Holysun offers two types of Refrigerated Air Dryer:
1). Air-cooling refrigerated air dryer
Inlet temperature:
Normal inlet temperature: less than 45 celsius degree
High inlet temperature: less than 80 celsius degree
Cooling method: Air-cooling
Ambient temperature: less than 38 celsius degree
Dew point: 2~10 celsius degree
Refrigerant: R-22 /R-134a
Inlet pressure: 0.2~1.0MPa
Pressure drop: less than 0.02MPa
2). Water-cooling refrigerated air dryer
Inlet temperature:
Normal inlet temperature: less than 45 celsius degree
High inlet temperature: less than 80 celsius degree
Cooling method: Water-cooling
Dew point: 2~10 celsius degree
Refrigerant: R-22 /R-134a
Inlet pressure: 0.2~1.0MPa
Pressure drop: less than 0.02MPa
Cooling water inlet temperature: less than 32 celsius degree
Cooling water inlet pressure: 0.2~0.4MPa
Refrigeration compressor ,Suitable for refrigerator, freezer, ice maker, water dispenser, dehumidifier, etc.
Refrigerant type: R290, R600A, R134 series
Cooling capacity: from 40w to more than 1000w
Application: LBP , MBP,HBP
Features: High in quality, competitive in price, Good in after sales service.