1 Summary This specification defines the SUM for high Capacity Alkaline cells LR6 1.1 Type IECLR6 OtherAAE914006 JISAM3 1.2 Reference standard IEC 60086-1 --- Primary Batteries - Part 1: General IEC 60086-2 --- Primary Batteries - Part 2: Physical and electrical specification 1.3 Execution standard GB/T 8897.2 2 Chemistry composition Zinc ,EMD , Potassium hydroxide, Graphite 0.00% Mercury & Cadmium 3. Normal voltage1.5V 4. Average weight: 23.0g 5. Nominal Capacity 2500mAh (condition: 43 load resistance, discharge 4 hours per day at 20+/-2°C, end-point voltage 0.9V ) 6 Electrical performance Test conditionLoad Resistance ( ±0.5%) 3.9©Time0.3s, Temperature20±2ã O.C.V C.C.V Accept Level V V 30 days after delivery 1.55 1.45 45 for 3 months 1.52 1.40 MIL-STD105E?¡AQL=0.4 Normal temperature for 12 Months 1.52 1.40 7 Service Life Test condition: 20±2 and 60±15%RH (Discharge Method) Minimum Average Duration ITEM Load Cutoff 30days 45 for 3 Normal Temperature Time Resistance VoltageV After delivery months for 12 Months 43© 4h/d 0.9 90h 81h 81h 3.9© 1h/d 0.8 390min 361min 361min 10© 1h/d 0.9 18.5h 17 h 17 h (IEC ITEM) 1.8© 15sec/min 0.9 600 Cycles 540 Cycles 540 Cycles 250mA 1h/d 0.8 420min 380min 380min 3.9© 24h/d 0.9 350min 315min 315min (REF ITEM)