulation, and mineral compound sheaths. This kind of cable has non-combustible, smoke-free, non-toxic and fire-resistant characteristics. The structure of the flexible mineral insulated cable adopts a flexible structure and materials that are made of mineral compounds, which make up for the defects of hard structure, flammability, and toxicity. It also has some advantages that other cables cannot have, such as: fire resistance, large current carrying capacity, Impact voltage resistance, mechanical damage resistance, halogen-free, non-toxic, explosion-proof, waterproof, corrosion resistance, long life, safety, overload resistance, high temperature resistance, low cost, etc. Flexible fireproof cables have an important role in protecting lives, materials, and information security. They are used in trunk lines, fire lines, escape rescue systems, such as emergency lighting, fire monitoring, alarm systems, elevator systems, smoke exhaust systems, and control lines, etc. Flexible fireproof fireproof cables used in trunk lines, fire lines, escape and rescue systems, such as emergency lighting, fire monitoring, alarm system, elevator system, smoke exhaust system, and control lines, etc. Flexible fireproof fireproof cables used in Public buildings: high-rise buildings, underground buildings, hotels and restaurants, hospitals, schools, business centers, government affairs centers, department stores, large supermarkets, logistics warehouses, financial institutions such as banks, securities and insurance, post and telecommunications centers, power control rooms, substation rooms, museums, memorials and other historic buildings. Flexible fireproof fireproof cables used in Infrastructure: airport terminals, stations, hub centers, ports, subway systems, Bridges, tunnels. Flexible fireproof fireproof cables used in Industry: coal mining, coal chemical industry, oil field mining, petrochemical industry, oil refinery, metallurgical industry, iron and steel industry, shipbuilding industry, aerospace, electric power industry, pharmaceutical industry, glass industry, paper industry, military system. Flexible fireproof fireproof cables used in Fire prevention, explosion prevention, high temperature places: oil depot and gas station, natural gas transmission and compression station, garden landscape, historic sites, wood structure buildings