Place of Origin:
China
Brand Name:
OEM
Model Number:
FF01-18
Instrument classification:
Class III, Class I, Class II
Properties:
Medical X-ray Equipments & Accessories
Product name:
hospital x ray cassettes
Name:
X-ray Equipment
Application:
X-ray Room .Radiography Department ~
Certificate:
CE ISO
Function:
Medical Diagnosis
Size:
Customized
Type:
Xray Accessories
Color:
White
Item:
X-ray Equipment
Material:
X-ray Protective Material
DESCRIPTIOn: Titanx100 RADIOGRAPHY RATING: 25-100mA, stations 45kVp to 100 kVp in 15 steps OUTPUT: 8KW RECTIFICATION: Full Wave Rectified TIMER: 0.06 to 5 sec DIGITAL DISPLAY : Digital Display of mAs, kV & mA X-RAY TUBE: XD-3/Imported POWER SUPPLY: 230 Voltage AC, 15 Amps LINE REGULATION: 10% 0.6max PROTECTION: Electronic overload Protection TUBE STAND counter Balance Mobile
DESCRIPTION: Titanx RADIOGRAPHY RATING: 25-100mA, stations 45kVp to 100 kVp in 15 steps OUTPUT : 8KW RECTIFICATION: Full Wave Rectified TIMER: 0.06 to 5 sec DIGITAL DISPLAY: Digital Display of mAs, kV & mA X-RAY TUBE: XD-3/Imported POWER SUPPLY: 230 Voltage AC, 15 Amps LINE REGULATION: 10% 0.6max PROTECTION: Electronic overload Protection TUBE STAND: Floor to Ceiling Column Stand
DESCRIPTION: Titanx100 RADIOGRAPHY RATING: 25-100mA, stations 45kVp to 100 kVp in 15 steps OUTPUT : 8KW RECTIFICATION: Full Wave Rectified TIMER: 0.06 to 5 sec DIGITAL DISPLAY: Digital Display of mAs, kV & mA X-RAY TUBE: XD-3/Imported POWER SUPPLY: 230 Voltage AC, 15 Amps LINE REGULATION: 10% 0.6max PROTECTION: Electronic overload Protection TUBE STAND: Counter Balance Mobile
DESCRIPTION- TITANX 100 RADIOGRAPHY RATING- 25-100mA, stations 45kVp to 100 kVp in 15 steps OUTPUT 8KW RECTIFICATION- Full Wave Rectified TIMER- 0.06 to 5 sec DIGITAL DISPLAY- Digital Display of mAs, kV & mA X-RAY TUBE- XD-3/Imported POWER SUPPLY- 230 Voltage AC, 15 Amps LINE REGULATION- 10% 0.6max PROTECTION- Electronic overload Protection TUBE STAND- Spring Balance
purchase of x ray machine VET1600 for pet hospital Advanced Technology of mordern x rays machines VET1600 Innovative A-Si Flat Panel Detector 1,Mature flat-panel detector ensures excellent image quality and reliable clinical diagnosis. 2,Fast imaging time, high efficiency, directly imaging in computer without film processing. Optimized Human -- Friendly Design 1,Multiple self - protection and fault alarming function, safe and reliable. 2,Automatically save parameters when suddenly power off, no lose of data. 3,Four way floating table, electromagnetic brake ensures accurate positioning. Simple Operation, Sharp Image of purchase of x ray machine VET1600 1,Special veterinary radiography modes, easy to operate and safe use. 2,DICOM 3.0 interface supports concise image processing and work list output. Unique Clinical Experience 1,High quality x-ray monoblock assures more details, less dose. 2,Medical fiberboard table surface, scratch-prevented. z
Supplier: X ray machines, Mammography machines, digital Xray, OPG machines, C Arm, dental Xray, Portable X ray
Services: Manufacturing and export
Buyer: X ray tubes
1. When adding up voltage, total current is less than 2a and total power is 500w; 2. The current and voltage of x-ray tubes are fixed in three groups, they are: X exposure voltag (kvp) 60 65 70 X-ray current (ma) 0.5 0.85 1.10 3. When adding up voltage, total current is less than 2a and total power is 500w 4. Drain current and earth resistance are in accordant with the stipulates in gb9706.1 5. The three groups of voltage (60kv, 65kv, 70kv) are adjustable. 6. Wireless remote control in any angles within 10 meters part form the control box 7. The parameter of x-ray generator (bulb tube head) the parameter of x-ray tubes A focus index: 0.3*0.3mm2 B. The voltage of the-highest-voltage generator: 90kv C. The highest inverse peak voltage: 90kv D. Filament characteristic: vf=5v+0.5v, f=3a E. Target surface obliquity: 12 F. The cooling manner of bulb tube head: oil immersion The parameter of x-ray generator (bulb tube head): A. Focus-skin distance: 200mm B.The thickness of filter-ray film: more than 1.5mmal C.The leakage rate of x-ray: no more than 0.002mgy/h (no. 29.204.3 in gb9706.12 prescript that the leakage rate of x-ray is no more than 0.25mgy/h) D. The manner of limiting beam: using planigraphic device
Detecting such as stone ,sand,teflon,fe,sus ,non-fe,harder material and so on in the food stuff