Pulse control, Digital radiography, Auto fluoroscopy
*High frequency high voltage x-ray generator and high precision digital pulse control
technology ensure excellent image with low skin dose.
*Digital radiography function, no more film-screen system, simplify the operate process.
*Maximum optimize the image brightness and definition depend on the kV/mA
auto trace function.
*Electric controlled collimator satisfy multi-angle and multi-directional anatomical display requirements.
Friendly user interface, convenient operate
*Human graphic LCD touch screen system
*Hand controller design support long distance exposure
DESCRIPTIOn: Titanx100 RADIOGRAPHY RATING: 25-100mA, stations 45kVp to 100 kVp in 15 steps OUTPUT: 8KW RECTIFICATION: Full Wave Rectified TIMER: 0.06 to 5 sec DIGITAL DISPLAY : Digital Display of mAs, kV & mA X-RAY TUBE: XD-3/Imported POWER SUPPLY: 230 Voltage AC, 15 Amps LINE REGULATION: 10% 0.6max PROTECTION: Electronic overload Protection TUBE STAND counter Balance Mobile
DESCRIPTION: Titanx RADIOGRAPHY RATING: 25-100mA, stations 45kVp to 100 kVp in 15 steps OUTPUT : 8KW RECTIFICATION: Full Wave Rectified TIMER: 0.06 to 5 sec DIGITAL DISPLAY: Digital Display of mAs, kV & mA X-RAY TUBE: XD-3/Imported POWER SUPPLY: 230 Voltage AC, 15 Amps LINE REGULATION: 10% 0.6max PROTECTION: Electronic overload Protection TUBE STAND: Floor to Ceiling Column Stand
DESCRIPTION: Titanx100 RADIOGRAPHY RATING: 25-100mA, stations 45kVp to 100 kVp in 15 steps OUTPUT : 8KW RECTIFICATION: Full Wave Rectified TIMER: 0.06 to 5 sec DIGITAL DISPLAY: Digital Display of mAs, kV & mA X-RAY TUBE: XD-3/Imported POWER SUPPLY: 230 Voltage AC, 15 Amps LINE REGULATION: 10% 0.6max PROTECTION: Electronic overload Protection TUBE STAND: Counter Balance Mobile
DESCRIPTION- TITANX 100 RADIOGRAPHY RATING- 25-100mA, stations 45kVp to 100 kVp in 15 steps OUTPUT 8KW RECTIFICATION- Full Wave Rectified TIMER- 0.06 to 5 sec DIGITAL DISPLAY- Digital Display of mAs, kV & mA X-RAY TUBE- XD-3/Imported POWER SUPPLY- 230 Voltage AC, 15 Amps LINE REGULATION- 10% 0.6max PROTECTION- Electronic overload Protection TUBE STAND- Spring Balance
Pulse control, Digital radiography, Auto fluoroscopy *High frequency high voltage x-ray generator and high precision digital pulse control technology ensure excellent image with low skin dose. *Digital radiography function, no more film-screen system, simplify the operate process. *Maximum optimize the image brightness and definition depend on the kV/mA auto trace function. *Electric controlled rotated beam limiting device can satisfy multi-angle and multi-directional anatomical display requirements. Friendly operate interface *Human graphic LCD touch screen system *Hand controller design support long distance exposure
Fuel LPG. Fuel Tank Capacity 2.0 L Fuel Consumption : App. 225 g P/H Length : 350 mm Height : 330 mm Width : 150 mm Weight(kg) Empty : 1.5 Kg (Empty)
Technical data: Oxygen flow:0.5-5L/min Oxygen concentration:95.5%-87% Output pressure: 40-70kPa Pressure relief mechanism operational at: 250kPa + 25kPa Operation nose Level
Oxygen Concentrator - 0.5-10L/Min Purityï¼? 96% Compressor Life - 25000hours Sound Level 60dB Screen - LED Segment real-time display Power comsumption - 500VA Net Weight - 23k Gross weight:27kg