Executive standard
GB/T7417-2010 "Railway Signal AX Series Relay"
product structure
The electromagnetic system of the stepless enhanced contact slow release relay is the same as that of the stepless slow release relay (JWXC-H340). The magnetic circuit system of the JWJXC-H125/80 stepless enhanced contact slow release relay adds a copper short-circuit ring to make the slow release time longer.
The contact system consists of two parts: ordinary contacts and enhanced contacts. The structure of ordinary contacts is the same as that of non-polar relays, and the reinforced contacts are specially designed high-power contacts and arc wave devices.
Product Usage
The transmission relay is one of the important equipment in the AC counting code automatic blocking equipment. The DC pulse sent by the electric code transmitter is transformed into an AC pulse by the relay, and then sent to the track circuit.
JCZC2-2000 transmission relay is used in the station.
Features
Heavy spring force relay.
It is necessary to install a shock absorber when in use.
Mechanical properties
Number of contact groups: 2QHJ; 2QH
Identification pin number: 14, 53;
Strengthen the contact gap: not less than 1.5mm;
Ordinary contact gap: not less than 0.8mm;
Strengthen the contact pressure: the front contact is not less than 450mN; the rear contact is not less than 450mN;
Ordinary contact pressure: the front contact is not less than 250mN; the rear contact is not less than 250mN;
The air gap between the iron core and the street iron when the relay is working: not more than 0.20mm.
Strengthen the contact pressure on the transmission rod: not less than 100mN.
Strengthen the joint travel: not less than 0.1mm.
Common travel of common contacts: not less than 0.25mm.
Radial travel distance of street iron: 0.3mm-0.7mm.
Street rail vertical travel: 0.3mm-0.5mm.
Street rail axial travel: 0.05mm-0.15mm.
Deyang Dongfang Yoyik is a professional company dedicated to the production, development, sale of power plant spare parts and accessories. Our company has strict requirements to ensure all our products meet the needs of customers. Through more than 20 years of efforts, the majority of customers have been fully recognized. Look forward to your emails and inquiries. Your satisfaction is our greatest comfort. YOYIK provides multiple types of spare parts and equipments for power plant : #DF-Relay GR-2C-AC230V-DF Globe valve J961Y-64I SWITCH PRESSURE 101NN-EE3-N4-C1A Globe valve J961Y-16P radial piston pump hydraulic PV29 2RID CO2 mechanical seal in pump CM104-45 water pump YCZ65-250B SENSOR, TEMPERATURE WRKK2-221 thermocoupl 1000â?? WRN2-239 twin screw pump HSNS210-54NZ Seal ring Sheathed thermocouple WRNK2-0901T �?5 pumps parts hydraulic 80AY-50X10 vaccum pump 30SPEN TC Sensor TE-204 Two-Color water Level Gauge Accessories SFD-SW32-(ABC) vacuum pump price P-1759 thermocouple voltage WRNKB-446S/TG Vent piping YOT51-20-00 vaccum pump SW-30 ksb pump centrifugal 65-250A burgmann mechanical seal N.D.E L270 mechanical shaft seal BF108-45u pump vacuum 30-WS P-2811 thermocouple type k WREK2-191 vacuum pump compressor P-2412 Thermocouple Cylindrical sensor WRNK2-346 mechanical seal 31 mm 11-SHF11/135-E10-A3 00 11 Resistance Thermometers WREX-001 vacuum pump oil P-1945 thermocouple type k WRN-332NM globe throttle check valve KJC25C-1.6P three screw pump HSNH440-46NZ thermowell WRNK-221Filter Element QTL-6027A.02 LCD Screen of Coal Feeder M402SD07G thermocouple digital WRN-330 Relay GR-2C-AC230V vacuum pump oil P-1753 Servo Moog Model : G771K202A VACCUM CIRCUIT BREAKER ZN63-VS1-2000-40KApt100 thermocouple TE-111 Oring mechanical seal pump 108-45 multistage centrifugal pumps CZ65-200 Position Sensor of Guide Vanve GEFRAN LT-M-0225-Pthermocouple wzpk 230 pt100 WPNKZ-630 thermowell flange TE-105 thermowell flange TE-404 rotary vane vacuum pump F3-20V12A-1C22 magnetic coupling centrifugal pump KSB50-250-007 hydraulic screw pump 3GR25*4-2.0/1.0 Current Transformer LBJ1-900A/10V Displacement sensor (LVDT) DET200Ametering piston pump SY400-YB-22 hand valve J61Y-P55 170V DN25 Platinum-Iridium Wire WREX2-001 Control Concepts Z6206052 Seal Oil Pressure Switch 6SC-KK5-N4-C2A Surface Thermocouple WREK2-230 Valve Z961H-64 DN200 metering piston pump Type K Thermocouple Cartridge WREX-001 O-ring HZB253-640-03-09 part no.:39 HP Back up Pump 2CY-45/9-1A transfer pump oil SDH150-125-400 Platinum Thermocouple Wire TE-403 Relay GR-2C-AC230V DFYL-2022-3-15-ZYR
roduct Usage The transmission relay is one of the important equipment in the AC counting code automatic blocking equipment. The DC pulse sent by the electric code transmitter is transformed into an AC pulse by the transmission relay, and then sent to the track circuit. JCZC1-72 transmission relay is used for automatic blocking interval. Features Heavy spring force relay. Dimensions 165mm 49mm 163mm (length width height) Installation method The relay socket is installed on the combination pear (cabinet) with bolts, and the relay is horizontally inserted into the socket and clamped with a hanging spring. Relay identification pin numbers 13, 53. Applicable environment a) Ambient temperature: -40~+60; b) Relative humidity: not more than 90% (temperature +25C); c) Air pressure: not less than 70kPa (equivalent to an altitude below 3000m); d) Vibration: the vibration frequency is not more than 15Hz, and the amplitude is not more than 0.45mm; e) Working position: horizontal; f) There should be no harmful gas causing explosion hazard around, and good dust-proof measures should be taken. maintenance Daily maintenance and maintenance items are as follows: a) Keep the relay and socket clean; b) Observe whether the relay operation status is normal; c) The relay should be replaced in time for abnormal operating conditions and serious contact burnout. Regular maintenance: In the electrical life and life management cycle of the relay, the maintenance cycle of the stepless relay and the rectifier relay should be five years; The overhaul period of stepless enhanced contact relays, poled relays and biased pole relays should be three years; The overhaul period of stepped reinforced contact relays should be one year. Appearance inspection and performance
product description JWXC-7 type infinite relay is a relay widely used in railway signal technology, called signal relay, and it is an important part of railway signal technology. It plays an important role no matter as the core component of the relay signal system or as the interface component of the electronic or computer signal system. The reliability of the relay action directly affects the reliability and safety of the signal system. Product Usage The JWXC-7 type infinite relay is used as a general purpose and air-proof step-down relay in the signal circuit. Applicable environment The applicable environment of the relay is: a) Ambient temperature: -40~+60; b) Relative humidity: not more than 90% (temperature +25); c) Air pressure: not less than 70kPa (equivalent to below 3000m above sea level); d) Vibration: the vibration frequency is not more than 15Hz, and the amplitude is not more than 0.45mm; e) Working position: horizontal; f) There should be no harmful gas causing explosion hazard around, and good dust-proof measures should be taken. product structure Infinite relay is the typical structure of AX series relay, which is composed of electromagnetic system and contact system. The electromagnetic system includes coils, iron cores, vehicle irons and armatures. The coil is installed horizontally on the iron core, and is divided into a front coil and a back coil. The use of dual coils is to enhance the flexibility and flexibility of the control circuit, which can be controlled by a single coil or a series of double coils according to the circuit needs. The armature is fixed on the blade of the yoke by a butterfly-shaped steel wire, which is flexible in movement. There is a heavy hammer in the transmission part of the Yantie to ensure that the relay armature returns reliably by gravity. The number of weights installed is determined by the structure of the relay contact system, and should be able to ensure the reliable release of the relay. A stop piece is installed at the closed position of the armature and the iron core to ensure the minimum air gap of the magnetic circuit of the relay, prevent the ferromagnetic parts of the magnetic circuit from magnetizing, and ensure that the relay falls reliably. The iron core, vehicle iron and armature of the relay are made of electromagnetic pure iron, which has high magnetic permeability and small remanence.
Product Usage The JZXC-H18 rectifier slow release relay is used as a filament supervisory relay in the electric centralized lighting circuit. The use of dual coils is to enhance the flexibility and flexibility of the control circuit, which can be controlled by a single coil or a series of double coils according to the circuit needs. The armature is fixed on the blade of the armature by the butterfly-shaped steel wire, and it moves flexibly. There is a heavy hammer in the transmission part of the armature to ensure that the relay armature returns reliably by gravity. The number of weights installed is determined by the structure of the relay contact system, and should be able to ensure the reliable release of the relay. A stop piece is installed at the closed position of the armature and the iron core to ensure the minimum air gap of the magnetic circuit of the relay, prevent the ferromagnetic parts of the magnetic circuit from magnetizing, and ensure that the relay falls reliably. The iron core, vehicle iron and armature of the relay are made of electromagnetic pure iron, which has high magnetic permeability and small remanence. Product characteristics Mechanical characteristics Number of contact groups: 4QH; Identification pin number: 13, 53; Contact gap: not less than 1.3mm; Pallet gap: not less than 0.35mm; Contact pressure: the dynamic contact point is not less than 250mN; the dynamic disconnection point is not less than 150mN; Contact uniformity error: not more than 0.20mm. Electrical characteristics
Product Usage The JWXC-2.3 type infinite relay is used as a DC track relay in the signal circuit. Features 1. The relay is a heavy elastic DC electromagnetic relay, which uses the principle of "constant gravity" to force the moving and closing contacts to open when the coil is de-energized. 2. It adopts silver-silver cadmium oxide contact, which has the characteristics of strong anti-adhesion and low contact resistance. 3. The magnetic circuit adopts electromagnetic pure iron material with small residual, and installs the stop piece at the closed position of the armature and the iron core to ensure the minimum air gap of the magnetic circuit, prevent the magnetization of the ferromagnetic parts of the magnetic circuit, and ensure the reliable fall of the relay. 4. The contact system is composed of ordinary contacts, and there are four groups of ordinary contacts for switching on and off. 5.The rated current of the relay is 280mA DC. Applicable environment a) Ambient temperature: -40~+60; b) Relative humidity: not more than 90% (temperature +25); c) Air pressure: not less than 70KPa (equivalent to an altitude below 3000m); d) Vibration: the vibration frequency is not more than 15Hz, and the amplitude is not more than 0.45mm; e) Working position: horizontal; f) There should be no harmful gas causing explosion hazard around, and good dust-proof measures should be taken. product structure Infinite relay is the typical structure of Ax series relay, which is composed of electromagnetic system and contact system. The electromagnetic system includes coil, iron core, choke and armature. The coil is installed horizontally on the iron core, and is divided into a front coil and a back coil. The use of dual coils is to enhance the flexibility and flexibility of the control circuit, which can be controlled by a single coil or a series of double coils according to the circuit needs. The armature is fixed on the blade of the iron by a butterfly-shaped steel wire, which is flexible in movement. There is a heavy hammer in the transmission part of the armature to ensure that the relay armature returns reliably by gravity. The number of weights installed is determined by the structure of the relay contact system, and should be able to ensure the reliable release of the relay. A stop piece is installed at the closed position of the armature and the iron core to ensure the minimum air gap of the magnetic circuit of the relay, prevent the ferromagnetic parts of the magnetic circuit from magnetizing, and ensure that the relay falls reliably. The iron core, choke iron and armature of the relay are made of electromagnetic pure iron, which has high magnetic permeability and small remanence. Installation method
> Waterproof, conforms to IP66 > One relay, 2000 users, standalone > Card type: 125KHz EM card only > Working temperature: -40 oC ~ 60 oC (-40 oF ~ 140 oF) > Pulse mode, toggle mode > Built in LDR for anti tamper > Card block enrolment > Easy for programming by master cards and remote control > Easy for install, 6 wires only
Test-630 is a six phase current output and six phase voltage output protection relay tester with 5.Eight pairs of binary input and four pairs of binary output FEATURES Integration in the host crystal 8.4 inches true color, light weight and easy to carry. Built-in high-speed and high-performance industrial computer embedded operating system, running stable and reliable, also can test by connecting PC. Panel embedded user-friendly buttons, and the panel can also be an external keyboard and mouse. High-precision DAC to 12 Road, simultaneously output to ensure the high precision and good linearity of the waveform. 5Matching electromagnetic compatibility components, can improve on-site anti-electromagnetic interference, protection devices can connect the electromagnetic compatibility to test. Analog output of the front panel, switch the amount of terminal design in the upper cover, all the wiring does not affect the operation of the panels and the test parameters of the surveillance. The latest thermal structure design to ensure the best ventilation. Automatically determine over current, over voltage, overload and short circuit, if the temperature is too high, the anomalies and misuse warning of the data will show up promptly. Using voltage, current amplifier AC / DC sharing, output stage uses a unique ultra-linear amplifier technology, high precision and reliability. six-phase AC output voltage and six-phase AC current. 12 analog ports and other optional auxiliary DC source output (220V/110V). Interface: RJ45 (Ethernet interface), USB interface (software upgrades, reporting transmission), industrial serial interface (GPS or other serial device use). TEST ITEM U/I Test DC Test Impedance Characteristics Power Direction Test I-T Test Differential Relay Harmonic Test Differential Protection Distance Protection Zero Sequence Protection Setting Group Test State Sequence Synchronization Test Special Test Oscillation Test Metering Instrument Hardware Checkout Low Voltage Protection Fault Recurrence
E860-DTU(2020-400SL)A wireless remote synchronization switch is a terminal device that realizes remote transmission of switching signal through LoRa modulation technology. It supports 2 channels of switching input (DI) and 2 channels of control relay output (DO). The core of its function is to realize remote synchronous control without wiring, and is highly easy to use, allowing users to quickly integrate it into their own systems.
Overview The three-phase microcomputer relay control tester has a 4-phase voltage 3 phase current output, which is suitable for various types of relay protection devices. The microcomputer relay control tester uses a high-speed high-performance digital signal processor comparative speed, transmission frequency bandwidth, and software application bifurcation algorithm produces each of the respective high-precision waveforms. Due to the integrated structure, each part is closely coupled, the data transmission distance is short, and the structure is compact. Technical parameter: AC current output Output accuracy Level 0.5 Phase current output (effective value) 0 40A Three merge current output (effective value) 0 120A Phase electric length time allows work value (effective value) 10A Phase current maximum output power 420VA Maximum output power at the maximum output of three 1000VA Working time is allowed when the maximum output of the three mesh is output 10s Frequency range (foundation) 20 1000Hz Harmonic number 1 20 times DC current output Output accuracy Level 0.5 Current output 0 10A / each phase, 0 20A / two superimposed Maximum output load voltage 20V AC voltage output Output accuracy Level 0.5 Phase voltage output (effective value) 0120V Line voltage output (effective value) 0210V Maximum voltage output value 0240V Phase voltage / line voltage output power 80VA /100VA Frequency range (fundamental) 201000Hz Harmonics 1 20 times