Introduction
AC transformer ratio tester is an innovative product are mainly applied to change than group test transformer, PT and CT polarity test, test speed, high accuracy.
Technical Indicators
Working power supply
AC220 ±10% 50/60 HZ
Instrument weight
3.8 kg
Instrument dimension
325 mm L 225 mm W 125 mm H
Use of temperature
-10-50
Relative humidity
90% No dew
Functional Characteristics
It has the function of blind measurement, that is, to perform variable ratio and group test when there is no connection between high and low voltage.
Based on the test of conventional transformer, Z-type transformer and PT sample, the polarity test function of CT variable ratio is added, and the application field is wider
Wide range and high accuracy, the variable ratio measurement range can reach 10,000, and the test accuracy can be guaranteed 0.3% when the maximum value is 10,000.
It has perfect protection functions such as reverse connection protection and output short circuit protection.
Introduction AC transformer ratio tester is an innovative product are mainly applied to change than group test transformer, PT and CT polarity test, test speed, high accuracy. Technical Indicators Working power supply AC22050/60 HZ Instrument weight 3.8 kg Instrument dimension 325 mm L 225 mm W 125 mm H Use of temperature -10 50 Relative humidity 90 No dew Functional Characteristics It has the function of blind measurement, that is, to perform variable ratio and group test when there is no connection between high and low voltage. Based on the test of conventional transformer, Z-type transformer and PT sample, the polarity test function of CT variable ratio is added, and the application field is wider Wide range and high accuracy, the variable ratio measurement range can reach 10,000, and the test accuracy can be guaranteed 0.3% when the maximum value is 10,000. It has perfect protection functions such as reverse connection protection and output short circuit protection. AC transformer ratio tester Packaging Content Standard accessories 1 transformer turn ratio tester 1 sets of test lines (red and black each) 1 power cord 1 print user manual 1 copy of certificate and factory test report
Product description The current booster is used on checking current transformer,to be the power source supply once current for current transformer or to be other 50Hz single phase current source device. Technical index Temperature Humidit Capacity: 20kVA Specification Weight: 75Kg Allow long-term work on the rated current Allowable overload 1.5 times,30 minutes of continuous work. Feature This PSLLQ is make up of input Winding(220V), output winding below 100A and CXRZ. Output current indicated on the nameplate is defined the rated current that through winding allow to pass.When CX many circles, the rated current its permitted to pass through will inversely decline. The value which ouput capcity divided by product of output current and each circle voltage was the biggest circle number allowing. The current booster is designed to provide the primary current power supply for the current transformer when verifying the current transformer or as other 50HZ single-phase power equipment. The current booster for transformer verification is suitable for power departments such as power testing, power measurement, and power maintenance. The current booster is developed and produced according to the industry standard of transformer error testing, and is used as a current transformer to verify the primary current of the current transformer. The output current can be customized according to customer requirements. The lifter is equipped with casters for easy on-site movement.
Product Characteristics 1. Applicable to transformers connected in Z type. 2. Two output voltages are optional and applicable to transformer whose zero-load current is relatively high. 3. Have wide testing range and the highest transformation ratio may reach 10000. 4. Automatically calculate tap position. 5. Fast speed which is only 18 seconds for three-phase. 6. Favorable repeatability. 7. Automatically save 99 data at most. 8. Flexible data processing including retrieval print transfer to U-disk delete and upload to PC computer for testing. 9. Have transformer short-circuit protection and interturn short-circuit protection functions. In case of short circuit relevant information will be displayed on the LCD screen in characters. 10. The upper computer could control the whole testing process save data . 11. Struction manual is attached to the tester providing convenience for users. 12. The tester is small and is a little bigger than a piece of A4 paper. 13. The tester is light and its weight is only 6.9kg.
Product description The Transformer short circuit impedance tester comes with an adjustable power output. Regardless of single phase or three phase transformers, only one connection is required, and the instrument can complete the measurement of all winding pairs. The test and connection are simple. Main technical indicators and conditions of use Measurement accuracy voltage, current 0.2 level Power COS 0.1 0.5 grade, COS 0.1 1.0 grade Impedance COS 0.1 0.5 grade COS 0.1: 1.0 grade Voltage measurement range AC 3V 300V Internal power output range voltage 0 250V, current 0 10A Current measurement range AC 0.2A 20A Working temperature 10 50 Working humidity 0 80 Working power supply AC220V 10 50Hz 1Hz Dimensions 360mm 220mm 150mm Weight of the instrument 20Kg Transformer Short circuit Impedance Tester
Overview In the power system factories and enterprises have a large number of electrical equipment. Most of its internal insulation is oil-filled insulation type. Dielectric strength test of insulating oil is a necessary routine test item. In order to adapt to the rapid development of the power industry our company is the first in China to develop a fully automatic oil dielectric strength test system. This series of products according to the latest national standard GB t507-2002 the power industry standard dl429.9-91 and the latest power industry standard DL t846.7-2004 design and manufacture using microcomputer control mechanical and electrical integration of all automation high test accuracy greatly improve the work efficiency but also greatly reduce the labor intensity of the staff. It is agreed that this series of products is the ideal insulation oil voltage test equipment in China. Specification Technical Parameters Power supply voltage AC 220V22V Power frequency 50Hz 2.5Hz Work rate 200W output voltage 0-80kV Booster capacity 1.5kVA Booster speed 2.0 2.5 3.0 3.5kV s adjustable Total voltage distortion 3 Installation dimensions 470 390 420mm3 Weight 40kg Conditions of Use Environment temperature 40 Relative humidity 80 Capacity of the oil cup 200ml Distance between the electrodes 2.5mm
Accurately measures voltage transformation ratio of single phase/3 phase delta or star connected transformers, CTs, PTs, power transformers. Features - Automatic operation. No balancing required - Protection against any wrong connections - True 4 terminal measurement - Testing parameters Test Voltage and Ratio Range is customizable to clients requirements - Available models ATRM-1M and ATRM-1uP (additional cost)
Overview Hand-held transformer turn ratio tester is an innovative product with compact size, hand-held operation, more portable and easy to carry. Technical index Range 0.9 10000 Accuracy
Supplier: Industrial process & control products like multi-function meter, lt current transformers, power quality analyzers, temperature controllers, electrical transducers, power supplies, energy meters, analog & digital panel meters, dc converters, temperature sensors, recorders, temperature and humidity monitor, ultrasonic level transducer, testing & measuring instruments, digital multimeters, ac/dc clamp meters, insulation testers, earth testers, power clamp meters
Services: Export
Supplier: Welding and cutting regulators, welding cutter, mig, tig, saw, rectifier, transformer, hose pipe, cable, electrode holder and head, hand screen
Buyer: Tungsten electrodes, auto darkening welding helmet, tig torch spares