The test system is mainly for power transformer distribution transformer no-load load characteristics; Dc resistance; Variable ratio group test also can be tested transformer power frequency withstand voltage test. At the same time external pick up ct interface is reserved for capacity increase.
Transformer comprehensive test station measurement part is controlled by single chip microcomputer and testdata such as digital display no-load and short circuit are sampled synchronously by single chip microcomputer avoiding errors caused by manual calculation of voltage ammeter and power meter readings respectively in traditional test methods.
Overview The system is suitable for high-voltage 10KV, 35KV low voltage 400V capacity 5000kVA and the following transformer factory test and voltage 10kV capacity 3150kVA and below the distribution transformer no-load test, load test, variable ratio measurement, DC resistance measurement, power frequency withstand voltage test, sensitive The pressure test is integrated integrally integrated, digitized, reducing mechanical faults and reading errors, improves the accuracy and applicability of the overall test system, making the factory trial easier and faster. Technical parameter High pressure 35K, low pressure 400V capacity 5000kVA or less dry press factory test High pressure 10K, low pressure 400V capacity 5000kva dryer factory test High pressure 10K, low voltage 400V capacity 3150kVA or less oil immersion press factory test Voltage transformer metering range and accuracy Voltage Transformer Range: 100V 3.6kV Voltage transformer gear: 3.6kV, 2kV, 1.2kV, 0.6kV Current transformer accuracy: 0.05% Power frequency withstand voltage test Leak current: 300mA Output voltage: 100kV Function: The system has two operating modes (two ways to lock each other, can only work in an operation) automation, flexible design, high integration, complete function
Salisbury's Self-Testing Voltage Detectors allow testing to be continuous and automatic. An intermittent flash and beep confirms the detector is functioning properly. Self-Testing Voltage Detectors are used to verify live or de-energized conductors. These testers may be used with rubber insulating gloves or hot sticks using the splined universal end fitting. Testers indicate the presence of voltage with an extra bright LED light and a distinctive audible signal. It is recommended that the tester be moved closer to the conductor until a warning is indicated, or it touches the conductor, apparatus, or elbow test point. Each tester requires three C batteries (included). Features & Benefits: Do not assume conductors that have been tested de-energized will stay de-energized. Always install proper grounding devices before working. Failure to do so may result in serious injury or death. Dimensions in. (mm): 11 x 3.5 ( 279.4 x 89 )
Product description Multifunctional transformer test bench is a new generation of calibrating device, faster and more accurate. We dedicately develop it to meet the demand of modern calibration. It is made up of an HGQA-C Transformer Calibrator, a current load case, a special test standard for CT and so on. Inheriting the oringinal the features, it is remarkably improved. With flexible match with more load cases and transformers, it performs excellently in quick test and quick point location during CT test. Technical index Environment Conditions Temperature 5 C~40 C Relative humidity
Test Equipment A340E Automatic Transmission training bench Product introduction Based on the electrically controlled automatic transmission of Toyota A340E, and with the speed-regulating three-phase motor as the power source, the training platform can perform the actual operation of various test
Introduction These test pumps are a fast, safe and simple method for hydrostatic testing, ideally suited to work with the above plugs or on a stand alone basis eg heat exchanger tubes, pipes, pressure vessels, hoses, etc. These test pumps are for oil, water or aggressive medium are complete hydraulic units ready for connection which are provided for generating operating pressure up to 1,500bar. The pressure will be generated by means of a pneumatically operated pump. The pump will be connected to the existing industrial compressed-air ductwork system. Advantages - Standstill of the pump when reaching the set final pressure - No energy consumption in case of long pressure holding times - No dissipated heat during the pressure holding phase - Substitute of leakage by automatic re-delivery through the pump - Regulator to control inlet air supply - High pressure bleed valve and high pressure outlet - Simple air-driven pump - Test in the field or in the shop - Simple installation, operationally reliable, easy to maintain
Accurately measures voltage transformation ratio of single phase/3 phase delta or star connected transformers, CTs, PTs, power transformers. Features - Automatic operation. No balancing required - Protection against any wrong connections - True 4 terminal measurement - Testing parameters Test Voltage and Ratio Range is customizable to clients requirements - Available models ATRM-1M and ATRM-1uP (additional cost)
Overview The transformer integrated test system complies with GB1094, GB / T4776, GB / T5169 and other relevant national standards. With the increase in transmission and electrical power generation and the continuous increase in power grids, the successful transformation of the national city network, the farnet, and the number of online quantities and capacity of power transformers are increasing. Technical parameter: Equipment measurement range and precision Voltage metering range: 50V 500V Voltage metering accuracy: 0.2% Current metering range: 0.1a 5a (can be 0.1A 1A) Current metering accuracy: 0.2%; Power frequency withstand voltage test Leak current: 400mA Input current monitoring instrument Monitoring range: 200A Function: Equipment failure automatic detection function, automatically detect peripherals, such as: the voltage regulator is zero, etc .; Test item: no-load loss measurement, no-load current percentage (automatic conversion to the value of the rated voltage), load loss measurement, the impedance voltage percentage (automatic conversion to the rated current reference temperature) Automatic measurement (voltage ratio measurement, connection group label test), external pressure test (power frequency withstand voltage test), induction pressure test (multiplier multiplier test), insulation resistance measurement, lightning shock test, insulation Oil test (breakdown voltage, flash point, acid value, volume resistivity, moisture, etc.), local discharge test, temperature rise test
These test pumps are a fast, safe and simple method for hydrostatic testing, ideally suited to work with the above plugs or on a stand alone basis eg heat exchanger tubes, pipes, pressure vessels, hoses, etc. These test pumps are for oil, water or aggressive medium are complete hydraulic units ready for connection which are provided for generating operating pressure up to 1,500bar. The pressure will be generated by means of a pneumatically operated pump. The pump will be connected to the existing industrial compressed-air ductwork system. Advantages - Standstill of the pump when reaching the set final pressure - No energy consumption in case of long pressure holding times - No dissipated heat during the pressure holding phase - Substitute of leakage by automatic re-delivery through the pump - Regulator to control inlet air supply - High pressure bleed valve and high pressure outlet - Simple air-driven pump - Test in the field or in the shop - Simple installation, operationally reliable, easy to maintain
Automobile ABS+EBD brake system test bench (I) Product introduction This test bench USES Passat B5 ABS braking system as the main material, and adopts four-channel ABS adjustment circuit, and four wheels are adjusted separately. ABS system can run normally and can simulate the working process of