The high-voltage electric energy measurement devices of power plants and substations and the electric energy measurement devices of a large number of users are related to the interests of power generation power transmission power supply and multiple parties of users. In order to ensure accurate measurement the inspection must be carried out in accordance with SD109 "Inspection Regulations for Electric Energy Measurement Devices" and DL / T448-2000 "Technical Management Regulations for Electricity Measurement Devices".
TKHG-Q current transformer field calibrator was developed based on high-end testing technology large-scale electronic circuit design and in compliance with relevant national regulations. It solves the problems of on-site verification of current transformer and voltage transformer with high working intensity and tedious operation. At the same time the product has reliable performance and powerful functions.
1. The instrument also has a recursive method to measure the current transformer error which is convenient for the on-site verification of the measurement device.
2. On-site verification of current transformers does not require standard current transformers current risers load boxes voltage control boxes and high-current conductors. It uses extremely simple test wiring and operations to achieve the verification of current transformers greatly reducing the work The intensity and working efficiency are improved which is convenient for the on-site verification of transformers.
3. The instrument has a standard voltage transformer equivalent to the same transformation ratio of the measured current transformer. Its accuracy can reach 0.05 level and the transformation ratio and no-load error of the measured current transformer can be accurately measured. Then combine the test results of impedance and admittance to calculate the error of the transformer.
4. Adopt different frequency power supply test close to power frequency to prevent on-site power frequency electromagnetic radiation and series interference.
5. Wide measuring range can reach 5A / 5A ~ 25000A / 5A or 5A / 1A ~ 6300A / 1A.
The high-voltage electric energy measurement devices of power plants and substations and the electric energy measurement devices of a large number of users are related to the interests of power generation power transmission power supply and multiple parties of users. In order to ensure accurate measurement the inspection must be carried out in accordance with SD109 "Inspection Regulations for Electric Energy Measurement Devices" and DL / T448-2000 "Technical Management Regulations for Electricity Measurement Devices". TKHG-Q current transformer field calibrator was developed based on high-end testing technology large-scale electronic circuit design and in compliance with relevant national regulations. It solves the problems of on-site verification of current transformer and voltage transformer with high working intensity and tedious operation. At the same time the product has reliable performance and powerful functions.
Product description Transformer calibrator is a new automatic instrument. We apply advanced electronic technology in the design. By directly decomposing the error signal, it is able to display the percentage, phase error and orthogonal error statistically. It s quick and energy saving. And it s especially good for live testing due to its cute dimension and light weight. Technical Parameters Working Condition: (1) Temperature: 5 (2) Relative humidity:
HGQY-H voltage transformer field tester based on the traditional differential measurement method uses the voltage transformer load error curve extrapolation method mentioned in the newly issued JJG1021-2007 "Power Transformer" Verification Regulations. Using low-voltage extrapolation technology combined with advanced measurement circuits a single instrument can measure electromagnetic voltage transformers from 6kV to 220kV/3 with an accuracy level of 0.05 which is very suitable for field voltage transformer verification. 1. No need for booster voltage standard load box and voltage regulator on site you can achieve the test of voltage transformer ratio difference and angle difference. A single instrument weighs 12 kg which greatly facilitates on-site use. 2. The test speed of the instrument is fast and the measurement of a single voltage transformer does not exceed 1 minute. 3. The instrument is equipped with a micro printer which can print test data on site. 4. It can store 1000 sets of data and can communicate with PC by RS-232 interface. 5. The equipped data management software can be networked with the power system MIS software. 6. Adopt 10.4-inch large-screen LCD display with humanized operation interface and wiring diagram and simple operation guide are attached to the instrument. 7. The output power is large which can meet the required capacity of 220kV voltage transformer boost.
HGQY-H voltage transformer field tester based on the traditional differential measurement method uses the voltage transformer load error curve extrapolation method mentioned in the newly issued JJG1021-2007 "Power Transformer" Verification Regulations. Using low-voltage extrapolation technology combined with advanced measurement circuits a single instrument can measure electromagnetic voltage transformers from 6kV to 220kV/3 with an accuracy level of 0.05 which is very suitable for field voltage transformer verification. 1. No need for booster voltage standard load box and voltage regulator on site you can achieve the test of voltage transformer ratio difference and angle difference. A single instrument weighs 12 kg which greatly facilitates on-site use. 2. The test speed of the instrument is fast and the measurement of a single voltage transformer does not exceed 1 minute. 3. The instrument is equipped with a micro printer which can print test data on site. 4. It can store 1000 sets of data and can communicate with PC by RS-232 interface. 5. The equipped data management software can be networked with the power system MIS software. 6. Adopt 10.4-inch large-screen LCD display with humanized operation interface and wiring diagram and simple operation guide are attached to the instrument. 7. The output power is large which can meet the required capacity of 220kV voltage transformer boost.
HGQY-H voltage transformer field tester based on the traditional differential measurement method uses the voltage transformer load error curve extrapolation method mentioned in the newly issued JJG1021-2007 "Power Transformer" Verification Regulations. Using low-voltage extrapolation technology combined with advanced measurement circuits a single instrument can measure electromagnetic voltage transformers from 6kV to 220kV/3 with an accuracy level of 0.05 which is very suitable for field voltage transformer verification. 1. No need for booster voltage standard load box and voltage regulator on site you can achieve the test of voltage transformer ratio difference and angle difference. A single instrument weighs 12 kg which greatly facilitates on-site use. 2. The test speed of the instrument is fast and the measurement of a single voltage transformer does not exceed 1 minute. 3. The instrument is equipped with a micro printer which can print test data on site. 4. It can store 1000 sets of data and can communicate with PC by RS-232 interface. 5. The equipped data management software can be networked with the power system MIS software. 6. Adopt 10.4-inch large-screen LCD display with humanized operation interface and wiring diagram and simple operation guide are attached to the instrument. 7. The output power is large which can meet the required capacity of 220kV voltage transformer boost.
Product description The current booster is used on checking current transformer,to be the power source supply once current for current transformer or to be other 50Hz single phase current source device. Technical index Temperature Humidit Capacity: 20kVA Specification Weight: 75Kg Allow long-term work on the rated current Allowable overload 1.5 times,30 minutes of continuous work. Feature This PSLLQ is make up of input Winding(220V), output winding below 100A and CXRZ. Output current indicated on the nameplate is defined the rated current that through winding allow to pass.When CX many circles, the rated current its permitted to pass through will inversely decline. The value which ouput capcity divided by product of output current and each circle voltage was the biggest circle number allowing. The current booster is designed to provide the primary current power supply for the current transformer when verifying the current transformer or as other 50HZ single-phase power equipment. The current booster for transformer verification is suitable for power departments such as power testing, power measurement, and power maintenance. The current booster is developed and produced according to the industry standard of transformer error testing, and is used as a current transformer to verify the primary current of the current transformer. The output current can be customized according to customer requirements. The lifter is equipped with casters for easy on-site movement.
HS Code : 2920909090 Packing : 25kgs/drum, 200kg/Drum ,1000kg/Ton drum Application Dimethyl carbonate is a recently developed friendly green organic chemicals, widely used alternative phosgene the dimethyl sulfate Halothanes larger environmental hazards of chemicals used as carbonation and modulating agent, to meet the current requirements of the cleaning process. This article reviews dimethyl carbonate in pesticide and medicine and intermediates (such as furazolidone intermediate 3 - amino-2 - oral oxazolidinone, sulfonylurea herbicides, carbendazim, carbaryl ring ciprofloxacin intermediate 2,4 - dichloro-5 - fluorobenzoyl acetate, isocyanine) synthesis process green transformation.
Product description Single-phase electric meter field calibrator is suitable to test various types single phase meters on site and can also be used to test alternating current parameters. Feature 1. Current clamp and meter combined together, colorful and touch-screen display; 2. One AAA Li-battery can continuously working 4 hours; 3. Wide voltage, current measurement range, voltage range: 15-300V, current range: 0.05-120A; 4. Display all the measuring parameters in one screen; 5. Current clamp has automatic compensation function, 0.2% class accuracy; 6. Current clamp has automatic calibration function; 7. Integration design of the meter and clamp; 8. 16bit high accuracy AD switch 32 bit ARM processor core. 9. Automatically record and save 999 groups calibrate data; 10. Micro-multifunction optic sampler Technical index 1. Manual/automatic test inductive single phase meters; 2. Manual/automatic test electric single phase meters; 3. Measure virtual value of alternating voltage (15 300Vrms); 4. Measure virtual value of alternating current (50mA 120Arms); 5. Test parameters: active power, phase angle of voltage and current, frequency and etc; 6. Automatic store testing data, and 999 group test results can besaved.
Product description Three Phase Energy Meter Field Calibrator is a precision AC energy meter testing instrument, mainly used to test three phase energy meter error on site and measure various of AC parameters. Technical index Electrical parameters Accuracy class 0.05, 0.1 Resolution 6 TFT 640 480 Electrical parameters - continued Power supply 220V 10%, 50 60Hz Li-polymer battery size mm 110 51 16, nominal output voltage 7.2V, capacity 5000mAh Power line supply U1, UN, 85V-265V 50 60Hz Communication port RS232 Test voltage Range 5-480V Error 0.05% 30V-480V 0.1% 5V-30V Harmonic 2nd-63st