We have more than 30 years of production experience recently launched a new generation of automatic intelligent leak detector.It is a stable and sensitive leak detector. We have fully considered the actual needs of the majority of users.At the same time we apply our rich technology and experience to this product so that users can enjoy excellent performance and price ratio.
The high-tech central microprocessing unit is the core of sf6 gas qualitative leak detector. Its digital signal processing ability can better manage the circuit and process the detection signal. Due to the large number of integrated circuits the number of components in the circuit is reduced by 40% which greatly improves the reliability and efficiency. The microprocessor can monitor the probe and battery voltage at the rate of 4000 times per second. Even the tiniest signal can be captured. It can work stably and reliably in any environment.
The sf6 gas qualitative leak detector has added some convenient functions. The seven-level sensitivity increases the sensitivity by 64 times. The three-color leds indicate the degree of leakage in a wide range in a progressive manner and are also used to display sensitivity levels and battery power.Touch keyboard for all operations. Avant-garde long and thin shape design greatly facilitates users to use and maintain. It is very convenient to use the indicator light in the direct range.
Product Introduction The handheld SF6 gas leak detector is a stable and sensitive leak detector. We have fully considered the actual needs of the majority of users, and at the same time apply our rich technology and experience to this product, allowing users to enjoy an excellent price performance ratio. The high tech central microprocessor unit is the core of the qualitative leak detector for sulfur hexafluoride gas. Its digital signal processing capabilities can better manage circuits and process detection signals. Due to the use of a large number of integrated circuits, the number of components in the circuit is reduced by 40, which greatly improves reliability and efficiency. The microprocessor can monitor the probe and battery voltage at a rate of 4000 times per second. Even the smallest signal can be captured. It can work stably and reliably in any environment. The SF6 gas qualitative leak detector has added some convenient functions. Seven-level sensitivity, the sensitivity is increased by 64 times. The three color LED gradually indicates the degree of leakage in a large range, and is also used to display the sensitivity level and battery power. Touch the keyboard to perform all operations. The avant-garde slender shape design greatly facilitates the user's use and maintenance. It is very convenient to use the indicator light in the direct range.
AR5750B Refrigerant/SF6 Gas Leak Detector Description A gas detector is a device that detects the presence of gases in an area, often as part of a safety system. This type of equipment is used to detect a gas leak and interface with a control system so a process can be automatically shut down. A gas detector can sound an alarm to operators in the area where the leak is occurring, giving them the opportunity to leave. This type of device is important because there are many gases that can be harmful to organic life. Gas detectors can be used to detect combustible, flammable and toxic gases, and oxygen depletion, etc. This type of device is widely used in industry and can be found in locations, such as on oil rigs, to monitor manufacture processes and emerging technologies such as photovoltaic. They may also be used in firefighting. This rechargeable refrigerant gas detector respond to all halogenated refrigerant, but also apply to: A. This was response to all halogenated refrigerant (including chlorine and fluoride). Including but not only limited to below: CFCs e.g. R12, R11, R500, R503 etcâ?¦ HCFCs e.g. R22, R123, R124, R502 etcâ?¦ HFCs e.g. R134a, R404a, R125 etcâ?¦ Also can detect compound gas for example AZ-50, HP62, Mp39, etcâ?¦ B. Detect gas leaks in hospital equipments. C. SF6 gas was detected in high voltage circuit shot cut.. D. Detect halogen gas when gas mixing with, chlorine, fluorine,bromine. E. Detect carbon tetrachloride from the dry cleaning machine. F. Detect the halon gas from the fire extinguisher. AR5750B Refrigerant/SF6 Gas Leak Detector Specifications * Detect itemâ??: All halogen gasâ?? * Sensitivityâ??: Halogen refrigerant gas 3gr / yrâ?? * Response timeâ??: Instantaneousâ?? * Warm up timeâ??: < 6 secondâ?? * Continuous operation timeâ??: 5 hours(slightly vary with operation)â?? * Operation temperatureâ??: 0 to 52 deg C( 0 to 110 deg F) * Power supplyâ??: 2000mAh, 3.7V lithium rechargeable batteryâ??
Supplier: Industrial safety (ppe), height safety, fire detection & protection system, gas detection system and building management system (bms) product.
Sensitivity: better than 1/10th oz per year r12 Response time: 0.1 second Spares supplied: 1 spare sensor , 1 pack filters , 1 check leak shipping Specification: 356 x 75 x 89 mm Battery life: 30 hours normal use
The Notifier NBG-12 Series Pull Station is a fire alarm initiation device that allows manual activation of the fire alarm system. It typically consists of a red or yellow manual-pull handle or lever, which when activated, sends a signal to the fire alarm control panel to initiate an alarm. The NBG-12 series is designed for use in fire alarm systems and is commonly used in commercial, industrial, and residential buildings. The product is known for its durability and reliability, and it meets industry standards for fire alarm systems.
RP-2001 is a UL listed six-zone fire alarm control panel for single and dual hazard deluge and preaction applications, providing fire detection, signaling and protection for commercial, industrial and institutional buildings requiring water-based releasing.! Features & Benefits: 1. Designed for sprinkler standards NFPA 13, 15 and 16. 2. Dual hazard operation. 3. Cross-zone (double-interlock) capability. 4. Six programmable Style B (Class B) IDCs (Initiating Device Circuit). 5. Optional Digital Alarm Communicators
RP-2002 is a UL listed six-zone fire alarm control panel for single and dual hazard agent releasing applications, providing fire detection, signaling and protection for commercial, industrial and institutional buildings requiring agent-based releasing. Features & Benefits: Disable/Enable control per input zone and output zone. Extensive transient protection. Dual hazard operation Meets International Building Code (IBC) seismic requirements
The FK-5-1-12 Clean Agents, also known as NOVEC1230 Fire Suppression Agents, is a highly efficient and reliable hydro-fluorocarbon fire extinguishing solution. This product is designed to quickly and effectively suppress fires in various settings while being non-toxic, environmentally friendly, and safe to use. Model Number: FK-5-1-12 clean agents Product Name: NOVEC1230 Fire Suppression Agents Reliability: High Model NO.: FK-5-1-12 clean agents Application The FK-5-1-12 Clean Agents is suitable for use in various applications, including but not limited to: Commercial buildings Industrial facilities Data centers Telecommunication rooms Museums and art galleries Power generation plants Server rooms Control rooms Storage facilities
Halogen leak detector Widely used in refrigerant, aqua-containers, food-processing, heating, green house, medical equipment