Mar-17-21

CellBios offers Freeze-Thaw Bags which protects high-value bio-pharmaceutical in-process and end products. Made of high grade, gamma-stable ethylene vinyl acetate, this new single layer technology has no binders, agents or adhesives. Freeze-Thaw bags are stable in frozen applications (upto -196 C). Freeze-Thaw bags supplied with necessary validation documents to support your Quality & Regulatory requirements.

APPLICATIONS
Freeze-Thaw Studies
Product Storage & Shipment
Formulation & Fill Finish
In-process Sampling and Archiving
Cell Banking
Other Downstream Studies

BENEFITS
Wide temperature Range (from +40 C to -196 C)
Multiple Freeze-Thaw cycles
No delamination
Low Level Leechable & Extractables
Film retains flexibility while in a frozen state

ADVANTAGES
CellStor Freeze-Thaw Bags are designed for ultra low temperature storage and transport solution for biopharmaceutical industry.
CellStor Freeze-Thaw bags provided with multiple port and connector configuration. Bags can be provided with canisters to hold the bags.
Freeze-Thaw bags can be used between +40 C to as low as -196 C applications.


Recent User Reviews

This user has not received any reviews yet!

Verification Status


 
 
Contact Supplier
Renew

More Items Similiar to: Freeze-Thaw Bioprocess Systems

Sep-11-12
 
Features:
Image Mode: B, 2B, 4B, M, B/M, CDFI, CDE, CCD, PW, CW.
Advanced Technology: 3D image supported.
One key image optimization: various of inner checking types/checking types edition and creation/making superior image by pressing
of doctor according to different checking types.
English guide system: real time notice of operation steps, helping doctor get familiar with the operation of device quickly.
Auto freezing protection of the probe: auto freeze the probe in the presetting time, lengthen the life of the probe.
English report system: record the calculating parameters automatically, output English report directly; make the inspection steps much
more efficient.
Expansion port: Video port, S-Video port, RS-232 port, USB2.0 port, VGA port, DICOM3.0 port
Probe supported
Convex probe, vaginal probe, linear probe, phrased array probe; micro convex probe
Nov-17-17
Supplier From Shenzhen, Guangdong, China
 
Uncut Sheet H. Pylori (H.P)Ab Rapid Test

Package:30sheets/pouch

Specimen:Whole Blood/Specimen/Serum

INTRODUCTION

One Step H. Pylori Ab wb /serum/plasma test is a rapid test for the qualitative detection of antibodies specific to Helicobacter pylori in human serum/plasma and whole blood. In this test kit, the H. pylori antigen â?? colloid gold conjugate and specimen moves along the membrane chromatographically to the test region and forms a visible line as the antigenantibodyantigen gold particle complex forms with high degree of sensitivity and specificity. This one step test only takes about 1015 minutes. Test results are read visually without any instrumentation.

SPECIMEN COLLECTION & PREPARATION

Both whole blood (with or without anticoagulant), serum and plasma specimens can be used with this assay. Simply follow the standard clinical produres to collect whole blood, serum or plasma specimens. If the specimen cannot be tested on the day of collection, store the serum/plasma specimen in a temperature of 28 ºC for up to 72 hours. Stir and bring the specimens to room temperature before testing. Do not freeze whole blood specimens. Do not freeze and thaw the specimen repeatedly. Attention: Specimens and all materials coming in contact with them should be handling and disposed of as if capable of transmitting infection. Avoid contact with skin by wearing gloves and proper laboratory attire.

REAGENTS AND MATERIALS SUPPLIED

1. Test kit

2. Specimen diluents in dropper bottle

3. Plastic dropper to dispense sample
Mar-14-18
Supplier From Shenzhen, Guangdong, China
 
1. The One Step RV IgG/IgM Test can be performed used on Whole Blood /Serum / Plasma.
2. To collect whole blood, serum or plasma specimens following regular clinical laboratory procedures.
3. Testing should be performed immediately after specimen collection. Do not leave the specimens at room temperature for prolonged periods. For long term storage, specimens should be kept below -20â??. Whole blood should be stored at 2-8â?? if the test is to be run within 2 days of collection. Do not freeze whole blood specimens.
4. Bring specimens to room temperature prior to testing. Frozen specimens must be completely thawed and mixed well prior to testing. Specimens should not be frozen and thawed repeatedly.
Test Procedure
Allow the test, specimen, buffer and/or controls to reach room temperature 15-30â?? (59-86â??) prior to testing.
1. Bring the pouch to room temperature before opening it. Remove the test device from the sealed pouch and use it as soon as possible.
2. Place the test device on a clean and level surface.
3. Hold the dropper vertically and transfer 1 drop of specimen (approximately 10μl) to the specimen well(S) of the test device, then add 2 drops of buffer (approximately 80μl) and start the timer. See illustration below.
4. Wait for the colored line(s) to appear. Read results at 15 minutes. Do not interpret the result after 20 minutes.
Interpretation of Results
Positive: Control line and at least one test line appear on the membrane. The appearance of T2 test line indicates the presence of RV specific IgG antibodies. The appearance of T1 test line indicates the presence of RV specific IgM antibodies. And if both T1 and T2 line appear, it indicates that the presence of both RV specific IgG and IgM antibodies. The lower the antibody concentration is, the weaker the result line is.
Negative: One colored line appears in the control region(C). No apparent colored line appear in the test line region.
Invalid: Control line fails to appear. Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for control line failure. Review the procedure and repeat the test with a new test device. If the problem persists, discontinue using the test kit immediately and contact your local distributor.
Nov-16-17
Supplier From Shenzhen, Guangdong, China
 
Syphilis Test INTRODUCTION

Anti-Syphilis Test is a rapid direct binding test for the visual detection of anti-syphilis antibodies
in serum as an aid in the diagnosis of syphilis infection. Test results are read visually without any
instrument. It is based on the principle of double antigen sandwich immunoassay for determination of syphilis antibodies in serum. Purified recombinant syphilis antigens are employed to identify
anti-Syphilis antibodies specifically. This one step test is very sensitive and only takes about 10 to 20 minutes.

Syphilis Test SPECIMEN COLLECTION

For serum, collect blood into a container without anticoagulant. Allow the blood to clot and separate the serum from the clot. Use the serum for testing. If the specimen cannot be tested on the day of collection, store the serum specimen in a refrigerator or freezer. Bring the specimens to room temperature before testing. Do not freeze and thaw the specimen repeatedly.

Syphilis Test PROCEDURE
Strip
1.When you are ready to begin testing, open the sealed pouch by tearing along the notch. Remove the test from the pouch.
2. Immerse the strip into the container with the arrow end pointing towards the container. Do not immerse past the MAX (maximum) line.
Take the strip out after 8-10 seconds and lay the strip flat on a clean, dry, onabsorbent surface (e.g., mouth of the serum container).
3.Wait 10-15 minutes and read result. Do not read results after 20 minutes.
Cassette
1. Open a pouch containing a cassette, lay the cassette.
2. Using the plastic pipettor provided, draw about 2-3 drops (100mL) the sample into the sample well of the cassette.
3. Read results within 10-15 minutes. Do not read results after 20 minutes.

INTERPRETATION OF RESULTS

Negative: Only one pink band appears on test region of the Cassette. This indicates that there is no detectable Anti-Syphilis in the serum.
Positive: Two pink bands appear on test region of the Cassette. This indicates that the specimen contains detectable amount of Anti-Syphilis.
Invalid: If without colored band appears on test region, this is an indication of a possible error in performing the test. The test should be repeated using a new device.

Syphilis Test PRECAUTION:

1. Must use fresh specimen and avoid repetitive freezing, the result will be invalid
2. Use it before expiry date.
3.The package of kit should not be opened until it reaches the room temperature if it taken out from the refrigerator.
4 .Old Serum can not be used. If the serum is thick, it can be used only after being separated.

Syphilis Test LIMITATIONS

The test is for in-vitro diagnostic use only.
Oct-24-24
 
Applicators

Ultrasound
Radio frequency
The attachment itself for skin oxygenation, exfoliation and lifting effect - creating CO2 bubbles. Boubble jet effect
Focus:

Innovative exfoliation of dead cells
Skin oxygenation
Suitable for all skin types
Oct-24-24
 
Infuses proprietary serums while removing dead skin
Massaging ultrasound for smooth textures
Multipolar RF for improved elasticity
Micro-current for increased cellular stimulation
Oxygenates skin during nutrient infusion
Hot or cold handle to open and close pores for improved tolerance
Variable pressure product delivery
Sep-11-07
 
Colone videoscope

Distal end
Outer diameter 13mm
Insertion tube outer diameter less than 13mm
Instrument channel inner diameter 3.2mm
Working length 1300mm/1400mm
Optical system visual field 140 straight inspect
Depth of view 3-100mm
Resolution 440k pixels
Range of tip bending up 180 down 180 right 160 left 160
Display full frame or full frame freeze


Carton. 20 kg
Apr-29-08
 
Toyota tester

The intelligent tester ii is designed to fully utilize the enhanced vehicle on-board diagnosis function such as improvement of data refresh rate (can protocol), enhancement of freeze frame data and active test function and so on.
As an aid in diagnosing electrical and electronic control system, it is capable of monitoring and testing electronic control units (ecus) for powertrain, chassis and body systems and their associated sensorsand actuators.
Easy and fast usb connection will realize tight integration with personal computer (pc) based applications and systems. The intelligent tester ii has an ability of future extension via generic memory card slot and change of the optional unit. The wireless communication with pcs will be possible by using wireless card in the future.
Nov-19-08

Honda Diagnostic System Kit

$445.00
MOQ: Not Specified
 
Honda diagnostic system kit

Description:

This interface module kit works with the oem-honda diagnostic pc software (hds). It can diagnose all honda and acura vehicle systems on models from 1992 to year 2008, including can-bus system.

Functions supported by honda/acura protocols:

Reading and decoding fault codes from control blocks' memory;
Deleting fault codes;
Displays system's current parameters in digital form;
Displays system's current parameters in graphical form;
Combined displaying of data;
Management of executive devices;
Logs keeping - writing and keeping of digital parameters in memory;
Special functions - changing of permissible settings of blocks, programming etc.

Functions supported by obd-ii protocols:

Mode 1 - displays system's current parameters in digital form (up to 8 parameters at once);
Mode 2 - displays parameters of "freeze" frame;
Mode 3 - reading and decoding of fault codes from control block's memory;
Mode 4 - deleting of fault codes (memory clearing);
Mode 5 - displays results of oxygen sensors;
Mode 6 - displays results of changeably controled systems and components;
Mode 7 - displays results of constantly controled systems and components;
Mode 8 - management of executive devices;
Mode 9 - displays car's identification info.

Hardware and software requirements:

Pc or laptop with either windows 2000 professional (sp4 or later) or xp (sp1 or later)
Hard disk drive with at least 400mb of free space
Cd-rom drive (if a high-speed internet connection is not available)
Rs232 port required to connect pc to him (pc version software only)
Monitor capable of displaying in vga mode or above (1024 x 768 recommended)
Internet connection (high-speed connection recommended)

Honda diagnostic system kit includes:

1 x him with obd ii cable
1 x dvd
1 x 3 pin cable
1 x rs232 cable
2 x selftest adapter
1 x storage case




Net weight: 3.5kg