Providing you the best range of endobronchial tube, spinal needle, endotracheal tube- oral/ nasal
(plain), endotracheal tube(cuffed), laryngeal mask and close suction catheter with isolation valve
with effective & timely delivery
Product Detail:
Minimum Order Quantity 500 Piece
Brand Multi Brand
Packaging Type Individual Packed
Usage/Application Hospital, Clinic
Material Special Non toxic, clear, transparent, thermo
sensitive silicon zed PVC Material.
Disposable Type Disposable
Color White
Usage Hospital,Clinic,Laboratory
Sterility Sterile
Quantity Per Pack 10 pcs
Type:- left Angel FG- 35,37,39,41
Right Angel FG- 37,39,41FEATURES: Robert Shaw tube designed to fit patient's anatomy for thoracic or pulmonary
surgery and single lung long-term ventilation.
â?? Anatomically-correct curvatures facilitate proper placement and intubation.
High volume/ low pressure tracheal cuff has a true barrel shape that minimizes pressure on the tracheal tissue and a uniquely shaped bronchial cuff helps prevent accidental upper lobe occlusion.
Tracheal cuff separates the lung from the environment.
Bronchial cuff separates the lungs from each other.
Colour-coded pilot balloons with lure-lock connector, marked with the name of the lumen (tracheal or bronchial) for
easy identification.
"D" shaped Lumina provide maximum cross sectional area, minimising resistance to gas flows.
Provided with double swivel connections with double caps.
Sterile, individually packed.
Features: Robert Shaw Design | Double lumen tube | Single lung ventilation | Anatomically contoured
Supplier: Surgical instruments, dental instruments, diagnostic instruments - otoscope, ophthalmoscope, ent diagnostic sets, percussion hammater, vaginal speculum, anesthesia instruments - laryngoscope, magil forceps, airways
Buyer: Fiber optic, lamps for laryngoscope, lense wheel for ophthalmoscope
Supplier: Diagnostics, sets, universal, set, otoscope, set, blood, lancets, chest, pieces, stethoscopes, percussion, hammers, anesthesia, inhalers, airways, catheter, introducing, forceps, laryngoscopes, puncture, trocars, abdominal, aspiration, suction, tubes, general, instruments, handles, scalpels, knives, razors, dissecting, sets, operating, scissors, plastic, surgery, scissors, neuro, scissors, tonsil, scissors, nazal, scissors, ligature, scissors, ligature, wire, scissors, episitomy, scissors, umbilical, scissors, dissecting, scissors, uterine, scissors, fistula, scissors, eye, scissors, tenotomy, scissors, dental, scissors, dressing, tissue, forceps, splinter, forceps, haemostatic, forceps, haemostatic, forceps, gall, duct, forceps, hysterectomy, forceps, peritoneal, forceps, bronchus, forceps, towelclamps, sinus, dressing, forceps, sponge, forceps, retractors, applicators
An endobronchial tube is a medical device designed for use in the respiratory system, specifically within the bronchial tubes. These tubes are used in various medical procedures, such as bronchoscopy, endobronchial intubation, and lung surgery. The primary purpose of an endobronchial tube is to maintain an open airway and facilitate the delivery of oxygen or anesthesia to the patient's lungs during surgical or diagnostic procedures. Key features and uses of endobronchial tubes include: Bronchoscopy: Endobronchial tubes are often used in bronchoscopy procedures, allowing physicians to visually examine the bronchial tree and perform diagnostic or therapeutic interventions. Lung Surgery: During certain lung surgeries, endobronchial tubes may be employed to isolate and collapse one lung, providing a clear field of view for the surgeon. Ventilation: Endobronchial tubes can be used for selective lung ventilation. They can be positioned to direct ventilation to a specific lung, allowing the other lung to be collapsed or isolated. Anesthesia: In some cases, endobronchial tubes are used for delivering anesthesia during thoracic surgeries or procedures.
Supplier: Disposable infusion (analgesia) pumps, reinforced endotracheal tube, silicone foley catheter, silicone laryngeal mask airway, disposable LED laryngoscope, heat and moist exchange filter, tracheal tube kit and other disposable anesthesia items
Supplier: Disposable medical anesthesia and breathing products, such as laryngeal mask airway, endotracheal tube, closed suction tube, double lumen endobronchial tube, oxygen mask, nebulizer mask breathing filter, cpap mask, breathing anesthesia circuit, other anesthesia and respiration accessories
Services: Manufacturer, r&d, production and export
Trifanz offers the rich choice of Anesthesia Breathing Circuits to meet your clinical need. Set of circuit include, tubes, straight connectors, Y-connector, elbow connector with luer cap,, watertraps size Adult ID 22mm,Pediatric ID 15mm,Neonate ID 10mm Length 0.5-3 meters,any length customized Tube type Corrugated,Expandable,Smoothbore Optional spare parts Anesthesia mask,Breathing bag,BVF HME filter,catheter mount,extra limb,sampling line,suction tube,airway cannula,etc.
1, Available in both silicon and PVC-based Endotracheal Tube, transparent, soft and smooth. 2, Available both with cuff and without cuff. 3, Endotracheal Tube features softer Murphy eye and less evasive tip to prevent damage to tracheal tissue. 4, Tubing transparency and quality conformance are monitored by x-ray visualization to ensure the highest quality of products to be produced. 5, Endotracheal Tube with Murphy Eye, High Volume, Low Pressure Cuff. 6, A spiral wire is incorporated into the wall of the tube to reduce the risk of collapse or kinking. 7, Nasal surgical incubation only. 8, Flex conform to any patient positions, especially to OPS of decubitus. 9, The preloaded Stylets ensures the tube inserted in the right position conveniently. 10, Packed in blister (Dialysis paper+ film), EO sterilization. 11. OEM & ODM available
Special Feature: Application: Adult, Pediatric Driven mode: Pneumatically driven electronically controlled Mode: Semi-open, Semi-closed or closed system Anesthetic vaporizer: One vaporizer Anesthesia Ventilator: Display: High light LED display Ventilation mode: IPPV and Manual mode Tidal Volume: 50 ~ 1600ml Breath frequency: 1 ~ 90BPM I:E ratio: 4:1 ~ 1:6 Monitor parameter: Tidal volume, breath frequency, MV, Airway pressure Alarm: MV high alarm, MV low alarm, TV high alarm, TV low alarm Main Unit: Circle absorber: Compact circle absorber Bellow: 50 ~ 1600ml Oxygen FLUSH: 25L/min ~ 75L/min Flow meter: O2, N2O two-tube flowmeter O2 tube: 0L/min ~ 10L/min N2O tube: 0L/min ~ 10L/min O2 and N2O linkage device Adjust O2 and N2O in proportion ( keep O2 concentration not lower than 25% ) Gas source pressure: O2: 0.25 ~ 0.65Mpa N2O: 0.25~ 0.65Mpa Gauge: 2 units, one N2O, one O2.
Pressure-Volume and Flow-Volume, displayed waveforms can be cycled instantly with a touch of a button 3.Standard integrated metallic modular respiratory circuit; completely solves the problem of gas sealing under high temperature disinfection, easy to clean and disinfect 4.Power Failure Support Functions: Automatically converts to backup power mode during AC power outages 5.Equipped with electronic pressure differential flow sensor, imported respiratory control valve, stable and reliable, rapid response time 6.High precision five tube flowmeter, fitted with interlocking oxygen-nitrous oxide supply, guarantees oxygen output is never lower than 21% 7.Nonhazardous environmentally friendly frame, precise construction, elegant design, equipped with automated self-checking function during startup and an automatic self-calibrating sensor 8.Alarms: Audible and/or visual alarms for tidal volume, airway pressure, oxygen concentration, asphyxia, power failure, oxygen failure and other alarms, also features a alarm query function 9.Vaporizer: Imported tank components assembled locally; Enflurane, Isoflurane and Sevoflurane (Halothane optional). Also possesses self-compensating functionality 10.Advanced and stable Adjustable Pressure Limiting (APL) valve, suitable for low and ultra low flow anesthesia 11.Equipped with advanced international rotating Na-lime tank, easy-operate, requires only one hand, and uses imported PPSU material and temperature resistant to 134�°C 12. Multi-parameter Patient Monitor: Optional