aproximitely description dediceted for RS-S
Switchgear design:
Material - aluminum sheet.
Connection method - welding or twisting.
Varnishing - covered with polyester powder varnish in the basic color RAL 7035 or other colors on request.
Roof
Ventilation - gravity labyrinth.
Bottom - cable channel, flat plate or bottom
Installation of equipment - angles enabling the adjustment of the depth of equipment installation.
Doors - double-sided, separate on each part, opened at an angle of 180 �° with a blockade.
Lock - master key locked with a padlock or system insert.
Hinges - internal stainless.
Mounting - galvanized post clam.
JPF2 fixed type metal-enclosed switchgear assembled from modular elements of SF6 insulated switch-disconnector, SF6 switch-fuse combination or vacuum circuit-breaker, in compliance with IEC 298, IEC 420 standards. It is suitable for switching of load current, and controlling the network. It is widely used in medium voltage public distribution systems, high/low voltage prefabricated substation and ring main units. Ratings Rated voltage (kV) 24 Rated bus bars current (A)630 Rated feeder current (A)630 Rated peak withstand current (kA)50 Rated short-time withstand current 2s (kA)20 Cubicle dimension W375(500, 750)*D900*H1900
JPU1-12 Medium Voltage SF6 ring main unit (SF6 RMU, Abbreviation), with the character of excellence reliability and maintenance free, is suitable for AC 3.6 to 12kV power distribution system with configuration either ring or radiant. Its all live part including LBS, CB, ES and primary busbar are sealed in the tank made of stainless steel and the elbow-shape cable connectors are adopted for the incoming or out-going, that leads to the RMU has less influence from service condition therefore it is suitable for using in the bad ambient condition and relatively restricted space. Its service life is more than 20 years. JPU1-12 is compliance with IEC 694, IEC 60265-1/FDIS, IEC 62271-100, IEC 62271-102, IEC 298 & IEC 420. Ratings Rated voltage (kV): 12 Rated load current (A): 630 Rated fuse current (A): 100 Rated breaking current (kA): 50 Rated peak withstand current (kA) 125 Rated short-time withstand current (kA)25 PFWV (kV): 42/48 BIL (kV): 76/85 Cubicle size (mm): W (various)xH1570XD800 Veneer packing
Supplier: LV, MV switchgear
Supplier: Industrial electricals (lv/mv switchgear, motors, softstarters, drives, plcs), automation, instrumentation, test & measurement products
Buyer: Instrumentation, test & measurement products
Supplier: Lv/mv switchgears, empty metal boxes, universal terminal blocks. surface modular enclosures.
Services:
Buyer:
Supplier: DC battery charger, MV/LV switchgear, AC/DC distribution panels
Supplier: Low voltage & medium voltage switchgear ( type tested ), low voltage & retrofit solution, spare part lv and mv switchgear
Services: Manpower service for testing and commissioning
Buyer: Electrical component
Switchgears LV, MV, HV Compact Substations Switch board Cable Trays
Supplier: Informational and directional lighting, emergency lighting luminairies, emergency lighting kits, addressable emergency lighting sys., transient voltage & lightning protection, LV and MV switchgear, fire and security equipment, cable support systems, handrail lighting