Send InquiryCHAT NOW
Product Details
Product description
When the voltage of the battery pack or the voltage of a single battery is less than the set voltage lower limit, or the set discharge duration or set discharge capacity has been reached during discharge, the tester will automatically stop discharging and record the discharge Real-time data of all valuable and continuous processes in the process.
Battery charge and discharge tester Technical index
Applicable battery
Lead-acid battery
Model
DC220V
Discharge current
0-100A
recharging current
0-30A
Operating mode
Used independently or with a constant-current module
Control accuracy
Discharge current: â?¤�±1%; battery packâ??s terminal voltage: â?¤ �±0.1%; single battery voltage: â?¤�±0.05%
Communication with the host PC
RS485 interface
Data storage capacity
2Gbit FLASH
SANDI SERIES charging module is for electric vehicle charging station. With single-phase non neutral conductor AC input, it has the advantages of high efficiency, high power density and low harmonic. Functional details 1. Hot plug Plug technology is applied to the charging module to provide convenience for installation and maintenance. The access of the charging module to the system shall not disturb the output voltage of the system. 2. Advanced current sharing technology Under constant voltage working mode, the charging modules can share current automatically within 10S, with degree of unbalance less than �±0.5A. 3. Control of input limited power Refer to Fig. 1-10 for the relation between the output power and input voltage of the charging module. When the input voltage is within 360 Vac ~ 450 Vac (return difference is less than 5V), the module can output the maximum power of 20 KW; when the input voltage is within 260 Vac ~ 320 Vac, the module can still work normally under limited power mode. 4. Control of output constant power When there is a rated input voltage, the output power of the module is 20 KW. Refer to Fig. 11 for the relation between the output voltage and the output current of the module. The SD75050 module uses two operating modes with output voltage ranges of 50 to 750V. The module only selects the operating mode based on the value of the received demand voltage, and does not select the operating mode based on the actual output voltage. 5. Temperature limited power 6. Regulation of output current limiting point 8. Regulation of output voltage The output voltage of the module can be regulated constantly through the external monitoring module, with regulation range of 50Vdc ~ 750Vdc and minimum regulation step of 0.1 Vdc. 9. Fan control The built-in processor of the module can regulate the speed of the fan according to the internal temperature and output current of the module. 10. Protection of input overvoltage/ voltage shortage 11. Output overvoltage protection The overvoltage protection point is 260Vdc ~770Vdc (�±10 Vdc). Default is 778Vdc.The module can be started after manual intervention upon overvoltage protection. 12. Over-temperature protection The environmental over-temperature protection point is 80�°C. When the DC panel has a temperature over 100�°C, the module will stop working; when the DC panel has a temperature below 90�°C, the module will automatically work again. 13. Protection of internal bus fault When the internal bus voltage of the module is beyond the overvoltage/ voltage shortage protection point, the module will be powered off automatically. At this time, there is no output from the module and the fault indicator light is on. 14. Short circuit protection In case of short circuit of the module, it will be subjected to protective shutdown and the red indicator light of the panel is on, and this condition will be transmitted to the monitor of the "module fault".
Energizer E91 AA Model No.: E91 Size: AA Nominal Voltage: 1.5V Nominal IR: 150 to 300millionhms Operating Temp: -18â?? to 55â?? Typical Weight: 23.0 gram Shelf Life: 10 years Energizer E92 AAA Model No.: E92 Size: AAA Nominal Voltage: 1.5V Nominal IR: 150 to 300millionhms Operating Temp: -18â?? to 55â?? Typical Weight: 11.5 gram Shelf Life: 10 years
Supplier: Led bulb, tube light, panel light, decoration light, wall light, steel wires, steel plate, stainless steel plate, twisted wire rods, galvanized wires, wire mesh, site fencing, mosquito mesh, thread rods, rebar, twisted rods, t bar, nuts and bolts, hardware, pvc pipes, upvc pipes, api pipes, melamine, mdf board, plywood, film faced, shuttering, packing, core veneer, face veneer, hdf molded door skin, door filler, tubular particle boards, pvc boards, wpc boards, doors, block board, hard board, gypsum board, canopy, carpet, flooring wooden, bamboo, laminated engineering, tiles, granite tiles, granite blocks, black galaxy, wash basin, water closets, washbasins, ss sinks, faucets, furniture, pvc edge bending, crew, locks, pvc seals, silicone cartridges, shower enclosures, shower door hinges, handles, knobs, brackets, slides, nails, solar panels, flexible solar panels, solar power station, battery, inverters, rechargeable fans, lights, spring, 3ply disposable face mask, oxygen concentrator ,
Services: Buying office, oem, components sourcing, value added services
Buyer: In shell pecan nut, macadamia nut
Supplier: Battery Charge And Discharge Tester, Battery Capacity Tester, Battery Comprehensive Analyzer, Lithium Battery Analyzer, Intelligent Lithium Battery Charger
ModeL24/1548/1548/30110/05110/10220/05220/10 Cell voltage measurement type2V/6V/12V Cell voltage measurement range2V:04V;6V:08V;12V:015V Cell voltage resolution2V/6V:0.001V;12V:0.01V Voltage measurement range of battery string030V060V060V0135V0270V0270V String voltage resolution0.01V0.1V Voltage testing accuracy0.5% Discharge current working range2A150A2A150A2A300A250A2-100A250A2100A Constant current discharge voltage range21V30V42V60V42V60V90140V90140V180270V180270V Discharge PowerMax. 4.5kwMax. 9kwMax. 18kwMax. 7kwMax. 13.5kwMax. 13.5kwMax. 27kw Current testing accuracy1% Battery capacity check range20Ah1500 Ah20Ah1500 Ah20Ah3000 Ah20500Ah201000Ah20500Ah201000Ah Current testing accuracy1% Capacity check testing range extensionOne external load added, the testing capacity range doubled Cell data collection methodwire,wireless(optional) Monitoring current range0300 A Working voltageAC220 Cooling modeRefrigeration by blast Working environment;20%80%RH Storage condition-20;C storage and transport Communication modeRS232 communication Data storage modeSD card Display mode4.7 inch TFT Instrument dimensions(mm)400*243*301430*248*381400*243*301 Weight(Kg)141714 Carry methodPortable type Dimensions : 40*24*30cm Weight : 13kg Packing: as your option
After years of research and development our company has successfully developed a series Battery discharge tester with high intelligence and precision with its proprietary technology. Discharge meter can be in offline mode battery as discharge load Through continuously regulating discharge current constant discharge current at the set value can be realized. When discharging the instrument will automatically stop discharging when the battery terminal voltage or monomer voltage falls to the set lower limit or the set discharge time or the set discharge capacity and record all valuable and continuous real-time process data. Battery discharge meter system the voltage monitoring information of single battery is simple safe and accurate with wireless relay access. Battery discharge meter has a very friendly man-machine interface which can not only complete all kinds of settings and data query under the prompt of menu but also save the process data of discharge in the memory of the equipment transfer to the U disk through the data interface and analyze the data through the special software of the upper computer to generate the required curve and report.
Supplier: Backup Power Supply Emergency Power Supply DC Battery Load Tester AC Resistive Load Bank Solar Controller Inverter Battery Impedance Tester Battery Conductance Tester UPS Uninterruptible Power Supply Battery Jump Starter Battery Regenerator Lead Acid Battery Charger Battery Charge Discharge Tester Wide Range Battery Load Bank Tester DC Ground Fault Locator