ZST-P100 On-line Continuous Temperature Measurement of the Billet End
Overview
The system aims at the continuous temperature detection of the product obtained from the continuous casting machine. The billets and their surrounding environmental factors such as scale, steam, shielding and other factors, are considered in the scheme design and equipment selection. The accurate detection and real-time transmission of temperature during the billets movement are also considered.
The equipment selection
Temperature detection
The billet temperature detection adopts the two-color integrated high-temperature thermometer produced by Wuhan CenterRise M&C Engineering CO., Temperature measurement range: 600C - 1400C; All components are installed in a sturdy housing for continuous measurement. The optimized treatment is taken for the problems that the semi-finished billets are hindered by steam or other particles (scale) in the environment, and the billets movement and the installation limited field of view. It provides fast, real-time monitoring of high temperature billets.
Software
Adopting DataTemp software to remotely set and monitor the measuring equipment. Adopting ScanTemp software to analyze and process the temperature data and eliminate invalid signals. Through the software model, the interference factors such as steam and iron scale can be overcome and the actual temperature of the casting billets can be displayed in real time.
The features
Using Si/Si stack detector, high sensitivity
It is easy to use and has sturdy housing, which meets NEMA-4 standard
Bidirectional RS-485/DP communication (can be networked), supports up to 32 detection sensors at most
With user-defined alarm methods, analog and digital outputs are synchronized
Use protective devices and air cooling devices, can withstand high temperature environment
Accurate measurement of moving targets or targets obscured by dust, smoke and other particles in the atmosphere
Adopt passive cooling apparatus, high cooling efficiency and low maintenance
Use software to remotely set and monitor, analyze and secondary process the data, and optimize occlusion measurement
The parameters
Measurement range 600 1400
Response timw10msc)
Spectral response bicolor
Accuracy �±0.75%
Repeatability �±0.3%
Cooling air pressure >0.5Kpa
Cooling air flow 24L/min
Max.temperature 165
Output signal 485 / DP / 4-20mA
Environment standard NEMA4 IEC529 IP65
Please ask detailed and specific
questions about Pricing, Minimum Order Quantity, Delivery Timelines etc. Detailed Messages
result in prompt responses.