Online PH meter is accurate meter for measuring PH value of solution.
measuring range 0-14 PH
Accuracy ±0.05
Communication 4-20mA /RS485
Protection:IP54
working condition:0~60
Application sewage fish farm aquaculture etc.
Service: OEM, ODM
Online PH meter is accurate meter for measuring PH value of solution. measuring range 0-14 PH Accuracy ±0.05 Communicatio 4-20mA /RS485 Protection:IP54 working condition:0~60 Application sewage fish farm aquaculture etc. Service: OEM, ODM
Features: 1.Digital reading (lcd), ip65 2.Iso 4064 class c 3.Plastic body 4.Low pressure loss. Email us
Mini ph meter Model rp01 Measuring range 0.0 - 14.0 ph Resolution 0.1 ph Accuracy 0.1 ph Calibration 2 points Plug fixed electrode Size 150 x 29 x 15 mm 46x43x23cm/100pcs 12kg
Waterproof ph meter with backlight Specifications Range 0.0 to 14.0 ph Resolution: 0.1 ph Accuracy : ±0.01 ph Typical emc deviation ±0.1 ph Calibration: manual, 1 point, Temperature compensation automatic: 0 to 50 Environment: 0 to 50 (32 to 122f); Rh max 95% Battery type 4 x 1.5v alkaline Battery life approx. 200 hours of use Dimensions 152 x 30 x 21 mm (5.9 x 1.2 x 0.8") Weight: 53 g Operation Remove the protective cap. Do not be alarmed if white crystals Appear around the cap. This is normal with ph electrodes and They dissolve when rinsed with water. Turn the meter on sliding the switch on the top. Immerse into solution up to the max immersion level. ?¢ stir gently and wait until the display stabilizes. Readings are automatically compensated for temperature variations. After use, switch off ph meter, use the water clean the electrode and replace the protective cap. Do not use distilled or deionized water for storage purposes. Large fluctuations in readings could be due to lack of calibration, dry electrode or rundown batteries. Calibration Immerse the tester up to the maximum immersion level in ph 6.86 buffer solution Allow the reading to stabilize and using a small screwdriver adjust the calibration trimmer to read 6.9. Calibration is now complete. Always use fresh buffers for calibration. Battery replacement When the meter cannot be switched on or the display fades, pull out the battery compartment and replace all three 1.5v batteries, while paying attention to their polarity. Batteries should only be replaced in a safe area using the battery type specified in this instruction manual.
water meter
pHG-1901 industrial online PH meter is a precision meter for measurement of the PH value of solution. With complete functions, stable performance, simple operation and other advantages, they are optimal instruments for industrial measurement and control of PH value. Various PH electrodes can be used in pHG-1901 industrial online PH meter. Features LCD display, high-performance CPU chip, high-precision AD conversion technology and SMT chip technology, Multi-parameter, temperature compensation, high precision and repeatability US TI chips; 96 x 96 world-class shell; world-famous brands for 90% parts The current output and alarm relay adopt optoelectronic isolating technology, strong interference immunity and the capacity of long-distance transmission. Isolated alarming signal output, discretionary setting of upper and lower thresholds for alarming, and lagged cancellation of alarming. High-performance operational amplifier, low temperature drift; high stability and accuracy. Technical Indexes 1. Measuring range: 0~14.00pH, Resolution:0.01pH 2. Precision:0.05pH,±0.3 3. Stability:â?¤0.05pH/24h 4.Automatic temperature compensation: 0~100(pH) 5.Manual temperature compensation:0~80(pH) 6. Output signal: 4-20mA isolated protection output, dual current output 7. Communication interface:RS485(optional) 8. Control interface: ON/OFF relay output contact 9.Relay load: Maximum 240V 5A; Maximum l l5V 10A 10. Relay delay: Adjustable 11.Current output load:Max.750Ω 12. Insulation resistance:â?¥20M 13. Power supply: AC220V ±22V, 50Hz ±1Hz 14. Overall dimension: 96(length)x96(width)x110(depth)mm;dimension of the hole: 92x92mm 15. Weight: 0.6kg 16. Working condition: ambient temperature:0~60, air relative humidity:â?¤90% Except for the earth magnetic field, there is no interference of other strong magnetic field around. Standard configuration One secondary meter, the mounting sheath of immerged (selection), one PH electrode, three packs of standard Ordering guide: 1. To inform whether the electrode provided is a dual or ternary complex. 2. To inform the length of the electrode cable (default as 5m). 3. To inform the installation type of the electrode: flow-through, immerged, flanged or pipe-based
Water meter Our products according to iso4064 class b or c 1pc in a carton or wooden box
Application Measuring the volume of cold potable water passing through the pipeline. Features Removable element for facilitating installation and maintenance, copper sealed register, long term clear reading, inter-exchangeable parts, magnetic transmission, low driving resistance. Reliable sensitive action, small pressure loss, long working life. Application Measuring the volume of cold potable water passing through the pipeline. Features Removable element for facilitating installation and maintenance, copper sealed register, long term clear reading, inter-exchangeable parts, magnetic transmission, low driving resistance. Reliable sensitive action, small pressure loss, long working life.
Water meter Cold and hot water meter. It varies.