Our Specially created Fire Retardant Plywood delays temperature rise, reduce the evaporation of gases, prevent the oxygen content and flame spread. Fire Retardant Plywood can be used in places where there are chances of catching fire like kitchens, restaurants. Applications: container, buses, trucks, railway, hotels multistoried buildings, offices, shopping mall, cinema hall, pantry cars, kitchen etc. Fire Retardant Treatment : type 1 & type 2 Size : 5.5x2.5 to 10.5x5.5 feet Thickness : 4,6,9,12,18,25 mm 3 Density : 0.65 to 1.20 gm/cm TECHNICAL SPECIFICATIONS (IS:5509:2000) Dimensions BIS Requirements Observation Values 1. Length 2440 + 6 2442mm 0 2. Width 1220 + 3 1222mm 0 3. Thickness 12mm �± 5% 11.80mm 4. Squareness 2mm/1000mm 0.95mm 5. Edge straightness 2mm/1000mm 0.50mm 6. Workmanship & finish As per clause 9.1 to 9.2 Satisfactory Physical properties 3 7. Density 0.60 - 0.65gm/cm 0.64gm/cm 8. Moisture contents 5 - 20% 10.25% 9. Water resistance test Pass standard Excellent Cyclic test :8 hours - 16 hours Boiling : drying 3 Cycles : 10. Mycological Test Pass standard Excellent 11. Static bending strength 2 Along the grain M.O.E. Avg. 5000N/mm 5850 N/mm 2 2 Ind. 4500N/mm 4020 N/mm 2 2 Across the grain M.O.E. Avg. 2500N/mm 3480 N/mm 2 2 Ind. 2200N/mm 2855 N/mm 2 Along the grain M.O.R. Avg. 40 47.80N/mm2 Ind. 36 36.40N/mm2 Across the grain M.O.R. Avg. 20 27.25N/mm2 Ind. 18 20.35N/mm FIRE RETARDANT TESTS IS : 5509 : 2000 12. Flammability 30 Min. 35 Min. 13. Flame penetration 30 Min. 33 Min. 14 Rate of burning 20 Min. 28 Min. (Wt. loss 30 to 70%)