Description Product Standard: ISO 4064 Class B End Details: Flanges as per DIN:2533 RF (PN16) Drilled Features It is dismountable and it can be pulled out easily for repair. The recorder is sealed so that readings are clear. The pressure loss is small and it has big flow capacity. It can be installed vertically or horizontally. Working Conditions Pressure Rating: PN 1.6 (16 Bar) Hyd. Maximum Temperature: 45 C Working Pressure: 1.0 MPa Hyd. Accuracy From minimum flow-rate (Qmin) inclusive, to transitional flow-rate (Qt),exclusive: +5% From transitional flow-rate (Qt) inclusive, to overload flow-rate (Qs), exclusive: +2% (APS Marines & Logistics)