Best Original Eltek Rectifier Module 48V Network Communication Telecom Switching Power POWERPACK ELTEK DCS-FP48.
ELTEK MICROPACK DC/DC 120W 241120.400 10V-72V/12V
ELTEK FLATPACK2 DC/DC 1350W Rectifier Module 241115.600 1350W 18-75/24V 1350W 18-75/48V INPUT DATA Voltage range 20 - 75 VDC (shutdown < 16.5VDC) Current (maximum) 70 ADC (85 ADC during boost) Protection Fuse and reversed polarity protection OUTPUT DATA Voltage (default) 26 VDC 53 VDC Voltage (adjustable range) 24 - 28 VDC 48 - 58.5 VDC Power (maximum) @ VIN > 26 VDC / VIN = 18 VDC Power boost 15s / 10min recovery (VIN > 25VDC) 1350 W / 910 W 2000W Current (maximum) Current boost 15s / 10min recovery (VIN > 25VDC) 56 A 84 A 28 A 42 A Static Voltage regulation (0 - 100% load) �±1% �±0.5% Dynamic Voltage regulation �±5.0% for 10-90% or 90-10% load variation, regulation time < 30ms Ripple, 20MHz bandwidth < 200 mVpp Protection Short circuit proof, OR-ing diode, High-temperature protection, Hot plug-in inrush current limiting, Overvoltage Shutdown
ELTEK FLATPACK2 DC/DC 18-75/48V1350W Rectifier Module 241115.602 INPUT DATA Voltage range 20 - 75 VDC (shutdown < 16.5VDC) Current (maximum) 70 ADC (85 ADC during boost) Protection Fuse and reversed polarity protection OUTPUT DATA Voltage (default) 26 VDC 53 VDC Voltage (adjustable range) 24 - 28 VDC 48 - 58.5 VDC Power (maximum) @ VIN > 26 VDC / VIN = 18 VDC Power boost 15s / 10min recovery (VIN > 25VDC) 1350 W / 910 W 2000W Current (maximum) Current boost 15s / 10min recovery (VIN > 25VDC) 56 A 84 A 28 A 42 A Static Voltage regulation (0 - 100% load) �±1% �±0.5% Dynamic Voltage regulation �±5.0% for 10-90% or 90-10% load variation, regulation time < 30ms Ripple, 20MHz bandwidth < 200 mVpp Protection Short circuit proof, OR-ing diode, High-temperature protection, Hot plug-in inrush current limiting, Overvoltage Shutdown
ELTEK TSI Bravo 220V/2.5kVA Inverter MODEL 2500 VA/2000 W 220 VDC/230 VAC Part number 241560.601 DC INPUT DATA Voltage (nominal / range) 220 VDC (170 â?? 300 VDC) Current (at 220 V and 2000 W output) / (maximum) 9.8 A / 14.9 A AC INPUT DATA Voltage (nominal) 208 / 220 / 230 / 240 VAC (line to neutral) Voltage (range) 150 â?? 265 VAC (derating between 150 â?? 185 VAC) Voltage brownout 2000 VA/1600 W @ 150VAC; 150 â?? 185 VAC derating: 120 watts per 10 VAC Power factor >0.99 Frequency synchronization range 47 â?? 53 / 57 â?? 63 Hz OUTPUT DATA Voltage (nominal) 208 / 220 / 230 / 240 VAC (line to neutral) Frequency 50 Hz or 60 Hz based on input frequency (+/-0.03 %) Power (maximum continuous) 2500 W / 3000 VA Power (overload capacity) 150 % for 15 seconds Current 10.87 A (at 230 VAC) THD (resistive load)
Emerson EPS30-4815AF 30A DC power double recitifier module Emerson GERM4815TEM EPMU03 GERM4815T EPS30-4815AF Emerson EPS30-4815AF embedded DC power system 30A 1U DC power double recitifier module Emerson GERM4815TEM EPMU03 GERM4815T Regarding other modules, we can still provide.(Huawei/ZTE/Vertiv/Emerson/Eltek/Eaton/Delta) EBU01 EBU02 EBU01 EBU02 EBU01L EDU01 EDU01Z EDU01L EDU02MC EMU10 EMU10MC ER-SD-01S FSU-2808IM IDU IDU-BRG2 IPLU-1202EM IRM-U061D JYM-IIA JYM-II JYM-S Insulation monitor
Flatpack S Intrepid Series 1U High-Efficiency DC Power System APPLICATIONS The Eltek Flatpack S 1U system is a high-efficiency power solution with an optimal footprint for applications where space is limited both in racks and various cabinet installations. The Flatpack S 1U is a one rack-unit high system that delivers 48V DC power to telecom infrastructure that includes: 4G/LTE, FTTx, distributed antenna systems (DAS), microwave broadband, cable broadband, telephony servers and switches, and fiber-optics. PRODUCT DESCRIPTION The compact size of the system makes it perfect for use in 19" or 23" wide racks and cabinets. Built as a plug-and-play system, the Flatpack S 1U reduces installation time and enables cost-effective deployment.
ELTEK Rectiverter 6 kVA Marine UPS 1ph MB MODEL 6 KVA / 3 KVA Part number CIER0418.002/001 INPUT DATA Voltage range AC 185-275 / 95-140 V Voltage range DC 40-58 V Maximum current AC 29 A Frequency 47-53 / 57-63 Hz Power factor > 0.99 OUTPUT DATA Adjustable range AC 200-240 / 100-127 V Adjustable range DC 43-58 V Max output power AC 6,0 / 3,0 kVA Max output power DC 0,6 / 0,3 kW Power factor 0,8 Frequency 50Hz, 60 Hz OTHER SPECIFICATIONS Manual bypass switch 63 A Dual single phase input A and B feed AC Distribution, 2 pole breaker 12pc 6A C char. Battery breaker, 2 pole 125 A ( Remote trip) Ground fault alarm RCR