We have designed & develop Powered FRP base
Roof Exhaust Fans as per todays industrial needs
for almost 90% of manufacturing and process
industries to help them in improving the best
working environment.
These fans provide exhaust capacity of 10000 CFM,
which is almost 20 times more effective as
compared with the powerless roof ventilation fan.
Products Motor
(hp) Fan Speed CFM
Powerless 24 N/A N/A 250
Motorized 24 1 1440 8,000
Motorized 32 1.5 960 10,000
The air ventilator is a revolutionary conceptual product which exhausts the hot gases from an enclosed area without using any electric power. Yes absolute zero power consumption. It has no operating cost and gives excellent ventilation performance making the work areas like boiler / furnace / oven sheds, curing and drying areas, casting and molding sheds, workshops, process area utility sheds, dg sheds, compressor houses, power house and packing area, go-downs, etc more cooler and comfortable to work in. The air ventilators are most cost effective substitute to the exhaust fans which continuously gulp the electric power and also have maintenance problems
Humiair offers effective, turnkey solutions with regard to Ventilation for office/factory. With a strong engineering and design Set up and efficient project management, we provide quality Services and support to ensure that you have a reliable and Efficient system commissioned on time. We provide General/forced draft ventilation system Pressurization system Balanced ventilation system Humiair misting
For removing hot air., fumes, smoke, irreating smel from the production area, Driven by wind and did not required electricity 50 no.
Comes in many sizes, used fo exhausting hot air, fumes, bad smel 30" x 30" x 22"
1. Introduction: New Air intelligent controller (KF-800M) can monitor real-time indoor temperature, CO2 concentration. Controller output signal can directly control the startup and speed of ventilator. It can be widely used in residential, commercial and industrial applications, and can effectively improve air quality, create a healthy, comfortable, energy-efficient living and working environment. 2. Buttons function: 1. button: timing parameter setting 2. button: parameter increase 3. button: parameter reduce 4. button: setting working mode for controller, press this button slightly, the controller will be switched circularly between AUTO MANUAL TIMER POWER OFF. 3. Display explanation: Time Indoor temperature CO2 concentration Heating switch mode Operating mode Ventilator status 4. Detailed explanation 1. AUTO (auto mode): high speed: CO2 concentration exceeds the setting concentration value of 300ppm; middle speed: CO2 concentration exceeds the setting concentration value of 100ppm; low speed: CO2 concentration exceeds the setting concentration value; stop: CO2 concentration is below the set concentration value. 2. MANUAL: set the ventilator as OFF(stop)LOW(low speed)MED(middle speed)HIG((high speed))by buttons and , and under this mode, the ventilator will run according to the setting, wonH be affected by CO2 concentration. 3. TIMER (timing mode): run according to set time & speed, can set from Monday to Sunday, 4 periods every day, and 28 periods in total. 4. Automatic mode ¡ìCconcentration value setting when the ventilator starts: under the auto mode, press or button for one second, it will appear CO2 concentration setting value and flicker, then press and buttons to change the number (from 350 ¡ìC 600ppm). Controller will return to normal working condition and save setting parameter automatically if you wonH press any buttons more than 10 seconds during the setting process. 5. Timing parameter setting: press button for 2 seconds to enter parameter setting. First enter šÑ�N’“ã¸šÑ time adjust, press button to switch week, hour and minute, the corresponding parameter will flicker, change the number by and buttons; after finishing adjusting local time, press button to enter the first period hour setting on Monday, press button to switch hour, minute, and ventilator speed, press and buttons to change the number. After finish the setting, press button to enter the second period hour setting on Monday. Repeat above steps to finish all the 28 periods setting. Controller will return to normal working condition and save setting parameter automatically if you wonH press any buttons more than 10 seconds during the setting process. 6. Backlight: CO2 concentration less than 500ppm (green backlight), 500-799ppm (yellow backlight), higher than 800ppm (red backlight). 5. Specification
Product Description high-temperature fans are generally used in Kaji furnace,High-pressure forced ventilation and the transport for meterials ,wind and Non-corrosive,Not spontaneous,Non-explosive,Gluten-free gas. About Product Feature:High efficiency,low noise,easy operation ;Adjustable blades high-temperature fans are generally used in Kaji furnace,High-pressure forced ventilation and the transport for meterials ,wind and Non-corrosive,Not spontaneous,Non-explosive,Gluten-free gas. Zibo Dingxian Mechanical Equipment Co.,Ltd which was founded in 1985, mainly designs and manufactures Centrifugal fans and Axial flow fans which are applied to industrial systems, which is the senior member of China General Machinery Industry Association (CGMA). As one of the main large fan manufacturers in North China, which owns more than 200 employees and the production capacity of 15000 sets one year, we have an advanced Air flow Test Laboratory in our company. We master mature fan designing, testing, manufacturing technology, and can design and manufacture multipurpose fans according to users' requirements. So, we are able to meet users' complex and professional applications.
1. Product Name: HRV Heat Recovery Air Ventilation System 2. Exchanger Type: Counter-flow heat exchanger 3. Airflow: 150m3/h to 800m3/h 4. Supply Filter: G4 as standard, F8 for option 5. Extract Filter: G4 as standard 6. Casing Material: Durable coated sheet steel 7. Motor Type: EC Energy Saving Motor (High Static Pressure) 8. Bypass: Bypass AUTO 9. Defrost: Yes 10. Other function: WIFI/APP supported
â? The energy recovery exchanger is washable PSY material different from aluminum or paper materials on the market, it has high ebergy recovery efficiency â?¡The real test "0"PM 2.5 extremely pure air, european standard H I 3 high efficiency â?¥ 99.97% â?¢It is super thin which thickness=18.7~26cm â?£its volume about 150-50000m3/h and the efficiency varies with the volume, Basically around 87 percent.
The iris damper is an ideal air flow regulator and measuring device for circular ducts, the diaphragm valve ensures a perfect accordance between the diameter indication on the handle and the opening of the valve, in the fully open position the iris damper provides 100% free area with on control mechanism in the airstream allowing easy and effective cleaning of the duct work system. Available in sizes 80-800mm