Place of Origin:
China
Brand Name:
OEM
Model Number:
check retractor
Type:
Teeth Whitening
Name:
Cheek retractor
Color:
Transparent or OEM color
Brand:
Hey!White or OEM
Material:
PC
Feature:
Convenient and high effect
Package:
PP bag
Keyword:
cheek retractor
It's used in veterinary equipments. Used for rabbit mouth opening. Available in stocks. All other sergical medical equipments orthopedics , dental equipments are available.
The FUE hair transplant equipment is an automatic motorized punching device to extracts grafts for FUE technique. Variable speed 0 to 3000 RPM Reverse & Forward rotation option. Easy to install and carry Low heat Foot switch Speed Control Punch is durable Quick change for FUE punches system without using auxiliary tool can improve work efficiency greatly. Packing including: 1. Motor: 1pcs 2.Handle Piece: 1pcs 3.FUE Punches: 10pcs 4.Tweezer: 2pcs (straight and curved) 5.Hair Implanter Pen: 3pcs (dia:0.8mm/1.0mm/1.2mm) 6.Silicon block for hair: 1pcs 7.Implantation knife handle and blade : 1 set 8. Foot Pedal: 1pcs Hair transplant operating instructions: Hand piece 1.Can adjust intermediate silvery white part,turn to the upper rotating, head clip mouth open, at this time, put accessory into the gap, and then spin to the right, the gap closed, will clamp tight, then can supply power to work. 2.When turning the handle to the upper middle silver parts, head clip mouth open, at this time cannot turn on the power. 3.Handle part only adjustable intermediate silver part, black and gray part cannot be adjusted. Main operating instructions: 1.All parts are one-on-one interface 2.If use foot switch, must step foot that can work. 3.The power supply of main control button, before they leave the factory has been adjusted, red plate have shown that 220 v voltage, please don't change without permission. If your country voltage is 110 v, you can change it till red plate show 110v. Sterilization method: accessories can be high temperature and high pressure sterilization, for other part,use fumigation or with alcohol disinfection,then pack in one-time sterilization bag seal. Ban soak.
The following is the operation of the product 1, insert the used syinge needle to the destorye mouth. 2.Move the handle down to close the destroyer mouth and cut off the needle 3, move the handle up to open the destroyer mouth, now the needle has been destroyed, 4, move the handle to facilitate needle falling into the container The following is more detail information of our products: 10 units/ctn, 48cm*45cm*19cm, G/w:10kg/ctn
The following is the operation of the product 1, insert the used syinge needle to the destorye mouth. 2.Move the handle down to close the destroyer mouth and cut off the needle 3, move the handle up to open the destroyer mouth, now the needle has been destroyed, 4, move the handle to facilitate needle falling into the container The following is more detail information of our products: 10 units/ctn, 48cm*45cm*19cm, G/w:10kg/ctn
Syphilis Test INTRODUCTION Anti-Syphilis Test is a rapid direct binding test for the visual detection of anti-syphilis antibodies in serum as an aid in the diagnosis of syphilis infection. Test results are read visually without any instrument. It is based on the principle of double antigen sandwich immunoassay for determination of syphilis antibodies in serum. Purified recombinant syphilis antigens are employed to identify anti-Syphilis antibodies specifically. This one step test is very sensitive and only takes about 10 to 20 minutes. Syphilis Test SPECIMEN COLLECTION For serum, collect blood into a container without anticoagulant. Allow the blood to clot and separate the serum from the clot. Use the serum for testing. If the specimen cannot be tested on the day of collection, store the serum specimen in a refrigerator or freezer. Bring the specimens to room temperature before testing. Do not freeze and thaw the specimen repeatedly. Syphilis Test PROCEDURE Strip 1.When you are ready to begin testing, open the sealed pouch by tearing along the notch. Remove the test from the pouch. 2. Immerse the strip into the container with the arrow end pointing towards the container. Do not immerse past the MAX (maximum) line. Take the strip out after 8-10 seconds and lay the strip flat on a clean, dry, onabsorbent surface (e.g., mouth of the serum container). 3.Wait 10-15 minutes and read result. Do not read results after 20 minutes. Cassette 1. Open a pouch containing a cassette, lay the cassette. 2. Using the plastic pipettor provided, draw about 2-3 drops (100mL) the sample into the sample well of the cassette. 3. Read results within 10-15 minutes. Do not read results after 20 minutes. INTERPRETATION OF RESULTS Negative: Only one pink band appears on test region of the Cassette. This indicates that there is no detectable Anti-Syphilis in the serum. Positive: Two pink bands appear on test region of the Cassette. This indicates that the specimen contains detectable amount of Anti-Syphilis. Invalid: If without colored band appears on test region, this is an indication of a possible error in performing the test. The test should be repeated using a new device. Syphilis Test PRECAUTION: 1. Must use fresh specimen and avoid repetitive freezing, the result will be invalid 2. Use it before expiry date. 3.The package of kit should not be opened until it reaches the room temperature if it taken out from the refrigerator. 4 .Old Serum can not be used. If the serum is thick, it can be used only after being separated. Syphilis Test LIMITATIONS The test is for in-vitro diagnostic use only.
Contents Name, Air Chamber for Resuscitation/ Manual Aspirator Sphygmomanometer/ Stethoscope Lamina for Pressig Lingua/ Equipment for opening Mouth/ Tongue Forcepes/ Thermometer/ Plexor/ Flashlight/ Scissor/ Dressing Clamp/ Cervix Fixer/ Rolling plywood/ Adhesive Plaster/ Gauze Bandage/ Cravat/ Compressed Gauze/ Medicinal Gauze Pieces/ Alcohol Cotton/ Iodine Cotton Swabs/ Medicinal Gloves/ Tourniquet/ First aid bag/
The following is advantage of the syringe needle destroyer 1.It is used for processing after using needle . so the product is helpful to protect the environment and useful for hospital,medical organization and government. 2.The product is manual operation ,not electrical,so it not only can save the electric power but also more safety. 3.The cutting edge can be replaced, and it can cutting more than 50,000 times of needles according to the Quality Inspection Center Test Report (ICTR). 4.The materials of products is stainless steel. Which is not rust and looking very beautiful. The following is the operation of the product 1, Insert the used syringe needle to the destroyer mouth. 2.Move the handle down to close the destroyer mouth and cut off the needle 3, Move the handle up to open the destroyer mouth, now the needle has been destroyed, 4,Move the handle to facilitate needle falling into the container The following is more detail information of our products: (CE Cettificated)Min Order QuantitY:3000Units N/W: 0.814KG/UNIT Volume of the container: 350ml Size of the cutter:16.5*8.5*14cm Quantity of the needle hub:900-1000pcs according to the size of the needle hub Samples delivery Time: anytime Products delivery Time: according the quantity you ordered. Payment Terms: T/T Package: 46.5*45*17cm 10box/ctn, G/W:10.8KG/CTN
CPR face shield includes a one-way filter and provides a convenient, easy-to-use barrier while performing CPR. Item NO.: TW8340X Payment: 30% in advance, balance before shipment Product Origin: China Color: transparent white Shipping Port: mainly Xiamen or Shanghai, any port in China CPR Face Shield with heart shape box This is a pocket mouth to mouth CPR products. You can hang on your keyring. It is very compact and convenient. When someone needs CPR, you can find it right away. Product Description CPR Breathing Barrier Keychain Kit The item has one-way valve It is compacted in shape, can be placed into any first aid kit and carried easily. The CPR Face Shield be packed in a heart-shaped case. The CPR Face Shield with instruction for use printed on Advantage 1.widely used in CPR training and AED training courses 2.first aid only CPR one-way valve face shield, latex free in mini pocket on keychain 3.a true one-way valve and mouth-to-mouth barrier 4.artificial resuscitation without the risk of ingesting harmful bacteria 5.one size fits children to adults Size:� only one size How to Use 1.Using the recommended head-tilt or chin-tilt method, establish an open airway 2.Insert the airway tunnel into the patientâ??s mouth 3.Place your fingers beneath the shield 4.Pinch patientâ??s nasal airway closed 5.Form an airtight seal between the barrier shield and the patientâ??s mouth 6.Begin CPR ventilation Our Services Customized label, silk printing on pocket Various colors for plastic pocket Packaging & Shipping Each CPR face shield packed in plastic head-shape case 60pcs/middle box, 360pcs/export carton, carton size 57X33X25cm, 10KGS/carton Sea/air shipment, domestic delivery available Application Field First aid, emergency, medical training lesson
Lug-type specification: 17.5cmx9.5cm, composed of the mask body +nose clip+mask belt . Storage conditions: Packaging stored in relative humidity less than 80%, a cool, dry and ventilated indoor epoxy ethane residues.no corrosive gas . take mask the elastic hanging above the ear respectively, on both sides of the nose clips will aim at the nose, with hand pinched nose clip molding, folding, and then open mask debugging till to plug the nose mouth, this mask is a disposable product, replace one after wearing 4 hours, and discard it after use.