Power Bank Emergency Kit with Led Torch Flashlight Battery Power Booster Jumper Starter Capacity: 6000mAh Start output: 200A Peak current: 400A Input: 5V1A CE5 output: 12V USB output: 5V2A
Power Bank Emergency Kit with Led Torch Flashlight Battery Power Booster Jumper Starter Color box size: 237 6cm Weight with package: 650G Product Weight: 460G Capacity 12000mAh Instant current: 600-1200A Peak current: 1200A Input: 18V1A USB output: 5V2.1A
Basic Parameters Dimensions: 201 x 99 x 35 mm Weight: 333g Adapter Input: AC 100 ~ 240 V Output: DC 24V 2.65A Display mode Segment LCD with white backlight + LED in red and green Function Introduction Charge Active, pre-charge, constant current and constant voltages are the stages of charging mode. The initial charging mode depends on the battery voltage, so active and pre-charge don't happen to every batteries. For charging mode and current, please refer to the paragraphs of charging mode and charging current on page 2 & 3. Tester will stop charging if one of the conditions below was met. 1) Remaining capacity 99% & current intensity = 0 2) Remaining capacity = full charge capacity 3) Current intensity reduce to end charge current when constant voltage charge 4) Remaining capacity reach up the set value Discharge Constant current discharge for double loads Inner load: 0 ~ 1000mA, adjustable continuously via Battery Manager External load: 0mA, 500mA, 1000mA, 1500mA, 2000mA, five gears with dip switches offered Tester will stop discharging if one of the conditions below is met. 1) Remaining capacity set value 2) Voltage set value 3) Current intensity reduce to zero Remarks: Many batteries can not measure exact current intensity, which cause an else current value appears after you set a value. However, the actual discharging current is the same with your set value. Test Testing time is 12 seconds and the purpose is to check both the charging and discharging performances. After finishing test, LED flickers with green color and LCD reports the test result. Normal: Test OK Shown on LCD Abnormal: Test NG Shown on LCD Possible causes and solutions for the abnormal: 1) Cause: battery voltage is too low to discharge Solution: try to charge the battery to raise voltage 2) Cause: remaining capacity is too full to charge any more Solution: try to discharge the battery to reduce the remaining capacity 3) Bad contact of battery connecting wires 4) Damaged battery 5) Tester trouble Capacity Correction The battery capacity value in the battery management chip will different from the actual capacity after a battery goes through many recycling cycles. It will affect the use of the battery when the difference reaches a certain degree. Capacity correction is to deep discharge a battery and then fully charge, which will correct the capacity value in the battery management chip. Remarks: Discharging current can be set via Battery Manager. Deep discharge will cause a battery losing communication with tester, so battery dropping phenomenon may happen in the discharging process if the end capacity and voltage are set too low. In such a case, active charge will make the battery work again. 50% Capacity CD50%: charge firstly, and then discharge to 50% capacity DC50%: discharge firstly, and then charge to 50% capacity Online Functions Tester can be connected with master machine via a USB port. Users can monitor, control and set parameters via Battery Manager software in the master machine. Monitoring Battery information can be monitored via three windows. 1. Home screen Battery bar and brief information can be read on home screen. 2. Battery detail information window Show smart battery data in real time and the data can be saved and printed in image format. 3. Battery graph window Voltage, current and capacity are traced in curves. Control Battery Manager can control slave machine completely. Right-click menu on the battery bar includes the related commands. Attention All the functions of charge, discharge, capacity correction and 50% capacity are comply with the charging discharging conditions, which are showed on function introduction paragraph in page 4 & 5, so parameters should be set reasonably. Especially, deep discharge will cause a battery losing communication with tester. Others 1. Active cooling 2. Active batteries of zero voltage When a battery is deep discharged, the discharge protection circuit will start up and the voltage in the battery connector will become zero voltage. In this case, an appropriate voltage should be supplied to active the battery. 3. Battery identification Battery information can be read from battery management chip after establishing communication. 4. Intelligent protection Against over-current, over-voltage, over-charge, over-heat and short circuit. 5. Fan Discharging mode: fan startup Other modes: fan startup when temperature above 48 Fan stop working when temperature below 40 6. Trouble alarm LED flickers in red color and current command stops when one of the conditions below happen. 1). There is not current for around 50 seconds when charge. 2). There is not current for around 25 seconds when discharge. 3). Charging time is above 8.8 hours. 4). Discharging time is above 9.9 hours. 5). Suitable for almost all laptop batteries, above 95% Structure Accessories 1).1 * adapter 2). 1 * USB cord 3). 1 * CD 4). 13 * connectors 5). 10 * cables 6). 10 * jumpers 7). 1 * loader Standard Export Carton
Supplier: We mainly engaged in the products of portable power system, lithium battery ups power system, solar power,, system, inverter power, power jumper, jump starter, solar led lights, emergency power bank and other,, energy saving/ environmental protection products.
Services: OEM
Apcáback-ups cs, 300 watts / 500 va, inputá230v / outputá230v, interface port db-9 rs-232, usb includes: cd with software, documentation cd, qty 1 - detachable 1.2 m iec power cord, qty 1 - detachable 1.8 m iec power cord, telephone cable, usb cable, warranty card "output output power capacity:300 watts / 500 vamax configurable power :300 watts / 500 va nominal output voltage :230v output connections :(1) iec 320 c13 (surge protection) (3) iec 320 c13 (battery backup) (2) iec jumpers (surge protection) input nominal input voltage:230v input frequency :50/60 hz +/- 3 hz (auto sensing) input connections :iec-320-c14 inlet Cord length :1.83 meters input voltage range for main operations 196 - 280v input voltage adjustable range for mains operation 160 - 300v " Maximum height:165.00 mm maximum width :91.00 mm maximum depth :284.00 mm net weight :6.32kg shipping weight :7.05 kg shipping height :178.00 mm shipping width :241.00 mm shipping depth :368.00 mm color :beige scc codes 107 31304 01635 6 units per pallet :96.00
Rplt-7200 series lighting towe Product info Linghtinglighting panels per unit6*480w or 4*720w/1000w saa certified robust power led lamps(ac/dc, 50/60hz) Optional colour temperature2100k-5700k Auto startdusk-dawn auto/stop timer Longevity3 years Lumen output261000 Dimensionlength3100mm Width1852mm Height2440mm Hydraulic mast extension10000mm Hydraulic rotationâ±135degrees Trailerheavy duty hydraulic stabiliser legs 4 600mm fold away tow bar for transportingyes Tyre size16inch Mine spec chassicïcabinfuel capacity270litres plastic Number axles2 Wheel chocks4 Fluid bundingyes Generatorengine brand kubota Modeld905 3cylinder in-lined, liquid cooled/z482 2cylinder vertical liquid cooled diesel Fuel consumption1.01l/hr / 0.9l/hr Alternator48v dc brushless alternator, self excitation Power generation5kw/4kw continuous(dc) Electronics/instrument paneltimer controller automatic start and shutdownyes Fail-safe shutdown -high temp, low oil pressure, low voltage Lexzan jump start enabled Jumper cables Sms communicationïstart, stop, fuel usage, telementary Battery isolator Timer shutdown control Jump start receptacleïjump leads Emergency stop