The range of No. 0 spindles: 1-100 cp
The range of No. 1, 2, 3, 4 spindles: 101-2000000 cp
With Rs232C and temperature sensor
Model : RV-2T
Model RV-2T
Measurement Range 1-2000000 mpa.s
Display LCD
Spindles Specification No. 0, 1, 2, 3, 4
Note: The bigger the number of the Spindles, the bigger the measuring value
Rotating Speed of Spindles 0.3 / 0.6 / 0.5 / 3 / 6 / 12 / 30 / 60 rpm
Automatic Switch free selection of proper rotating speed or Spindles number.
Stable Cursor Strip-type cursor fully charged displayed when reading basically stable
Measurement Tolerance ± 2%
Power AC 220V ± 10% 50 Hz ± 10%
Working Condition Temperature 5-35 degree
Relative humidity no more than 80%
Scope Engine oil apparent viscosity analyzer applicable standards: gb / t6538 astm d5293 low dynamic viscosity index of the engine oil, the main test instrument, the use of modern advanced technology, mechanical, optical electronics and computer technology, and temperature measurement, temperature control. Temperature accuracy and stability. Engine oil apparent viscosity analyzer reasonable structure, stable performance, simple operation, is the ideal detection equipment. Features 1, engine oil apparent viscosity analyzer using the lcd screen display, man-machine interface friendly exchanges. 2, the engine oil apparent viscosity analyzer configured automatic diagnosis system, automatic fault prompts. 3, the engine oil apparent viscosity analyzer uses flanders brand speed control system and imported motor drive, to a great extent on the stability of the driving current stable and precise control drive motor speed, more accurate results. 4, the engine oil apparent viscosity analyzer automatically corrects the speed control system configuration system, automatic viscosity correction system, automatic calibration function curve system. 5, engine oil apparent viscosity analyzer smart operating system, the user simply one-button operation, automatic heating equipment, automatic timing, automatic calculation, automatic thermostat, automatic save results automatically print the report. Technical parameters 1, cooling mode: imported compressor refrigeration 2, temperature range: room temperature ~ -35 ± 0.1 ? 3, circular way: imported low temperature cycle pump drive 4, the temperature control: temperature control system microcontroller 5, the drive motor: imported motor 6, display: lcd 7, the correction method: standard oil correction 8 power supply: ac220v ± 10% 50hz
Scope Automatic high-temperature high-shear viscosity meter were measured and the apparent viscosity of the lubricant at high temperature and high shear rates, the test principle is at 150 ? test conditions, under nitrogen (carbon dioxide) pressure, the sample from the capillary viscosity meter flow, and pressure from the flow time of the sample, obtained apparent shear rate capillary viscometer reaches a certain apparent viscosity, with each pool viscometer calibration curve corresponding to the measured pressure of the oil viscosity. Features 1, high-temperature high-shear viscosity automatic analyzer for domestic initiative, the key components used by the us cn accessories to ensure product quality; 2, automatic high-temperature high-shear viscosity meter with digital display of pressure and time, more intuitive controllable; 3, high-temperature high-shear viscosity automatic analyzer using flanders dedicated high shear viscosity calculation software prompts, easy to learn; 4, there is a stopcock automatic high temperature and high shear viscosity of each sample tube detector, in line with the standard requirements; 5, automatic high-temperature high-shear viscosity analyzer configured with ftc circuit protection devices, over-temperature automatically cut off power; Technical parameters 1. Applicable standards: astm d5481 sh / t0703 2, heating: electric heating rods 3, temperature range: room temperature ~ 150 ? 4. Determination of the viscosity range: 0.5-8mpa.S@150c 5, the control pressure range: 3.5kgf / cm2 ~ 35kgf / cm2 6, sample capacity: 10 ml 7, pressure display: digital pressure gauge 8, the time display: digital schedule 9, the result of the calculation: friend’s dedicated calculation software 10, power supply: ac220v 50hz
Scope Automatic high-temperature high-shear viscosity meter were measured and the apparent viscosity of the lubricant at high temperature and high shear rates, the test principle is at 150 ? test conditions, under nitrogen (carbon dioxide) pressure, the sample from the capillary viscosity meter flow, and pressure from the flow time of the sample, obtained apparent shear rate capillary viscometer reaches a certain apparent viscosity, with each pool viscometer calibration curve corresponding to the measured pressure of the oil viscosity. Features 1, high-temperature high-shear viscosity automatic analyzer for domestic initiative, the key components used by the us cn accessories to ensure product quality; 2, automatic high-temperature high-shear viscosity meter with digital display of pressure and time, more intuitive controllable; 3, high-temperature high-shear viscosity automatic analyzer using flanders dedicated high shear viscosity calculation software prompts, easy to learn; 4, there is a stopcock automatic high temperature and high shear viscosity of each sample tube detector, in line with the standard requirements; 5, automatic high-temperature high-shear viscosity analyzer configured with ftc circuit protection devices, over-temperature automatically cut off power; Technical parameters 1. Applicable standards: astm d5481 sh / t0703 2, heating: electric heating rods 3, temperature range: room temperature ~ 150 ? 4. Determination of the viscosity range: 0.5-8mpa.S@150c 5, the control pressure range: 3.5kgf / cm2 ~ 35kgf / cm2 6, sample capacity: 10 ml 7, pressure display: digital pressure gauge 8, the time display: digital schedule 9, the result of the calculation: friend’s dedicated calculation software 10, power supply: ac220v 50hz
Scope Standard: sh / t0123 Sample in 95 ° c, which leads to constant dry air, test 312h, by measuring changes in growth and sedimentation value of the sample value 100 ° c kinematic viscosity. Features 1, extreme pressure lubricant oxidation characteristics analyzer using intelligent temperature controller with a microprocessor, with self-tuning, self-diagnostic function, pid three parameters to adjust the temperature, auxiliary heating automatically turn off, thus high precision temperature control, performance stable and reliable. 2, extreme pressure lubricant oxidation characteristics analyzer with automatic timing device, without manual timing, when the alarm. 3, extreme pressure lubricant oxidation characteristics analyzer using precision flowmeter control systems, flow can be set with the user. 4, extreme pressure lubricant oxidation characteristics analyzer uses an integrated setting, operation and maintenance simple and convenient. Technical parameters 1, temperature range: room temperature ~ 150 ° c, temperature control accuracy: 0.1 °c. 2, temperature control mode: intelligent temperature control thermostat. 3, power supply: ac220v 50hz. 4, the heating method: oil bath. 5, the timing device: automatic timer. 6, the flow control: precision flowmeter.
LAG-S200 Ladle Slag Detection System (Vibration Type) Overview The continuous casting vibration type ladle slag detection device is used to detect the slag content of the ladle nozzle in the steelmaking continuous casting process, so as to improve the cleanliness of the tundish molten steel and obtain the best yield of the ladle molten steel. The device adopts the principle of vibration detection. The LAG-S200 continuous casting ladle slag automatic detection system after many years of research with many scientific research institutes, and fully combined with the actual situation on site. It has a real field application value as a continuous casting ladle slag automatic detection system. The meaning of the system 1. Reduce the amount of tundish slag 2. Improve the purity of molten steel 3. Improve the life of the tundish 4. Reduce sliding nozzle erosion 5. Reduce nozzle blockage 6. Increase the number of continuous pouring furnaces 7. Reduce the amount of residual steel in the ladle when high-quality steel is casting 8. Improve the yield of molten steel 9. Improve the quality of continuous casting billets In order to improve the purity of the molten steel in the tundish, and improve the quality of the casting billet, especially to improve the quality of the billet in the transition section, and reduce the amount of residual steel in the high-quality ladle, and prolong the life of the tundish lining, and increase the number of continuous casting furnaces, necessary to detect and control the slag in the later stage of continuous casting ladle casting. The Working principle of the system The LAG-S200 continuous casting ladle slag automatic monitoring system detects the slag state during the pouring process by receiving the vibration signal of the mechanical operating arm of the ladle nozzle. In the process of molten steel pouring, when molten steel flows through the long nozzle and pours into the tundish, the molten steel impacts the wall of the long nozzle and causes the vibration of the mechanical operating arm used to support the long nozzle. Since the specific gravity of the steelmaking slag is less than half of the specific gravity of the molten steel, it floats on the surface of the molten steel, and the steelmaking slag appears when the molten steel is about to be all poured. At this time, due to the high viscosity and poor fluidity of light steelmaking slag, the impact force of the mixed flow of molten steel and steel slag on the wall of the long nozzle is quite different from that of pure molten steel. The system mainly monitors the ladle slag of the continuous casting by measuring and analyzing the vibration difference of the mechanical operating arm.