Frequency: 50-60Hz
Input voltage: AC 100V/110/115V/120V/220V/230V/240V/380V +-10%
Output voltage: MAX 380V +-2%
Power: Max 1000VA
According to: EN61558
HI-POT test: 4000VAC RMS
Insulation class: B(130C)
Ambient temp.(ta) 40C
Degree of protection IP65 IP67 IP68
110ACV to 12ACV 220-250ACV TO 12ACV US/EUR/AUS three standard products MOQ:100 EA Package: carton
1.We have abtained IEC,VDE,UL,CE,ISO9000 approval .we guarantee quality is the first. 2.waterproof Transformer's Dimension Sheet: (Note:Rated 105VA-1000VA for devices 105VA-1000VA watts or less, GWET-105 means 105VA size ) 3.Waterproof outdoor toroidal Transformer's Spcification: 1).WORKING AND SAFETY PROTEETION Eiectrostatic Shield Magnetic Shield TemperatureProtection OverCurrent Protection 2).INSULATION Insulation resistance test(type test):Pri.~sec. 500V DC 100 MΩMIN. HI-POT TEST(100% test):Pass ourdielectric strength test, without any breakdown Pri.~sec. AC 3.8kV for 5 seconds (leakage current 5mAMAX) 3).TEMPERATURE RISE Ta=25ºCTest by resistance method At rated load PRI.& SEC. WINDINGS'TEMPERATURE RISE 75ºCMAX. 4).MAJOR MEASUREMENT FACILITIES: HI-POT TESTER: CJ2670 INSULATION-RESISTANCE METER: ZC-7 VOL TMETER: T19-V DC-RESISTANCE METER: QJ44 AMPEREMETER: T19/1-A 5). MAIN PARAMETERS: Input Voltage:AC 220V 230v 110v (Define the voltage) Output voltage:AC 12V / 24V (Define the voltage) Power range:105VA-1KVA 6) Waterproof toroidal Transformer's materials: * Annular core: Cold rolling directional silicon steel * Insulation protection: Mylar * Core Insulation: Polyester 7C * Primary/Secondary Winding: Enamelled copper wire * Terminal cannula: PVC canula * Termial uderlay: Polyester 19C * Temperature Protection: Thermal Switch * Pri.Insulation: Polyester 7C * Insulation protection: Mylar * Coating insulation: Polyester 5C * Lead: UL WIRE * Potted resin: Potted resin * Body: PP+GFRP 7)Standard conditions and components: * Transformer should meet "Short-circuit-proof safety isolating transformer (inherently or non-inherently) IEC 61558-2-6:09" * Thermal Switch 17AM 211 120 °C Sensata Technologies or equivalent (UL E15962) * Thermal Fuse A7-5A-F 5A/138 °C Aupo Electronics or equivalent (UL E140847) * Transformer is double insulated (Class II) with Insulation Class B 120°C * Insulation tests 500VDC 100M ohm min and 4kV for 5 seconds at 5mA max leakage current 4.Application: Grewin Toroidal Waterproof Transformer with IEC Garden light LED underwater lamp LED Ground light Outdoor power Supply Humidifier Swimming pool Round Enapsulated Transformer with wire leads ,power range: 25VA-6000VA Waterproof Encapsulated transformer Application: 1. Garden light 2. LED underwater lamp 3.LED Ground light 4.Outdoor power Supply 5.Audio sound field 6.Stage lighting 7.Outdoor lighting 8.Christmas Lights
Basic Info Model NO.: 105VA 150VA 180VA 200VA 250VA 300VA 350VA 400VA Usage: LED Underwater Lamp, LED Ground Light Frequency Characteristics: Low Frequency Shape of Core: Ring Brand: Grewin Toroidal Transformer 100% Copper Wire Made: Toroidal Style ABS Fire Material: Plastic Cover High Performance Insulation: Epoxy Resin Anti-Corrosion: Waterproof Performance Outdoor Waterproof Transformer with Plug: Highly Energy Efficient Water-Safe Making IP Rating: IP64 IP66 IP67 Rating for Outdoor Use Application 1: LED Ground Light, Outdoor Power Supply Application 2: Humidifier, Swimming Pool, Garden Light Short-Circuit-Proof Safety: Isolating Transformer Primary/Secondary Winding: Enamelled Copper Wire Trademark: Grewin outdoor waterproof toroidal transformer Transport Package: Export Standard Carton or Customize Strong Pallet Specification: CE Origin: China HS Code: 85043190
.Power quality monitoring .Power instrument and meter .Distributed measurement systems .Measurement of current of power supplyequipment below 10KV .Microcomputer protection Character: .Use high permeability silicon steel . Outdoor , water proof IP65,dust proof .Secondary winding employ with high qualityepoxy resin casting in plastic case which is flame retardant, anti-moisture,stable performance .Split core and full sealed ,use sealedwater proof cable as secondary leading wire
Technical parameters Standards IEC60044-1; IEC 61869-2; NTC 2205; GB1208-2006; ANSI C57.13 Accuracy Class 0.5S, 0.5%, 1%, 3% Range of primary rated current 100-1000A Range of Rated load 10VA Rated frequency 50/60Hz Rated secondary current 5A or 1A Rated short-time thermal current 40kA, 1S Rated continuous thermal current 150%I1n Secondary winding power frequency withstand voltage 3kV, 1min Safety Factor Rating (FS)
Model NO.: EI25 Usage: Single-phase Transformer, Rectifier Transformer, Combined Transformer, Power Transformer, Distribution Transformer, Iron Core for Transformer Frequency Characteristics: Low Frequency Shape of Core: Customized Brand: No brand Core Material: CRGO Silicon Steel Core Output Voltage: Customers Requirement Input Voltage: Customers Requirement Winding Material: Copper\Aluminum Place of Origin: Guangdong, China (Mainland) Frequency: 50-60Hz Customized: Yes Advantage: Quick Delivery Price: Negotiable Transport Package: Customization Specification: customized
Supplier: Waterproof outdoor toroidal transformer
Supplier: Ei transformer, waterproof transformer, power transformer, high frequency transformer, toroidal transformer, inductor, power inverter, iron core
SG (B) 10 series Non-encapsulated H-class Dry-type Power Transformers,Dry type Power Transformers,hermetically sealed transformers,dry type transformer Dry Type Transformer Product Description SG (B) 10 series of non-encapsulated H-class dry-type power transformers adopt the special process technology of German (MORA) dry-type transformers to ensure that the products fully meet the requirements such as fire prevention, waterproof ,environmental protection. It is the ideal product for distribution systems and widely used in the subway, shipbuilding, mining, chemical, power companies and personnel-intensive buildings as well as other special requirements of the occasion for safety.